E-mail
1941248666@qq.com
-
Phone
13701021424
-
Address
A-105, No.10 Xinghuo Road, Science City, Fengtai District, Beijing
Beijing Jinshui Zhongke Technology Co., Ltd
1941248666@qq.com
13701021424
A-105, No.10 Xinghuo Road, Science City, Fengtai District, Beijing
1Equipment Composition
IIEquipment principle
The radar current meter measures the surface velocity of the water flow, and the radar water level gauge measures the water depth. By inputting the cross-sectional dimensions in advanceUtilizing HydraulicsThe model calculates the cross-sectional flow rate. Radar flow meters are divided into two types: integrated and split. The integrated type includes a radar water level gauge, a radar flowmeter, and a terminal unit (RTU) integrated into one.
IIIApplication scope
Channels and Rivers
Urban drainage network
Underground rainwater pipe network
Agricultural irrigation
Enterprise pollution discharge
4equipment installation

5Equipment features
• Built in import24GHzRadar speed module and 60GHzRadar water level module.
•CWplaneMicrostrip radar non-contact detectionNo, noAffected by climate, sediment, and floating debris.
Fast and accurate measurement, stable data output, and suitable for high flow rate environments during flood periods.
•IP68Protection level, can be used underground.
Multiple data communication interfaces can be set up to facilitate user system integration.
Combining measurement operation and sleep mode to save energy and reduce consumption.
Designed to prevent internal condensation, waterproofing, and lightning protection, suitable for various outdoor environments.
Small in size, easy to install and maintain.
Built in anti rain interference algorithm, unaffected by rainfall.
Integrated radar flowmeter parameters:
·Flow rate:
·Range: 0.05m/s to 30m/s (depending on water flow conditions).
·Accuracy: ± 1% of the measured flow rate.
·Resolution: 1mm/s.
·Water level:
·Range: 0.05-7m.
·Resolution: 1 mm.
·Accuracy: ± 3mm (± 0.2% of measured water level).
·Traffic:
·Accuracy: ± 2% of the measured flow rate.
·Power supply:
DC7-28V 。
·Interface:
RS232、RS485。
·Communication protocol:
Modbus-RTU。
·Transmission frequency:
24GHz。
·Operating temperature:
-The water temperature ranges from 30 ℃ to 70 ℃.
·Shell material:
Galvanized and stainless steel plates.
·Shell protection level:
IP68。
·Reliability:
MTBF≥25000h。