- Phone
-
Address
517, No. 6, Lane 1118, Jintong Road, Putuo District, Shanghai
Shanghai Tiandun Electromechanical Equipment Co., Ltd
517, No. 6, Lane 1118, Jintong Road, Putuo District, Shanghai
Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories: World renowned industrial belts, transmission belts, V-belts, synchronous belts, wide-angle belts, and various other industrial special belts from Japan's Samsung, Hankou, the United States' Gates, and Germany's Obi. We welcome new and old customers to discuss the research and development of high-strength bolts, screws, high and low voltage electrical products for testing, as well as various non-standard synchronous belt pulleys! Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories
上海天顿机电设备有限公司三星高速防油三角带SPA型: SPA732 SPA735 SPA757 SPA760 SPA782 SPA800 SPA807 SPA825 SPA832 SPA850 SPA857 SPA860 SPA875 SPA882 SPA885 SPA900 SPA907 SPA925 SPA932 SPA950 SPA957 SPA975 SPA982 SPA1000 SPA1007 SPA1030 SPA1032 SPA1057 SPA1060 SPA1082 SPA1090 SPA1107 SPA1120 SPA1132 SPA1150 SPA1157 SPA1160 SPA1180 SPA1207 SPA1220 SPA1232 SPA1250 SPA1272 SPA1280 SPA1282 SPA1300 SPA1307 SPA1320 SPA1357 SPA1360 SPA1367 SPA1382 SPA1400 SPA1407 SPA1410 SPA1425 SPA1432 SPA1450 SPA1457 SPA1482 SPA1485 SPA1500 SPA1557 SPA1582 SPA1600 SPA1607 SPA1632 SPA1650 SPA1682 SPA1700 SPA1707 SPA1732 SPA1750 SPA1757 SPA1782 SPA1785 SPA1800 . ..... SPA2650 SPA2682 SPA2762 SPA2782 SPA2800 SPA2832 SPA2882 SPA2900 SPA2932 SPA2982 SPA3000 SPA3032 SPA3082 SPA3150 SPA3182 SPA3282 SPA3350 SPA2750 SPA3870 SPA4000 SPA4050 SPA4100 SPA4150 SPA4200 SPA4300 SPA4350 SPA4400 SPA4450 SPA4500 SPA4525 SPA4550
Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories
The triangle has two types of special core structure and rope core structure, which are composed of four parts: wrapping cloth, top glue, tensile body, and bottom glue. The triangular belt with rope core structure is easy to manufacture, with average tensile strength, low price, and wide application. The triangular belt with special core structure has good toughness and high strength, and is suitable for situations with high rotational speed. Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories
Each model of V-belt specifies the cross-sectional dimensions of the V-belt. The cross-sectional dimensions of A-type V-belt are: top width 13mm, thickness 8mm; B-type V-belt is: top width 17MM, thickness 10.5MM; C-type V-belt is: top width 22MM, thickness 13.5MM; D-type V-belt is: top width 21.5MM, thickness 19MM; E-type V-belt is: top width 38MM, thickness 25.5mm. Corresponding dimensions (width * height): O(10*6)、A(12.5*9)、B(16.5*11)、C(22*14)、D(21.5*19)、E(38*25.5) Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories
SPA2057LW belt, mechanical transmission of SPA2057LW imported V-belt equipment, power equipment, automotive transmission, agricultural machinery transmission, etc. Lw effective length Li inner circumference length
Typical models include: regular V-belt cut SPA2282LW V-belt, SPA2282LW Japan Samsung fan belt
The SIZE section size can be used for the Providable inner perimeter length. The triangle has two types: special core structure and rope core structure, which are composed of four parts: wrapping, top glue, tensile body, and bottom glue. The triangular belt with rope core structure is easy to manufacture, with average tensile strength, low price, and wide application. The triangular belt with special core structure has good toughness and high strength, and is suitable for situations with high rotational speed. Guangri Elevator Door Machine GATES Belt 5M1450 Hitachi UAX Accessories
Loading and unloading of belts. Before installation, first check whether the driving wheel, driven wheel, and tensioning wheel are on the same plane. Generally speaking, when the center distance between two pulleys is less than 1 meter, the allowable deviation is 2-3 millimeters, and when the center distance is greater than 1 meter, the allowable deviation is 3-4 millimeters. If the deviation is too large, it should be adjusted to meet the requirements before installation and tensioning. When loading and unloading, the tensioner should be loosened first, or the infinitely variable speed end disc should be removed first, and the belt should be installed or removed. When the new V-belt is too tight and difficult to install and remove, the pulley should be removed first, and then the V-belt should be fitted or removed before installing the pulley. Hard removal is not allowed. Generally, the V-belt should be disassembled and installed after removing the pulley. The tension of the belt. The tension of the transmission belt is adjusted by the tensioning wheel. If the belt is too tight, it will cause serious wear and tear, and if it is too loose, it is easy to slip, causing serious wear and even burning of the V-belt. When the distance between two wheels is about 1 meter, press the middle of the triangle belt with your fingers and it should descend vertically by 10-20 millimeters. During use, the tension of the V-belt should be checked and adjusted at any time. Belt replacement. After the effectiveness of the V-belt, it should be replaced in a timely manner. If multiple V-belts are used together, if one or part of them are ineffective, the other ones should be replaced at the same time, and new and old belts should not be used together. Cleaning of the belt. When the V-belt is stained with grease, engine oil and other oil stains, it is easy to slip and accelerate the damage of the V-belt. It should be cleaned with gasoline or alkaline water in a timely manner, and cannot be operated with oil. The working temperature of the belt SPA2057LW belt, SPA2057LW imported triangle belt Hitachi elevator GVF-2 door machine belt 3/5M1060JB triangle belt