Welcome Customer !

Membership

Help

Beijing Zhonghai Huaguang Electric Heat Tracing Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Beijing Zhonghai Huaguang Electric Heat Tracing Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    500 meters north of Gongyi West Bridge, Majiabao West Road, Fengtai, Beijing

Contact Now

HWL2 (Q) - J2-30 Enhanced Parallel Constant Power Electric Tracing Belt

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HWL2 (Q) - J2-30 reinforced parallel constant power electric heat tracing cable quotation price list, quality assurance, how to connect direct sales and wholesale pipeline electric heat tracing cable wiring method, Beijing Zhonghai Huaguang DWL-P explosion-proof electric heat tracing cable is generally used in places with explosion-proof, non anti-corrosion requirements, and low environmental humidity; Explosion proof heat tracing tape is a composite layer of metal shielding mesh on the outer layer of the basic type. This structure of heat tracing tape can effectively eliminate static electricity and resist external mechanical collisions, and is mainly used in places with explosion-proof requirements.

Product Details

HWL2 (Q) - J2-30 Enhanced Parallel Constant Power Electric Tracing BeltProduct Usage

Special electric heat tracing cable for antifreeze of instrument pipelines in chemical plants

All electric tracing cables for lime water, gypsum water, process water, and other gas heating pipelines in the gas vacuum chamber heating engineering system, as well as tracing insulation, anticoagulation, antifreeze, heating, and tracing cables for industrial enterprise pipelines and storage tanks.


3、 Construction of electric heating cable

(1) Design drawings

Before construction, there should be a complete design drawing, which should include the following information:

1. The line number and power supply point are represented by rectangular grids.

2. The required heating cable model and length for the circuit. (Unit: meters)

3. The required length of heating cable per meter of pipeline length (unit: meter) is the winding coefficient.

4. The length of heating cable required for each valve. (Unit: meters)

5. List of supporting materials and accessories for the heat tracing system.

6. List of accessories for temperature control system.

7. List of materials required for construction.

8. Design considering parameters and specifications of insulation materials used.

(2) Preparation work before construction

(A) Pipeline system

1. The pipeline system and equipment have been constructed.

2. The anti rust and anti-corrosion coating has dried completely.

3. The construction specifications for pipeline systems are consistent with those shown in the design drawings.

4. File off all burrs and sharp corners.

(B) Heating cables and accessories

1. Is there any damage or breakage on the surface of the heating cable.

2. The insulation performance of the heating cable is good (the insulation resistance is required to be 20M when tested with a shaking table at 1000VDC).

3. The model and design requirements of the electric heating belt and all accessories are consistent



HWL2 (Q) - J2-30 Enhanced Parallel Constant Power Electric Tracing BeltBasic Parameters


1. Maximum maintenance temperature: refers to the process temperature that the medium inside the pipeline needs to maintain, and generally should not exceed the values specified in this table.

2. Rated voltage: 220VAC

3. Normal insulation resistance: ≥ 20M Ω/100 meters

4. Dielectric strength: 2000VAC/50HZ/1min

5. Long term maximum temperature resistance: 205 ℃

6. Explosion proof mark: Exe Ⅱ T4

7. Protection level: IP56 IP65;