HI9419 portable multi parameter water quality analyzer

NegotiableUpdate on 03/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The HI9419 portable multi parameter water quality analyzer adopts the T.I.S automatic system to record operation time, location, and other specific operating environment information. At the same time, the data stored in the instrument can be downloaded and output through USB or RS232 interface;

Product Details

HI9419 portable multi parameter water quality analyzer

Italy's Hana has recently launched the HI9419 rapid water quality analyzer, which can monitor 14 water quality indicators. The instrument adopts a 128 × 6 pixel LCD display screen, which can automatically adjust the number size to ensure that all information of the measured parameters (measurement results, units, operation menu, charts, etc.) is fully displayed. Each parameter can be viewed with corresponding help information during calibration and measurement process. For the convenience of monitoring and recording data, HI9419 adopts Hanna's unique T.I.S. name recognition system: using a unique ID code to record data and related information. The HI9419 portable multi parameter water quality analyzer also has powerful GLP function and can be flexibly connected to a personal computer through two modes: USB interface and RS232 interface. The instrument can be used for field measurement, rapid analysis of mobile monitoring vehicles, and specialized measurement analysis in laboratories. It is shock resistant and meets the IP67 waterproof standard. The turbidity/residual chlorine total chlorine uses EPA certified tungsten lamps or LED light sources ISO7027 to ensure measurement consistency and accuracy, especially for low turbidity measurements, demonstrating its superiority. At the same time, the multi parameter sensing electrode can be placed in water for measurement (meeting the IP68 waterproof standard). For the convenience of calibration, HI9419 has a fast calibration function, which can use a calibration solution to calibrate pH, conductivity, dissolved oxygen, and perform 2-4 point or custom calibration on turbidity.


1. The T.I.S automatic system can record operation time, location, and other specific operating environment information, and the data stored in the instrument can be downloaded and output through USB or RS232 interfaces;
2. Does the instrument use a unique CAL CHECK? System. When measuring turbidity, two-point, three-point, or four point calibration can be selected, or custom numerical calibration can be used. The light source system has automatic compensation function and does not require frequent calibration. The instrument can store multiple data including time, data, and new calibration points (turbidity measurement);
3. The memory function can remember all electrode data; The screen adopts a user-friendly interface and displays operation guidance codes at the same time; Can display data curve charts (excluding turbidity and chlorine measurements);
4. Chlorine measurement adopts a unique Cal Check ™ Function, capable of verifying calibration status; Tungsten lamp light source is certified by EPA or LED light source ISO7027, specializing in measuring turbidity and applied to high and low turbidity measurements with high * * performance;
5. Widely used in related industries such as environmental monitoring, sewage and water supply and drainage, tap water, hygiene and epidemic prevention, scientific research and education.


Technical Indicators:

