Welcome Customer !

Membership

Help

Beijing Ruiyuan Hengzhi Technology Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Beijing Ruiyuan Hengzhi Technology Development Co., Ltd

  • E-mail

  • Phone

  • Address

    Langfa Village, Huangcun Town, Daxing District, Beijing

Contact Now

HZ-400DJEx gas moisture analyzer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HZ-400DJEx gas moisture analyzer is a moisture analyzer independently developed by our company. The system consists of a separate instrument unit and a pretreatment unit. The testing system uses P2O5 electrolysis to measure the trace moisture content in the gas. As long as the gas does not contain components that damage the pentoxide coating and cell body, do not undergo polymerization reactions on the electrode, and do not participate in electrolysis reactions, it is suitable for this instrument.

Product Details

HZ-400DJEx gas moisture analyzerIt is a moisture analyzer independently developed by our company. The system consists of a separate instrument unit and a pretreatment unit. The testing system uses P2O5 electrolysis to measure the trace moisture content in gas. As long as the gas does not contain components that damage the pentoxide coating and cell body, do not undergo polymerization reactions on the electrodes, or participate in electrolysis reactions, it is suitable for this instrument.

1. Application areas:
Petrochemical, natural gas, industrial gases, semiconductor industry, drying industry, food industry, power industry, machinery manufacturing, air separation industry, pharmaceutical industry.
2. Instrument features:
Adopting LCD high-definition display screen
Unit volume ratio (PPM/V)
Software features *, friendly human-machine dialogue, comprehensive display of information
Up to 200 sets of sampled data can be saved, and the sampling interval can be set (0-999 seconds)
Stable measurement is achieved without being affected by the composition of corrosive gases, such as hydrogen sulfide, chlorine gas, etc. in the medium gas
3. Technical parameters:
Measurement principle: electrolysis method
Measurement range: 0-100/1000ppm (other ranges can be customized)
Accuracy: ± 5% F.S
Resolution: 0.1ppm
Preheating time: ≤ 3 minutes
Response time: T90 ≤ 15 seconds
Sample gas flow rate: 1500-2500mL/min
Sample gas pressure: 0.05MPa ≤ inlet pressure ≤ 0.5MPa (outlet must be at atmospheric pressure)
Analog output: 4-20mA
Contact capacity: 220VAC, 1A24VDC, 1A
Working power supply: 220VAC ± 10%, 50Hz ± 5%
Working environment: Temperature range of -5 ℃ to+50 ℃; Humidity ≤ 85% RH
Dimensions: 600mm (width) x 1200mm (height) x 450mm (depth)
Hole size: Single table 358mm (width) x 259mm (height)
Pre processed 384mm (width) x 400mm (height)
Explosion proof grade: Exd Ⅱ CT6
Weight: Approximately 45kg in total (measuring unit+pre-processing unit+protective box)
HZ-400DJEx型气体中水分测定仪
4HZ-400DJEx gas moisture analyzerTesting principle:
Electrolysis method test, the electrode absorbs gas moisture, electrolyzes into H2 and O2, and the amount of water molecules can be determined from the consumed current. The electrode is a washable P2O5 electrode, mainly made of a glass rod as the substrate, wrapped with equidistant platinum wire on the substrate, and then installed with a detachable corrosion-resistant material body.
This principle is applicable to various working conditions containing corrosive gases, such as CL2/HCL/H2S/HF, etc.
Note:
If there is a liquid component in the medium, this method cannot be tested
This electrode is also suitable for combustible gases such as CH4 and other inert gases
This electrode is not suitable for gases such as NH3 and other gases that react with H3PO4
5. On site working conditions:
A, pressure
The on-site pressure is about 6 kilograms, which can be adjusted by reducing pressure
B, temperature
The maximum temperature on site is approximately 160 ° C, which can be lowered to below 50 ° C through a spiral tube
C, component
There are corrosive gases such as hydrogen chloride in the measured medium on site, and electrolysis can avoid corrosive interference
D, moisture content
The on-site moisture content is approximately 0-100ppm, and after cooling treatment, the impact on moisture concentration is very small
E, protection
The equipment adopts a flameproof structure
F, Special Ingredients
If there is a liquid substance component in the measured medium, this method of measurement is not supported