E-mail
sales@meas-elec.com
-
Phone
18328702053
-
Address
Room 1, 4th Floor, Unit 1, Building 4, No. 166 Wuxing Fourth Road, Wuhou District, Chengdu City
Chengdu Hongruitao Technology Co., Ltd
sales@meas-elec.com
18328702053
Room 1, 4th Floor, Unit 1, Building 4, No. 166 Wuxing Fourth Road, Wuhou District, Chengdu City
Chengdu Hongrui TaoHT-LE100 Wall mounted Thermal Conductivity Hydrogen Analyzer
The HT-LE100 thermal conductivity hydrogen analyzer is widely used for measuring hydrogen content in ammonia decomposition and protective atmosphere equipment, as well as for online measurement of hydrogen content in welding and cutting ratio gases; Online monitoring of trace hydrogen content in hydrogenation purification nitrogen generator.

Technical Specifications:
lTest Principle:thermal conductivityprinciple
lDisplay mode:320×240dot matrixLCD
lmeasurement range:05%/30%/50%99.99% H2(Range)optional)
ldivide distinguish rate:0.01%
lmeasurement accuracy:≤±1.0%FS
lheavy again sex:≤±1%FS
lresponse time:T90≤60S
loutputinterface:4-20mA. DC(Non isolated output, load resistance)<500Ω)
05V.DC(Non isolated output, load resistance>)10KΩ)
1Programmable dry contact type passive alarm output,Contact CapacityAC220V/2A
lcontact method:RS232(default) orRS485
lworkpower supply:AC220V±10%50/60Hz,power consumption<30VA
lenvironmenttemperature:-10℃~+50℃
lstoreambient humidity:<90%RH, non condensing
lworkambient humidity:<100%RH, non condensing
lsample gastemperature:0℃~50℃
lsampling method:Through typeOr suction type(Please specify when placing an order)
lSample gas flow rate:400~600mL/min
Chengdu Hongrui TaoHT-LE100 Wall mounted Thermal Conductivity Hydrogen Analyzer
Instrument features:
a.The function of switching between Chinese and English menus is intuitive and convenient to operate;
b.320×240Graphic dot matrixLCDDisplay, delicate and clear;
c.adopt
thermal conductivitysensor,haveHigh testing accuracy、Long calibration interval and long service lifeOther characteristics;
d.The instrument supports multi-point segmented linearitycalibration,satisfyFull rangescopeconcentration valueAccurate measurement;
e.temperatureAnd pressureCompensation,Eliminate temperature and pressure effectsThe impact of measurement accuracy;
f.5000Article HistoryAutomatic data storage function and the ability to access historical data at any time;
g.wall-mountedInstallation is simple and easy to maintain;
h.Built in imported air pump(Optional)Long lifespan and reliable operation;
i.Optional according to user needsRS232(default) orRS485Data communication interface,Can be used with computersOr other digital communication devices directlyPerform one-way or two-way communication.