△High definition LCD touch screen:This model has added a fully tempered glass touch screen LCD display, which is sturdy, durable, and sensitive to touch. Tempered glass is more corrosion-resistant, solving the problem of traditional LED touch displays in gas chromatographs being insensitive to touch due to contact with organic solvents in corrosive environments for a long time.
Three color LED light groups have been added, synchronized with the anti control system software for a fresh, clear, and aesthetically pleasing display.
△High sensitivity FID detector:FID adopts a wide range logarithmic amplification signal processing to ensure weak signal amplification processing, excessive signal compression processing, and unsaturated signal values.
Realize automatic ignition and shutdown monitoring of FID without manual triggering. The ignition frequency is automatically controlled based on temperature, and the ignition threshold can be set arbitrarily.
The excellent FID detector is superior to the previous generation product, with a detection limit that is almost an order of magnitude higher.
The lower end of the detector is equipped with an integrated insulation box to prevent furnace temperature leakage and achieve higher control accuracy.
Excellent capillary injection system:
The injection port is made of 316L stainless steel material, which optimizes the structure of the injection port. The size of the injection spacer is further optimized, and imported spacers can be directly used for complex samples.
Both quartz liner and liner O-ring can use imported products to ensure no ghost peaks during injection.
△Full EPC pressure and flow control system:
This instrument is equipped with an excellent full EPC pressure and flow control system, and the RS232 interface for network port transmission is suitable for effective connection of system software, improving the automation requirements of the instrument.
The new EPC system uses multiple temperature compensation algorithms and back pressure compensation algorithms to make the accuracy of EPC more reliable and stable than the previous generation, providing more complete gas path process control for achieving chromatographic automation.
Pressure protection method: The carrier gas has pressure protection function,When the gas pressure is below 0.1Mpa, the instrument automatically cuts offPower supply effectively protects the safety of chromatographic column use
● Display mode: 7-inch fully tempered glass touch screen displayIndicator
Communication interface: Ethernet, IEEE802.3 (optional module)Proposed output
● Temperature control area: Eight channel temperature control
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃
● Temperature control range: Room temperature+8 ℃ -450 ℃, with 1 ℃ as theincrement
● Program heating: 33rd order program heating, heating rate0.1-40 ℃/min, with increments of 0.1 ℃, initiallyTermination time range: 0-6000min, with 1min intervalsFor increments
Extreme temperature: maximum protection value of 450 ℃
● 外部事件:8通道外部事件
Injector system: Installation quantity 4, single/double packed column injection systemPIP/capillary injection system (SPL)
Detector system: Installation quantity 4, FID/TCD/FPD/ECDNPD/USD
/PDDID, FID use logarithmic amplification signal, solventPeak unsaturation.
● Sample injector system (optional): valve injection system/liquid automatic sampler
● Pre processing system (optional): Headspace sampler, thermal analyzer, blow dryerScanning and capturing devices, etc
● External system connection: supports one key trigger start and relay conduction
Power supply: 220V 50HZ 2000W
Technical parameters for gas path control of injection system:
SSL diversion without diversion: constant current mode/constant voltage mode/Pulse PIP filling column system: constant current mode/constant voltagepattern
● Gas flow range; 0-1000ml/min(He,H2)
0-200ml/min(N2,AIR,CH4)
● Split ratio: maximum adjustable 7500:1 diaphragm
● Purging: with pressure sensor accuracy: < ± 2%
Repeatability of pressure sensor: < ± 0.15%
Pressure control accuracy: EPC control accuracy 0.001psi
Technical parameters for gas path control of injection system:
FID detector EPC: Gas (H2) 0-100ml/min,
Gas (Air) 0-800ml/min,
Tail blowing (N2/He) 0-100ml/min
TCD detector EPC: carrier gas (H2, He, N2)0-100ml/min
FPD detector EPC: Gas (H2) 0-250ml/min,
Gas (Air) 0-300ml or0-500ml/min
Tail blowing (N2/He) 0-150ml/min
ECD detector EPC: Carrier gas (He, N2) 0-150ml/min
NPD detector EPC: Gas (H2) 0-200ml/min
Gas (Air) 0-500 or 0-300ml/min
Tail blowing (N2/He) 0-100ml/min
AUX auxiliary gas EPC: pressure mode (optional gas resistance), supports3rd order program boost module channel: FID/FPD/NPD/AUX
EPC 3路, TCD EPC 2 路 , ECD EPC 1 路
Input pressure range: 0-150psi Accuracy: < ± 2%
Repeatability: < ± 0.15%