GTYQ-MIC-600 Fixed Gas Detection Alarm

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GTYQ-MIC-600 fixed gas detection alarm is used for 24-hour continuous online monitoring of various gas concentrations on site, temperature and humidity measurement, on-site concentration display, optional sound and light alarm for exceeding standards, and remote signal transmission. Using a 2.5-inch high-definition color screen for real-time display, the main detection principles include gas sensors based on electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and other principles

Product Details

GTYQ-MIC-600 Fixed Gas Detection Alarm

Overview of Fixed Composite Gas Detection Alarm MIC-600:

The MIC-600 series online composite gas detector is used for 24-hour continuous online monitoring of various gas concentrations on site, as well as temperature and humidity measurement. It provides on-site concentration display, optional sound and light alarms for exceeding standards, and remote signal transmission. Using a 2.5-inch high-definition color screen for real-time display, the main detection principles include gas sensors based on electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, and high-precision capacitive digital temperature and humidity sensors from Switzerland. Excellent circuit design and mature kernel algorithm processing. MIC-600 is suitable for detecting gas concentrations in pipelines, confined spaces, and atmospheric environments; Gas leakage and high concentration single gas purity with various background gases such as nitrogen or oxygen. More than 500 types have been tested. The sturdy and durable explosion-proof shell and fluorocarbon paint surface treatment process are suitable for various hazardous locations and highly corrosive environments, and are wear-resistant.


Fixed composite gas detection alarm MIC-600 features:

★ It can simultaneously detect 1 to 6 types of gases, and the units can be freely switched. ★ Diversified communication methods.

Real time monitoring can be achieved through wired or wireless remote transmission, network transmission; Simultaneously output standard bus RS485 (modbus RTU) and 4-20mA standard signal; Optional frequency output of 200-1000Hz, Hart protocol signal, 1-5V output, wireless transmission (2-5 kilometers or unlimited distance); Compatible with secondary instruments, data acquisition modules, PLC, DCS systems, and capable of driving related equipment. The optional MIC2000 controller can monitor 1000 detectors simultaneously.

★ Infrared remote control.

Equipped with an infrared remote control as standard, one click operation can be performed through the function keys of the infrared remote control, which can achieve cover free operation in dangerous situations, such as modifying alarm points, concentration calibration, zero calibration, noise reduction, factory reset and other functions.

★ Rich human-machine interface.

2.5-inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage and other information; The menu interface uses high-definition simulation graphics to display the function names of each menu.

★ Large capacity data storage function, supporting multiple storage methods.

Standard 100000 data storage capacity; Optional SD card storage function, supporting real-time storage, timed storage, or only storing alarm concentration data; Supports viewing and deleting data locally, and can also be uploaded to a computer through RS485 interface for data analysis or printing.

★ High temperature gas detection (optional).

Optional high-temperature sampling and cooling filter handle or high-temperature and high humidity pretreatment system can detect flue gas at a temperature of 1300 degrees. Gas detection at other temperatures can be customized.

★ Three display modes can be switched.

Simultaneously display multiple gas concentrations, with large font circulating to display the concentration of a single channel gas, and real-time curve display.

★ Graphic display

  Reflect the trend of gas concentration changes over a period of time in the form of a curve.

The data recovery function allows for partial or complete recovery, eliminating any worries caused by misoperation.

High precision temperature and humidity measurement (optional).

● Multiple alarm methods, with multi-dimensional three-dimensional indication of alarm status during alarm.

Includes: 3 sets of relay switch outputs, sound and light alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.

Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm.

● Misoperation recognition function: automatic recognition and prevention of concentration calibration misoperation, which can avoid adverse effects caused by human factors.

● Zero point automatic tracking, long-term use is not affected by zero drift.

Multi level calibration of target points ensures the linearity and accuracy of measurements.

The Chinese and English interfaces are selectable.

Wide operating temperature: -40~+70 ℃, supports temperature compensation.

● Logging records calibration logs, maintenance logs, fault records, fault resolution strategies, sensor lifespan expiration reminders, and next concentration calibration time reminders.

● Intrinsic safety circuit design, explosion-proof, with secondary lightning protection and anti-static capabilities. Meet national standards and resist high-intensity pulse surge current impact. It has anti reverse connection function. Compliant with EMI and EMC standards.


 Fixed composite gas detection alarm MIC-600 parameters:

Detecting gases: composite gases (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex),

Optional: Can simultaneously detect any 4-6 gases and temperature and humidity

Detection range: CO (0-1000ppm), H2S (0-1000ppm), O2 (0-30% Vol), Ex (0-100% LEL), other ranges can be customized

Resolution: CO (0.1ppm), H2S (0.01ppm), O2 (0.01% Vol), Ex (0.1% LEL), higher resolution can be customized

Detection principles: electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoionization, depending on gas, range, on-site environment, and user requirements

Sensor lifespan: electrochemical principle 2-3 years, oxygen 2 years or 6 years optional, infrared principle 5-10 years, catalytic combustion 3 years, thermal conductivity 5 years

