1HJ 70-2025 Chlorine Calibration Method for High Chlorine COD DissolverProduct Introduction
Determination of Chemical Oxygen Demand in Water Quality Potassium dichromate method(HJ 828-2017)According to regulations, this standard does not apply to chloride ion concentrations greater than1000mg/LDiluted saltwater. When the chloride ion content exceeds1000mg/LWhen,CODThe low allowable limit is250mg/LAccuracy below this value is unreliable. Therefore,HJ 828-2017Not applicable to high chloride ion wastewater. Our company follows industry standards《HJ 70-2025water quality Determination of Chemical Oxygen Demand Chlorine gas calibration method》Designed with guidance based on the actual needs of usersTC-100FType high chlorineCODDissolver, this instrument eliminates the impact of high chloride ion content onCODThe interference measured can be considered as a chloride ion content less than20000mg/LChemical Oxygen Demand in High Chlorine Wastewater(COD)The measuring standard instrument is suitable for wastewater from oil fields, coastal refineries, oil depots, chlor alkali plants, and other industriesCODThe measurement.
IIHJ 70-2025 Chlorine Calibration Method for High Chlorine COD DissolverKey Features:
1. According to the industry standardAccording to the requirements of HJ 70-2025, nitrogen circulation throughout the digestion process meets the technical requirements
2. Equipped with 4/8/10A flow meter (high-end) that can individually control the nitrogen flow rate for each sample, saving nitrogen and improving experimental accuracy
3. Using (4 asbestos heating plates, 8/12Microcrystalline glass heating plate), can be used simultaneously4/8/10A sample and1/2A comparative sample(8-digit none digestion experiment
4. Built in high-power fan, using air cooling technology instead of water cooling, combined with glass burr condensation reflux pipe cooling, effectively saves water and energy
5. Using a specially designed triangular flask for digestion, it can be directly titrated after digestion, making it convenient for experimental personnel to operate
3、 Technical indicators:
1. Anti chlorine interference: 1000~20000mg/L(according toHJ 70-2025 Determination of Chemical Oxygen Demand in Water Quality - Chlorine Calibration Method,Above, please followHJ/T132-2003 experiment)
2. Detection limit: 30mg/L
3. Nitrogen flow rate: adjustable from 5 to 60mL/min
4. Measurement range: ≤ 1000mg/L (greater than dilution)
5. Dissolving time: 2 hours (with a time adjustment amplitude of 10 minutes)
6. Dissolving volume: 250mL
7. Dissolving digit: 4+1 (compared sample)、8 digits、10+2(Comparison sample)
8. Measurement error: ≤ 500mg/L, relative standard deviation not exceeding 5.0%; ≤1000mg/L, The relative standard deviation is not greater than 8.0%
9. Heating device: 5-position: asbestos heating plate; eight/12Position: Microcrystalline glass heating plate
10Work environment:(5~40)℃; Relative humidity<85% (no condensation);
11. Heating power: 5 digits: 1400W;8-bit: 2000W;12Position:2000W(220V,50HZ)
4、 Product configuration
1. Host (4/8)/10A flow meter)1 unit
2. Triangle flask 5/8/12a
3. Condensation reflux pipe 5/8/12branch
4. Grinding mouth air duct bend 4/8/12branch
5. Tracheal tube 4/8/12branch
6. Silicone hose 4/8/12root
7. 1 power cord
8. 1 copy of instruction manual
9. 1 certificate of conformity
10. 1 warranty card