HI9804NEW Multi purpose and Multi parameter Water Quality Comprehensive Laboratory, with complete measurement indicators, allows users to conveniently measure acidity, oxidation-reduction, conductivity, resistivity, salinity (including seawater salinity), dissolved oxygen (including saturated dissolved oxygen, oxygen consumption rate, specific oxygen consumption rate) BOD、 Turbidity, temperature, ammonia nitrogen, cyanide, residual chlorine, total chlorine, fluoride, silicon dioxide, iron, copper
HI9804NEW Multipurpose and Multi Parameter Water Quality Comprehensive Laboratory - On site Monitoring and Vehicle Measurement Special Analysis
|
HI9804NEW Multi purpose and Multi parameter Water Quality Comprehensive Laboratory, based on the current international water quality monitoring standards and requirements, fully utilizes HANNA's new technologies and processes, combined with the actual usage characteristics of Chinese users and China's new water quality monitoring standards in 2006. HANNA in Italy has adjusted the original modular configuration to make it more suitable for rapid on-site monitoring and analysis in various situations. It is equipped with an advanced vehicle mounted portable charging system for monitoring vehicle flow monitoring and analysis, efficient and high-precision measurement and analysis indicators, and has a specialized measurement system in the laboratory; Complete measurement indicators enable users to conveniently measure acidity, oxidation-reduction, conductivity, resistivity, salinity (including seawater salinity), dissolved oxygen (including saturated dissolved oxygen, oxygen consumption rate, specific oxygen consumption rate) BOD、 Measurement of nearly fifty parameter indicators including turbidity, temperature, ammonia nitrogen, cyanide, residual chlorine, total chlorine, fluoride, silicon dioxide, iron, copper, etc. in surface water, groundwater, industrial wastewater, and sewage treatment; It has the characteristics of easy use, flexible configuration, lightweight portability, high measurement accuracy, low price, and stable consumables.
|
Acidity (pH), oxidation-reduction potential (ORP), temperature technical indicators:
Acidity measurement range: -2.0-20.0; -2.00-20.00 pH; -2.000-20.000 pH
Acidity resolution: 0.1; 0.01; 0.001 pH
Acidity accuracy: ± 0.01; ±0.002 pH
ORP measurement range: ± 2000 mV
ORP resolution: 0.1 mV
ORP accuracy: ± 0.2 mV
Temperature measurement range: -20.0-120.0 ℃; -4.0-248.0℉
Temperature resolution: 0.1 ℃; 0.1℉
Temperature accuracy: ± 0.4 ℃; ±0.8℉
|
Conductivity, resistivity, TDS, Salinity technical indicators: Conductivity measurement range: 0-400 mS/cm (actual conductivity 1000 mS/cm); 0.001-9.999 μS/cm; 10.00 -99.99 μS/cm; 100.0-999.9 μS/cm; 1.000-9.999 mS/cm; 10.00-99.99 mS/cm; 100.0-1000.0 mS/cm (automatic range conversion) 电导率解析度: 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm Conductivity accuracy: ± 1% of reading (± 0.01 μ S/cm or 1 word) Range of resistivity measurement: 1-999.9 Ohm · cm; 1.000-9.999 kOhm·cm; 10.00-99.99 kOhm·cm; 100.0-999.9 kOhm·cm; 1.0-100.0 MOhm · cm (automatic range