- Phone
-
Address
No. 1137 Chengdong Road, Jiaxing City, Zhejiang Province
Jiaxing Lite Electronic Technology Co., Ltd
No. 1137 Chengdong Road, Jiaxing City, Zhejiang Province
H2 gas detector detector durtexpro Duran Spain
Thin film transistors for explosive gas detectors using catalytic technology.Available formats:RS485 addressable 4-wire connection, compatible with EUROSONDELCO&DURGAS, And it can beThe same cycle.4-20mA 3-wire connection, compatible with any system provided4-20mA input.The detection range is from 0 to 100% L.E.L.Optical indicators for circuit and sensor faultsSelect the gas to be detected through jumper (RS485)Optional programmable alarm relay (4-20mA) and optional output relay (RS485)Silicon Vapor Resistance (HDMS)Available gasMethane - natural gas, hydrogen, butane, propane, heptane, hexane, pentane, methanol, styrene, ethane, ethanol, ethylene, propylene, acetone, ammonia, cyclohexane, cyclopentane, dioxane, butyl acetate, ethyl acetate, acetic acid, isobutanol, isopropanol, decane, benzene, isooctane, methyl ethyl ketone (butanone), nonane, propanol, toluene, xylene, kerosene, propanol, and methyl isobutyl ketone.
For other gases, please inquire about availability.Calibration of a suitable 4-20mA detector in the factory requires prior knowledge of the gas to be detected.DURTEX HC PRO allows the use of jumper wires to select gases for detecting any available gas - the RS485 model also offers a special version for detecting acetylene.
Installation position/heightIn areas where gas accumulates, stay 1.5 meters away from gas appliances to avoid airflow.The coverage area is approximately 16 m2. It is recommended to install at a height30cm from the ceiling: methane, natural gas, ammonia, hydrogen.30 cm above the ground: butane, acetone, ethyl acetate, butyl acetate, acetic acid, isobutanol, isopropanol, benzene, cyclohexane, cyclopentane, decane, dioxane, styrene, ethane, heptane, hexane, ethyl ketone (butanone), nonane, pentane ,Propanol, toluene, xylene, kerosene, propanol, methyl isobutyl ketone, and isooctane.100 cm above the ground: Ethane, ethanol, ethylene, methanol, propane, propylene.180 cm above the ground: acetylenemaintenance, upkeepThe DURTEX HC PRO detector has been calibrated with the target gas at the factory, so there is no need to recalibrate it during installation.Check the DURTEX HC PRO detector at least once a year and perform testing and recalibration according to the installation manual instructionsOperation (if necessary).WarningDo not use hydrogen sulfide, fluorine, chloromethane, trichloroethylene, sulfur dioxide, silicon vapor orSulfuric acid, because the presence of these gases can suppress sensor response or damage.Use wire hoses with the correct cross-section for cable input.Do not immerse the detector in water or any other liquid.Do not drill the detector box, otherwise it will lose its protection level (IP65)DURTEX HC PRO is designed for atmospheres below 100% L.E.L. gas, which is calibrated under normal oxygen conditions.
H2 gas detector detector durtexpro Duran SpainThin film transistors for explosive gas detectors using catalytic technology.