Welcome Customer !

Membership

Help

Jinan Qiancheng Analytical Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Gas chromatography dimethyl ether detector

NegotiableUpdate on 02/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Gas Chromatography Dimethyl Ether Detector GC-2020 Dimethyl Ether Detector is a small analytical instrument developed by Jinan Qiancheng Analyzer Co., Ltd. The instrument adopts a TCD detector with a six way valve injection system, integrated circuit control, instrument stability, and simplifies the operation steps of the instrument, making it easy to learn and understand
Product Details

Gas chromatography dimethyl ether detector

1Gas chromatography dimethyl ether detectorsketch
GC-2020 Dimethyl Ether DetectorIt is a small analytical instrument developed by Jinan Qiancheng Analyzer Co., Ltd. The instrument adoptsThe TCD detector is equipped with a six way valve injection system, integrated circuit control, and instrument stability, simplifying the operation steps of the instrument and making it easy to learn and understand
The instrument has a small volume (equivalent to half of the size of a computer host), is easy to carry, and can accurately analyze the needs of a large number of liquefied gas station customers. Through one sampling and injection, it can complete the analysis of liquefied gases such as methane, ethylene, ethane, propylene, propane, isobutane, and n-butane in liquefied gasC5The following gaseous hydrocarbon components (excluding alkynes) are included.At the same time, it can also detect the content of dimethyl ether mixed in liquefied gas;
IIGas chromatography dimethyl ether detectorworking principle
Liquefied gas analysis includes component analysis of liquefied gas and analysis of dimethyl ether and methanol in liquefied gas, excluding alkynes. A gas chromatograph with a thermal conductivity detector is used to separate the components in the sample using a chromatographic column. The area normalization method or corrected area normalization method is used to quantify the percentage content of each component using an external standard method

Attachment: Standard liquefied gas components


name
chemical formula Content (%) name chemical formula Content (%)
methane CH4 0.01-1 isobutene C4H8 0.01-10
ethane C2H4 0.01-1 Butene-2 C4H8 0.01-10
ethylene C2H4 0.01-1 Male-2 C4H8 0.01-10
propane C3H8 0.01-20 1.3 Butadiene C4H6 0.01-5
propylene C3H8 0.01-50 Isopentane C5H12 0.01-5
Isobutane C4H10 0.01-20 N-pentane C5H12 0.01-5
N-butane C4H10 0.01-20 1-Pentene C5H9 0.01-5
N-butene C4H8 0.01-10 N-hexane C6H14 0.01-2

Gas chromatography dimethyl ether detector