Temperature detection: -40 ℃~+120 ℃ (optional), humidity detection: 0-100% RH (optional), resolution: temperature 0.1 ℃, humidity: 1% RH

Detection accuracy: ≤± 2% F.S (within the full range ≤ 2%), temperature 0.5 ℃, humidity: 3% RH, higher accuracy can be customized

Working mode: fixed installation, online detection, diffusion measurement, pipeline, circulation, pump suction optional

Installation methods: pipeline type, wall mounted type. The working pressure of pipeline type is atmospheric pressure ± 30%. If it exceeds the range, it needs to be depressurized

Response time: T90 ≤ 20 seconds

Recovery time: ≤ 30 seconds

Output signal: Bus based RS485 (RTU), optional three (four) wire system 4-20mA, 0-20mA, 1-5V, 0-5V, 0-10V, wireless transmission

Alarm mode: on-site sound and light alarm (optional), default 1 channel, optional 3 passive contact (dry node) outputs, three-level alarm, alarm points can be set

Working environment: -40 ℃~+70 ℃

Sample gas temperature: -40 ℃~+70 ℃ (conventional), optional: -40 ℃~+400 ℃, -40 ℃~+800 ℃ (up to 1300 ℃)

Relative humidity: ≤ 10-95% RH (conventional) for non condensing occasions, optional: 10-99% RH for high temperature and high humidity occasions, when ordering

Please note that a preprocessing system is required

Working voltage: 12~30V (DC, standard power supply for a single device is 24V, 1A or greater DC switching power supply)

Power reference: A 24V, 2.1A switch power supply can drive 40 toxic gas detectors or 15 flammable and infrared gas detectors

Explosion proof form: Explosion proof Exd Ⅱ CT6

Connection cable: Choose a three core shielded cable for 4-20mA, a four core shielded cable for RS485, and a single wire diameter of ≥ 1.5mm when the distance exceeds 1000 meters; the shielding layer is grounded

Protection level: IP66 waterproof splash and short-term rain. For long-term rain, a rain cover should be selected or a shell without display should be chosen or specified when ordering

Dimensions: 210 × 170 × 85mm

Weight: 1.8Kg

Optional accessories: wall mounting bracket, mounting bracket fixed on the pipeline (four branch, six branch), stainless steel threaded welding seat for pipeline installation

(Pipeline size should be specified, such as DN50, DN15...), room temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature and high humidity and high dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large capacity SD storage card, rain cover, 24VDC or 220AC sampling pump (sampling distance of 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switch power supply.

Accessories required for computer monitoring: free upper computer software, RS485/RS232 converter, USB/RS232 conversion cable for laptops without RS232 interface, and TCP/IP converter for network transmission

Application scenarios: Petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, and all other applications that require fixed installation and online detection of gas concentration


project parameter
gas detection 1-6 types
Product features 1. 1-6 gases+temperature and humidity
2. Composite gas detection
3. High precision
4. Equipped with record storage, standard configuration includes 100000 records, and can be equipped with a 16GB memory card
5. Three wire system 4-20mA output
6. RS485 output
7. Explosion proof level: Explosion proof level: Ex db IIC T6, Ex ia IIC T6
Testing Scope 0-1、10、100、1000、5000、10000、50000ppm, 0-100%LEL,0-5%Vol、30%Vol、100%Vol, Other ranges are optional, and the range is determined by the usage scenario and detection purpose
resolution 0.1%LEL(0~100%LEL)
typical accuracy ±2%(F.S)
Detection method Diffuse measurement, available in pipeline, flow, and pump suction types
display screen 2.5-inch high-definition color screen
working power supply DC24V
Maximum Power Consumption Nothing
working environment Typical value: -20~+55 ℃
Limit value: -40 ℃ to+70 ℃
Humidity: 10-95% RH
data storage Temporarily not supported
Print function Nothing
signal output Bus based RS485 (RTU), three wire system 4-20mA
alarm method Sound and light alarm, 1-3 sets of relay dry contact output, optional sound and light alarm light
Fall alarm Nothing
wireless transmission Optional: LoRa/433M/4G/NB IOT
Dimensions: L * W * H 260 × 180 × 90mm (L × H × W) atmospheric chamber
260 × 230 × 90mm (L × H × W) atmospheric chamber with lamp
240 × 180 × 90mm (L × H × W) conventional gas chamber
240 × 230 × 90mm (L × H × W) conventional with light
weight Atmospheric chamber 2.4Kg/2.9Kg
Conventional chamber 2.2Kg/2.7Kg
protection level IP67
Standard Appendix Instruction manual, certificate of conformity, warranty card, infrared remote control, outer packaging box
Optional accessories 1. Integrated sound and light alarm, split sound and light alarm, 220V-24V DC stabilized power supply, accessories for computer monitoring: upper computer monitoring software (capable of simultaneous video monitoring), RS485/RS232 converter, USB/RS232 conversion cable, TCP/IP converter 2 Optional: Room temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature, high humidity and high dust pretreatment system


GTYQ-MIC-600固定式气体检测报警器