conversion) Resolution of resistivity: 0.1 Ohm · cm; 0.001 kOhm·cm; 0.01 kOhm·cm; 0.1 kOhm·cm; 0.1 MOhm·cm Resistance accuracy: ± 2% of reading (± 1 Ohm · cm or 1 word) TDS measurement range: 0.00-99.9ppm; 100.0-999.9ppm; 1.000-9.999g/L; 10.00-99.99g/L; 100.0-400.0g/L (automatic range conversion) TDS解析度: 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L TDS accuracy: ± 1% of reading (± 0.05 ppm or 1 word) Salinity measurement range: Salinity: 0.01-42.00; Salinity of seawater: 0.00-80.00 (PSU); Percentage salinity; 0.0-400.0% Salinity resolution: 0.1%; zero point zero one Salinity accuracy: calibration point of reading ± 1%
Turbidity technical indicators: Turbidity measurement range: 0.00-99.9; 10.0-99.9; 100-1000 NTU automatic conversion Turbidity resolution: 0.01 NTU (0.00-99.9 NTU); 0.1NTU (10.0-99.9 NTU); 1 NTU (100-1000 NTU) Turbidity accuracy: ± 2% of reading+0.02 NTU Reproducibility: ± 1% or 0.02 NTU of reading EMC deviation: ± 0.05 NTU Calibration method:<0.1, 10, 100, and 750 NTU can be selected for two-point, three-point, or four point calibration
Other technical indicators: Data interface: USB or RS232 interface (choose HI92000 software HI920010 RS232 or USB data cable) Battery type: battery pack Automatic shutdown: User selection: 5, 10, 30, 60 minutes or no shutdown Operating environment: IP67 (excluding colorimetric measurement)
|
|
Ionic concentration technical indicators:
|
|
Code Parameters
|
measurement range
|
resolution
|
precision
|
measurement method
|
Choose reagents
|
|
P1 Aluminum P2 ammonia nitrogen MR P3 ammonia nitrogen LR P4 Bromine P5 residual chlorine LR P6 Total Chlorine LR P7 chlorine dioxide P8 Hexavalent Chromium HR P9 Hexavalent Chromium LR P10 chromaticity P11 Copper HR P12 Copper LR P13 氰化物 P14 Cyanuric acid P15 fluoride LR P16 Calcium Hardness P17 Magnesium Hardness P18 Hydrazine P19 Iodine P20 Iron HR P21 Iron LR P22 锰HR P23 锰LR P24 Molybdenum P25 nickel P26 nitrate nitrogen P27 Nitrite HR P28 Nitrite LR P29 Dissolved oxygen P30 acidity P31 Phosphate HR P32 Phosphate LR P33 Phosphorus P34 Silicon Dioxide P35 Silver P36 Zinc
|
0.00 to 1.00 mg/L 0.00 to 9.99 mg/L 0.00 to 3.00 mg/L 0.00 to 8.00 mg/L 0.00 to 2.50 mg/L 0.00 to 3.50 mg/L 0.00 to 2.00 mg/L 0 to 1000 μg/L 0 to 300 μg/L 0 to 500 PCU 0.00 to 5.00 mg/L 0.00 to 1000 μg/L 0.000 to 0.200 mg/L 0 to 80 mg/L 0.00 to 2.00 mg/L 0.00 to 2.70 mg/L 0.00 to 2.00 mg/L 0 to 400 μg/L 0.0 to 12.5 mg/L 0.00 to 5.00 mg/L 0 to 400 μg/L 0.0 to 20.0 mg/L 0 to 300 μg/L 0.0 to 40.0 mg/L 0.00 to 7.00 g/L 0.0 to 30.0 mg/L 0 to 150 mg/L 0.00 to 0.35 mg/L 0.0 to 10.0 mg/L 6.5 to 8.5 Ph 0.0 to 30.0 mg/L 0.00 to 2.50 mg/L 0.0 to 15.0 mg/L 0.00 to 2.00 mg/L 0.000 to 1.000 mg/L 0.00 to 3.00 mg/L
|
0.01 mg/L 0.01 mg/L 0.01 mg/L 0.01 mg/L 0.01 mg/L 0.01 mg/L 0.01 mg/L 1 μg/L 1 μg/L 10 PCU 0.01 mg/L 1 μg/L 0.001 mg/L 1 μg/L 0.01 mg/L 0.01 mg/L 0.01 mg/L 1 μg/L 0.1 mg/L 0.01 mg/L 1 μg/L 0.1 mg/L 1 μg/L 0.1 mg/L 0.01 g/L 0.1 mg/L 1 mg/L 0.01 mg/L 0.1 mg/L 0.1 pH 0.1 mg/L 0.01 mg/L 0.1 mg/L 0.01 mg/L 0.001 mg/L 0.01 mg/L
|
