German WTW Turbidity Analyzer Turb 750IR/Turb 750T
Turb 750Replace the original model:Turb 550/Turb 555
Applications: Water, wastewater, wine, beer, food, livestock/Aquaculture, pharmaceuticals, industry
To comply with the regulations on drinking water supervision, there are2Instrument model:
according toDIN EN ISO 7027-1ofTurb 750IR
according toUS EPA 180.1ofTurb 750T
1Turb 750The series adopts validatedAMCO ClearCalibrate with standard samples and use the measurement window on the small bottle. The instrument comes with an accessory for3Calibration kit for point calibration. The following menu guidance calibration function is available:
1)Default3Point calibration
2)Use2-5Flexible calibration of user-defined calibration points
3)Quick calibration:1Point calibration
4)Setting of calibration interval
5)Storage of Calibration Protocol
IIAMCO ClearAdvantages of standard products
AMCO ClearThe standard product is made of polymer microspheres:
1)Long term stability, no drift (different from formalin)
2)The accuracy between batches is1%
3)The optical components have been optimized separately
4)Can be traced back to Fumalazine
5)Environmentally friendly and non-toxic
6)Easy to use
useAMCO ClearSuccessful calibration of standard samples in one go is crucial forTurb 750Obtaining accurate and reproducible results is necessary.
3、 UseAQAObtain reliable results
1)Easy to clean keyboard
2)AQASupport: Interval, Tolerance, Protocol
3)Direct access to basic functions
4)In the datasetAQAlogo
5)With samplesIDstorage
6)Calibration interval and calibration protocol
7)Data filter for data output
8)Compliant withGLPData Management
4、 UseTurb DataPerform data management
Measurement values and associated calibration protocols, samplesIDandAQAInformation is stored together as a dataset.
Data output can be done through a printer orHyperterminalPress the print button on the super terminal. Alternatively, using the providedPCsoftwareTurb DataIt can be easier to complete:
1)Compliant withGLPData transmission
2)Instrument identification through serial number
3)Username input
4)AdoptingCSVFormat output
5)Export data toExcel
6)Import dataLIMS
5、 Technical parameters
Instrument model |
Turb 750IR |
Turb 750T |
measurement standard |
DIN EN ISO 7027-1 |
US EPA 180.1 |
light source |
Infrared light-emitting diode |
White tungsten filament lamp |
Measurement Mode |
Scattering photometry method(90° Scattered light) |
|
display screen |
Backlit graphic display,160*104pixel |
|
keyboard |
Easy to clean foil keyboard with alphanumeric input options |
|
range |
0-1100 FNU/NTU |
0-1100 NTU |
unit |
FNU/NTU |
NTU |
resolution |
in0.00-9.99 FNU/NTUWithin the range0.01 FNU/NTU in10-99.99 FNU/NTUWithin the range0.1 FNU/NTU in100-1100 FNU/NTUWithin the range1 FNU/NTU |
|
accuracy |
0.01 FNU/NTUOr the ± of the reading2% |
0.01NTUOr the ± of the reading2% in500-1100NTUWithin the range, the reading is ±3% |
reproducibility |
<Reading0.5% |
<Reading1% |
reading modes |
Adopting only reproducibility and reliability checks(IRPC)Program, fast response time, andIRCPSupport rapid settling samples for measurement. |
|
response time |
4second |
7second |
calibration-option |
default3Point standard calibration and use2-5Flexible and rapid calibration of user-defined calibration points |
|
Calibration protocol and interval setting |
yes/yes |
|
AQSsupport |
Calibration protocolAQASigns, calibration marks |
|
data storage |
2500A dataset with calibration protocolAQAlogo |
|
Sample identification |
Enter letters and numbers through the keyboard |
|
Software Update |
passUSB |
|
interface |
RS 232TheUSBThe printer passes throughPCorRS 232 |
|
Instrument storage conditions |
-25-+65℃(13-149°F)Work |
|
Working temperature range |
+5-+55℃(41-131°F) When connecting the power plug, it is+5-+40℃(41-104°F) |
|
comply withGLPofPCsoftware |
Turb Data |
|
Size (height)*wide*Deep) |
about290*190*80mm(11.42*7.48*3.15Inches) |
|
weight |
1.1kg |
|
Calibration standard |
for3Calibration kit for point standard calibration: Long term stable polymerAMCO ClearStandard products,0.02-10.0-1000 FNU/NTU |
|
Colorimetric bottle, sample size |
diameter is28mmSmall bottle, minimum capacity15mlBorosilicate glass, phenolic resin bottle cap, PTFE coated rubber seal. Silicone oil is not required to cover scratches in the measurement program. |
|
Sample conditions |
Sample temperature<70℃(158°F) |
|
power supply |
Wide range power supply commonly used for plugs in Europe, the United States, the United Kingdom, and Australia |
|
certificate |
CE |
|
configuration |
Laboratory turbidity meterTurb 750 IR/TFour sections1.5VAABattery, wide range power supplyUSB-AtoUSB-B miniCable, six empty spaces28mmSmall bottle, bottle cap label for directional marking, calibration kitTurb 430/750 IRorTCloth, quick guide, concise operation manual, with extended manualCD-ROMWithTurb Data PCsoftwareCD-ROMInspection Protocol |
|

(German WTW Turbidity Analyzer Turb 750IR/Turb 750T)