E-mail
stchenxin@163.com
-
Phone
13902218596
-
Address
Room 114, No. 13 Hengshan Road, Longhu District, Shantou City
Shantou Keyi Instrument Equipment Co., Ltd
stchenxin@163.com
13902218596
Room 114, No. 13 Hengshan Road, Longhu District, Shantou City
Gas phase headspace automatic samplercharacteristic:
★ Elegant and elegant rotary injection method, compact in size, does not occupy the injection port, and also allows for manual injection; The heatable airtight needle injection method minimizes sample loss to the greatest extent possible, with no sample dilution and high sensitivity, especially suitable for the determination of trace solvent residues;
★ Using inert gas for purging, there will be no cross contamination of the sample;
★ There is no phenomenon of absorption of certain samples caused by transmission pipelines, nor is there any situation of peak broadening due to excessively long transmission pipelines;
★ The injection volume and injection speed can be adjusted arbitrarily;
Up to six samples can be heated simultaneously, improving analysis efficiency;
★ Heating box with oscillation to accelerate the sample to reach thermal equilibrium time;
Accurate positioning and precise stepper motor ensure that there will be no bending of the needle;
★ Seamless compatibility with various gas chromatographs.
★ New IQ/OQ/PQ support services.
Gas phase headspace automatic samplerApplication scope:
Pharmaceutical industry: solvent residues in drugs, ethylene oxide (EO) residues after disinfection of disposable medical products;
Criminal investigation: detection of alcohol in blood and analysis of drugs;
Chemical industry: solvent residues in coatings, inks, and other products;
Packaging industry: analysis of solvent residues and odor components in packaging materials, organic monomer residues in plastic products, and harmful substance residues such as acetaldehyde in PET polyester bottles;
● Food industry: analysis of beer flavor, analysis of essence, spices and other aromatic smells, and solvent residues in edible oil;
Environmental protection: determination of volatile substances in water (dichloromethane, carbon tetrachloride, etc.), determination of organic volatile compounds in soil;
Power industry: High sensitivity analysis of dissolved gases in transformer oil.
HT200HSpecifications:
| Number of samples | 40 bottles (20ml headspace bottle, 10ml headspace bottle is optional) |
| Injection needle capacity | Standard configuration is 2.5ml, 5ml available for purchase |
| injection volume | Zui can reach as little as 0.01ml |
| Injection speed | Can be set from 0.1 to 100ml/min |
| Injection balance delay | Can be set from 0 to 60 seconds |
| Injection frequency | Can be repeated up to 15 times |
| Injection needle temperature | Can be set from 40 to 150 ℃ |
| Sample heating box | 1. Zui can heat up to 6 sample bottles simultaneously 2. The temperature can be set from 40 to 150 ℃ 3. The heating time can be set from 0 to 23 hours and 59 minutes 4. The oscillation time can be set from 0 to 99 minutes |
| Cleaning gas | Use inert gas (nitrogen or helium) |
| Injection mode | Repeated extraction method, and can be set to repeat up to 15 times |
| compatibility | Collaborate with various atmospheric manufacturers(Agilent,Perkin Elmer,Varian,Shimadzu,ThermoSeamless compatibility, sample tray can be freely changed to the left or right. |
| software | HT-Comsoft-AorClarityChromatography workstation |