HY.YTX-1Type vibrating string earth pressure gauge
1.Overview
HY.YTX-1The vibrating wire type soil pressure gauge isour companyThe variety developed through years of practice and user needs is an ideal, safe, and reliable vibrating wire type soil pressure gauge. The lead out cable of this product has undergone secondary sealing and has strong waterproof ability. Widely applicable for long-term measurement of the compressive stress of soil on building foundations such as earth rock dams, breakwaters, revetments, dock walls, high-rise buildings, pipeline foundations, bridge piers, retaining walls, tunnels, subways, airports, highways, railways, and impermeable wall structures. It is an effective monitoring device for understanding the changes in compressive stress of soil on structures in the soil. After installing temperature measuring accessories (purchased separately), the temperature of the buried points can be measured synchronously.
HY.YTX-1Type vibrating string soil pressure gauge surveying instrument
2.Main technical indicators
model |
HYYTX-1 |
|||||||||
rule grid |
1 |
2 |
4 |
6 |
8 |
10 |
16 |
25 |
40 |
60 |
measurement Fan enclose(MPa) |
0~0.1 |
0~0.2 |
0~0.4 |
0~0.6 |
0~0.8 |
0~1.0 |
0~1.6 |
0~2.5 |
0~4.0 |
0~6.0 |
resolution |
≤ 0.0 8% FS |
|||||||||
Non straightness |
≤ 1.5 % FS |
|||||||||
Comprehensive error |
≤ 2.0 % FS |
|||||||||
Temperature measurement range |
-25~+60 ℃ |
|||||||||
Temperature measurement accuracy |
±0.5 ℃ |
|||||||||
HY.YTX-1Type vibrating string soil pressure gauge surveying instrument
3.Acceptance and storage
3. 1After receiving the instrument, the user should open the box for inspection as soon as possible. First, check whether the quantity, specifications, and packing list of the instrument match. If there are any discrepancies, please contact our company in a timely manner.
3. 2use250VUse a megohmmeter to check if the insulation resistance of the instrument at room temperature is greater than50MΩ,and use609AThe frequency and temperature values of the series vibrating string frequency reading instrument are measured. In general, the temperature value should be the local temperature value,error±0.5℃. The frequency value and the initial frequency value given in the factory inspection certificate should be within ±20HzIf there are any abnormalities in the above matters within the scope, please contact our company immediately to avoid any inconvenience to your use.