E-mail
809864503@qq.com
-
Phone
15151915144,13511661871
-
Address
No. 68 Liangchang Road, Jintan District, Changzhou City, Jiangsu Province
Changzhou Huapuda Teaching Instrument Co., Ltd
809864503@qq.com
15151915144,13511661871
No. 68 Liangchang Road, Jintan District, Changzhou City, Jiangsu Province
HPD-5 constant temperature shakerIt is a biochemical instrument that combines temperature control with oscillation function, widely used in fields such as biology and chemistry.
HPD-5 constant temperature shaker
1. Model: HPD-5 (vertical)
2. Cyclotron frequency range (rmp): Start at 40-280rpm/m
3. Cyclotron frequency accuracy (rpm): ± 1
4. Tray size (mm): 330x330mm (single-layer, 250ml * 9)
5. Working size: 400 * 400 * 500mm
6. Dimensions: 480 * 530 * 770mm
7. Timing range (h): 0-9999 minutes
8. Temperature control range (℃): 5-55 ℃ (ambient temperature 25 ℃)
9. Temperature resolution (℃): ± 0.1 ℃
10. Temperature uniformity (℃): ± 0.5 ℃ (at a constant temperature of 37 ℃)
11. Display mode: LCD (LCD screen displays temperature and speed)
12. Oscillation mode: rotary type
13. Motor power: 100W (brushless motor)
-Accurate temperature control: Using digital temperature control technology, the temperature control accuracy can reach ± 0.1 ℃, and the temperature uniformity can reach ± 0.5 ℃. It can be accurately adjusted within the range of room temperature+5 ℃ to 60 ℃ or higher.
-There are various oscillation modes: rotary, reciprocating, dual function (both rotary and reciprocating), etc. The oscillation frequency is usually adjustable within the range of 30-300rpm, and there are also multiple options for amplitude, such as the commonly used Φ 25mm.
-Flexible timing function: The timing range is generally 0-999 hours, and some models can be set to normally open mode to meet different experimental duration requirements.
-Reasonable structural design: The inner cavity is mostly made of stainless steel material, which has good corrosion resistance; Equipped with a universal spring bottle rack, suitable for various specifications of flasks, test tubes, etc; Some models have oxygen replenishment holes to ensure sufficient oxygen replenishment in the constant temperature working chamber.
Notes:
-Placement requirements: It should be placed on a sturdy workbench, in a clean and tidy environment with good ventilation, and the work surface should not be excessively smooth.
-Power requirements: The power socket should have good grounding measures, and the electrical rated parameters should not be less than the requirements of the machine.
-Operation specifications: The speed control should be slowly started from low speed to high speed. It is strictly prohibited to move the machine during normal operation, run it without load for more than 30 minutes, and start it under unbalanced load.