The hybrid diffuse reflectance spectroscopy (HDRS) in vitro sun protection factor (SPF) testing method complies with the ISO 23698:2024 standard and can provide results for long wave ultraviolet protection factor (UVAPF), sun protection factor (SPF), and critical wavelength (CW) testing, while avoiding ethical and safety issues associated with existing human erythema testing methods.
HDRS Sunscreen Testing SystemPoly602Application fields:
·ISO 23698:2024 Sun Protection Factor (SPF) Measurement Standard
·Clinical testing for static sun protection factor, waterproof sun protection factor (WR SPF), long wave ultraviolet protection factor (UVAPF), and critical wavelength (CW)
·Analysis of Application Methods for Sunscreen Products Used for Technical Personnel Training
HDRS Sunscreen Testing SystemPoly602Product Features:
·Quickly obtain sun protection factor (SPF) and long wave ultraviolet protection factor (UVAPF) results
·A single measurement usually takes only 3-4 seconds
·The sun protection factor (SPF) and in vitro data processing are convenient, and the results are easy to read
·Integrated data processing system with automatic calculation and data report generation functions
·In vitro testing (no skin erythema reaction)
·The spectral output complies with ISO 24442 standard, and the intensity is only a very small fraction (of traditional methods)
·The total energy is below the lower limit of the international UV safety measurement threshold, and no additional protective measures are required for technicians or subjects
·Participants can participate in a mixed diffuse reflectance spectroscopy (HDRS) test every 7 days
·Including laptops and HDRSplus ™ software
·Equipped with visual indicators for system readiness and measurement status
·Small footprint, can try to save space on the experimental platform as much as possible
System Configuration:
·Poly602 HDRS Host
·LS1000 Solar Simulator
·SPF290 UV Transmittance Analyzer
·PMMA test board
·RestAssured Service, Maintenance, and Warranty
Poly602 Technical Parameters:
| HDRS spectral range |
320-400nm |
| Working environment conditions | 15℃ ~ 35℃, Relative humidity below 90% (no condensation) |
| Power requirements |
110-240 VAC,50/60Hz, Maximum 7A |
| communication interface | USB |
| size |
Height: 26.2 centimeters (10.3 inches); Width: 40.6 centimeters (16 inches); Length: 40.6 centimeters (16 inches); An additional 8 centimeters (3 inches) of space needs to be reserved for the tail interface and heat dissipation airflow |
| weight |
15.4 kg |
| optical fiber |
Split fiber bundle (including integrated probe), length: 1.8 meters (70.5 inches) |
| Performance standards |
Compliant with ISO 23698:2024 standard |
| The time required to complete a set of tests |
10 subjects, 8 test products require 8 hours |
| Eye/skin exposure level | Not exceeding the recommended occupational exposure limit |
| Remote collection and control | Including probe, foot switch, and keyboard control functions |