Acidity:Measurement range: 0.00-14.00pH Resolution: 0.01pH * * Degree: ± 0.02pH
Calibration mode: Choose 1, 2, or 3 for calibration; 5-point calibration solution selection (pH 4.01, 6.86, 7.01, 9.18, 10.01)
ORP:Measurement range: ± 2000.0mV Resolution: 0.1mV * * Degree: ± 1.0 mV
Conductivity:Measurement range: 0.000-200.000 mS/cm (actual EC range: up-400 mS/cm)
**Degree: Reading ± 1% or ± 1 μ S/cm
Resolution: Manual mode: 1 μ S/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm
Automatic mode: 1 μ S/cm (0-9999 μ S/cm); 0.01 mS/cm (10.00-99.99 mS/cm)
0.1 mS/cm (100.0-400.0 mS/cm); 0.001 mS/cm (0.000 -9.999 mS/cm)
0.01 mS/cm (10.00-99.99 mS/cm); 0.1 mS/cm (100.0- 400.0 mS/cm)
Calibration mode: Automatic recognition (84 μ S/cm, 1413 μ S/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS:Measurement range: 0-400000 mg/L or ppm * * Degree: ± 1% or ± 1 mg/L of reading
Resolution: Manual mode: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt)
Automatic mode: 1 mg/L (ppm) [0-9999 mg/L (ppm)]; 0.01 g/L (ppt) [10.00 -99.99 g/L (ppt)]
0.1 g/L (ppt) [100.0-400.0 g/L (ppt)]; 0.001 g/L (ppt)[0.000 -9.999 g/L (ppt)]
0.01 g/L (ppt) [10.00-99.99 g/L (ppt)]; 0.1 g/L (ppt) [100.0-400.0 g/L (ppt)]
Electrical resistivity:Measurement range: 0-999999 Ω· cm; 0-1000.0 k Ω· cm; 0-1.0000 M Ω· cm
Salinity:Measurement range: 0.00-70.00 PSU Resolution: 0.01PSU * * Degree: Reading ± 2PSU or ± 0.01PSU
Specific gravity of seawater:Measurement range: 0.0-50.0 σ t, σ 0, σ 15 Resolution: 0.1 σ t, σ 0, σ 15 * * Degree: ± 1 σ t, σ 0, σ 15
Dissolved oxygen:Measurement range: 0.00-50.00 mg/L Saturated dissolved oxygen: 0.0-500.0% Resolution: 0.01mg/L 0.1%
Within the range of 0.0-300.0% * * degree: reading ± 1.5% or ± 1.0% within the range of 300.0-500.0% * * degree: reading ± 3%
0.00-30.00 mg/L * * degree: reading ± 1.5% or ± 0.1 mg/L 30.00-50.00 mg/L * * degree: reading ± 3 mg/L
Calibration mode: Choose 1 or 2 points for 0 or 100% calibration in air
Atmospheric pressure:Measurement range: 450-850 mmHg; 17.72-33.46 inHg; 600.0 -1133.2 mbar; 8.702-16.436 psi;
0.5921-1.1184 atm; 60.00-113.32 kPa ** 度: ±3 mmHg ±15℃
解析度: 0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Temperature:Measurement range: -5.00-55.00 ℃; 23.00-131.00℉; 268.15 -328.15K
解析度:0.01℃; 0.01℉; 0.01K ** 度: ±0.15℃; ±0.27 ℉; 0.01K
Turbidity:Measurement range: 0.00-99.9; 10.0-99.9 and 100-1000 NTU automatic conversion
Resolution: 0.01 NTU [0.00-99.9 NTU]; 0.1NTU[10.0-99.9 NTU]; 1 NTU[100 -1000 NTU]
**Degree: ± 2% of reading+0.02 NTU
Calibration point: Choose 2, 3, 4 points (<0.1, 10, 100, and 750 NTU) or customize calibration
Residual chlorine and total chlorine:Measurement range: 0.00-5.00 mg/L * * Degree: ± 0.02 mg/L @ 1.00 mg/L
Resolution: 0.01 mg/L (0.00-3.50 mg/L); 0.10 mg/L exceeds 3.50 mg/L or above
Calibration point: 1 mg/L standard calibration colorimetric dish
Select supporting reagents: HI93701-01 (residual chlorine), HI93711-01 (total chlorine)

Other technical indicators:
Data interface: USB interface, RS232 interface, and infrared interface
Data storage: Automatically or manually store 60000 samples (with a storage interval of 1-3 hours), and store 200 sets of turbidity, residual chlorine, and total chlorine
Chart display: Can display data curve charts (excluding turbidity and residual chlorine total chlorine)
GLP/backlight: equipped with GLP function and backlight settings
Supporting accessories: HI9828/4 multi parameter combination electrode, HI732313 turbidity, residual chlorine, total chlorine special glass colorimetric dish
Supporting power supply: HI710046 car specific power supply and charger, 8 × 1.5 V AA alkaline battery
Usage environment: 0-50 ℃ * high humidity of 95% (no condensation water)
Application standards: The host meets the IP67 waterproof standard, and the probe meets the IP68 waterproof standard;
Residual chlorine and total chlorine: comply with USEPA method 330.5 and standard method 4500
Turbidity: Complies with USEPA method 180.1 and standard method 2130 B or ISO7027 measurement standards
Automatic shutdown: with automatic shutdown function

Standard Configuration

¥ Price

HI9419 host, electrode, measuring colorimetric dish, calibration group, related materials, portable case

31,900.00

optional accessories

HI769828-0 pH electrode
HI769828-1 pH/℃ electrode
HI769828-2 EC electrode
HI769828-3 DO electrode
HI7698282 Probe Maintenance Kit

HI7042S dissolved oxygen filling solution
HI9828-25 rapid calibration solution
HI92000 data processing software
HI920011 Data Connection Cable
HI710006/8 power adapter

HI93414-11 turbidity correction group
HI731331 colorimetric cup (without lid)
HI98703-58 Colorimetric Plate Lubricant
HI260203 portable packaging box