± 4% ± 0.2 mg/L of reading ± 5% ± 0.05 mg/L of reading ± 4% ± 0.04 mg/L of reading ± 3% ± 0.08 mg/L of reading ± 3% ± 0.03 mg/L of reading ± 3% ± 0.03 mg/L of reading ± 5% ± 0.01 mg/L of reading ± 4% ± 5 μ g/L of reading ± 4% ± 1 μ g/L of reading ± 5% ± 10 PCU of reading ± 4% ± 0.02 mg/L of reading ± 5% ± 10 μ g/L of reading ± 3% ± 0.005 mg/L of reading ± 15% ± 1 mg/L of reading ± 5% ± 0.05 mg/L of reading ± 5% ± 0.11 mg/L of reading ± 5% ± 0.11 mg/L of reading ± 3% of the full range ± 5% ± 0.01 mg/L of reading ± 2% ± 0.04 mg/L of reading ± 8% ± 10 μ g/L of reading ± 3% ± 0.2 mg/L of reading ± 3% ± 2 μ g/L of reading ± 5% ± 0.03 mg/L of reading ± 4% of the reading ± 10% ± 0.05 mg/L of reading ± 4% ± 4 mg/L of reading ± 4% ± 0.02 mg/L of reading ± 3% ± 0.2 mg/L of reading ± 3% ± 0.03 pH reading ± 4% ± 1 mg/L of reading ± 4% ± 0.04 mg/L of reading ± 4% ± 0.3 mg/L of reading ± 3% ± 0.03 mg/L of reading ± 10% ± 0.005 mg/L of reading ± 3% ± 0.03 mg/L of reading
|
Try the Aluminum Spirit Method Sodium reagent colorimetric method Sodium reagent colorimetric method DPD method DPD method DPD method Chlorophenol red method Diphenylcarbazide spectrophotometric method Diphenylcarbazide spectrophotometric method Platinum cobalt colorimetric method Quinoline method Quinoline method Pyridine acid colorimetric method Suspended turbidity method Spadns 法 Calcium magnesium reagent method EDTA method P-dimethylaminobenzaldehyde method DPD method Diazaphenanthrene spectrophotometric method TPTZ method Potassium periodate oxidation photometric method PAN method 硫基醋酸法 colorimetry Cadmium reduction method ferrous sulfate method N - (1-naphthyl) - ethylenediamine photometric method Winkler's method Phenol red method Amino acid method Ascorbic acid method Amino acid method Zadolan method PAN method Zincon method
|
HI93712-01 HI93715-01 HI93700-01 HI93716-01 HI93701-01 HI93711-01 HI93738-01 HI93723-01 HI93749-01 --- HI93702-01 HI95747-01 HI93714-01 HI93722-01 HI93729-01 HI93720-01 HI93719-01 HI93704-01 HI93718-01 HI93721-01 HI93746-01 HI93709-01 HI93748-01 HI93730-01 HI93726-01 HI93728-01 HI93708-01 HI93707-01 HI93732-01 HI93710-01 HI93717-01 HI93713-01 HI93706-01 HI93705-01 HI93737-01 HI93731-01
|
|
Standard Configuration
|
¥ Price
|
|
HI9804New acidity, conductivity, dissolved oxygen BOD、 Salinity, turbidity, multi parameter comprehensive measuring instrument, relevant information
|
40,370.00
|
|
optional accessories
|
|
|
|
HI72911B pH/℃ electrode HI76313 conductive electrode HI76407/4F Dissolved Oxygen Electrode HI76407A/P Dissolved Oxygen Membrane (5 pieces) HI7041S electrolyte HI710042-01 Inductive Charger HI98186-300 BOD dedicated measuring bottle HI98703-58 Colorimetric Plate Lubricant
|
HI731313 glass colorimetric dish HI731333 turbidity specific colorimetric dish HI731318 Color dish cleaning cloth HI98703-11 turbidity correction group HI7004 pH 4.01 Calibration Solution HI7007 pH 7.01 Calibration Solution HI7010 pH 10.01 Calibration Solution
|
HI7031 conductivity calibration solution HI7037 Salinity Calibration Solution HI70300 electrode preservation solution HI92000 data processing software HI920010 data cable HI920010 USB Data Cable HI260207 portable packaging box
|