- Phone
-
Address
Room B102, Building 5, No. 1188 Jiangyue Road, Minhang District, Shanghai
Shanghai Lingde Instrument Co., Ltd
Room B102, Building 5, No. 1188 Jiangyue Road, Minhang District, Shanghai
Haier Biosafety Cabinet Tubeless Ventilation CabinetHTF-1500W
Main application: The ductless fume hood has the characteristics of easy assembly, portability, low installation cost, and no requirement for exhaust pipe system. Specifically used for conducting small and medium-sized experiments and routine experimental operations in physics and chemistry laboratories, it is safe, reliable, and easy to operate. It can prevent operators from inhaling toxic, harmful, disease causing, or toxic chemicals during experiments, efficiently purify the air in fume hoods and laboratories, and provide safety protection for experimental personnel. Mainly applicable to universities, government testing units, petrochemical and drug testing institutes, disease control, research hospitals, museums, chemical laboratories, and other laboratories involving the use of chemicals.
Haier Biosafety Cabinet Tubeless Ventilation CabinetHTF-1500WProduct Features:
1. Security system
The filters used have poor adsorption effects on hydrogen, helium, inert gases, methane, ethane, ethylene oxide, carbon monoxide, carbon dioxide, nitric oxide, propylene, acetylene, organic phosphorus compounds, mercury, hydrogen cyanide, radioactive isotopes, etc. Generally speaking, the adsorption effect on gases with a molecular weight less than 36 is not good, and it is not recommended to use such fume hoods. In addition, such fume hoods cannot be used for experiments involving high volatile chemicals, high smoke emissions, strong acid-base, flammable, explosive, and highly toxic substances.
Multiple fault alarms (abnormal wind speed alarm, filter life alarm, abnormal glass door position alarm, UV lamp life alarm, etc.).
Two alarm modes (audible buzzing alarm, flashing light alarm).
2. Air duct system
The workspace adopts an integrated structure, using cold-rolled steel plates that have undergone rust prevention treatment and electrostatic spraying, with good smoothness and corrosion resistance.
Surround the operating area with negative pressure to prevent harmful gases or substances from escaping.
3. Control system
High performance EC backward centrifugal fan, with professional structural design, maximizes the efficiency of the fan and matches performance with energy consumption.
VOC sensors and high-precision wind speed sensors provide real-time monitoring of the operation status of fume hoods and the lifespan of filters.
Intelligent adjustment of fan speed to ensure that the inflow airflow velocity in the working area meets the standard requirements.
4. Human centered design
The UV lamp reservation function improves work efficiency.
The lighting fixtures are installed on the inside of the front cover to avoid direct sunlight to the human eye.
The warning function for filter lifespan less than 10% prompts users to replace the filter in a timely manner.
Integrated workbench for easy cleaning and disinfection.