Welcome Customer !

Membership

Help

Wuhan Huatu Gaodian Electrical Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Wuhan Huatu Gaodian Electrical Technology Co., Ltd

  • E-mail

    2144462909@qq.com

  • Phone

    18963954537

  • Address

    Building B, Yuanyuan Xin Industrial Park, Huanhu Middle Road, Dongxihu District, Wuhan City

Contact Now

GOZ-ZGS-60kV/3mA Portable DC High Voltage Generator

NegotiableUpdate on 12/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The GOZ-ZGS-60kV/3mA portable DC high voltage generator is the latest research, design, and manufacturing product based on the requirements of the Chinese industry standard ZBF 24003-90 "General Technical Conditions for Portable DC High Voltage Generators". It is a new era technology product - portable DC high voltage generator. It is suitable for conducting DC high voltage tests on equipment such as zinc oxide lightning arresters, magnetic blow lightning arresters, power cables, generators, transformers, switches, etc. in power departments, industrial and mining enterprises, scientific research units, railways, chemical industries, power plants, etc

Product Details

GOZ-ZGS-60kV/3mA Portable DC High Voltage Generator

GOZ-ZGS-60kV/3mA Portable DC High Voltage GeneratorIt is a new generation portable high-voltage detection instrument designed and manufactured according to the Chinese power industry standard DL/T848.1-2004 "General Technical Conditions for High Voltage Test Equipment Part 1: DC High Voltage Generator", specifically used to detect the electrical insulation strength and leakage current of power devices. The high voltage generator adopts a high-frequency voltage doubling circuit, applies * PWM pulse width modulation technology and voltage current dual loop feedback technology to improve the power supply adjustment rate and load adjustment rate, resulting in high voltage stability and low ripple. Using imported high-power IGBT devices and their driving technology to eliminate switch interference and achieve high quality and portability of high-voltage generators. Selecting imported high-frequency and high-voltage rectifier diodes makes the voltage doubler more compact and lightweight, improving the overall efficiency of the machine. According to the theories of EMI electromagnetic interference and EMC electromagnetic compatibility, measures such as shielding, isolation, and grounding are adopted to enhance the safety of the entire machine and withstand rated voltage discharge without damage. The instrument has complete protection functions, including zero protection, overvoltage protection, overcurrent protection, and breakdown protection. The protection circuit uses nanosecond level dedicated sensors, which act quickly and reliably, effectively ensuring personal and equipment safety. The overvoltage setting uses a digital dip switch, which is easy to operate and has high setting accuracy. Add an intelligent high-precision 0.75U function button to facilitate the testing of zinc oxide lightning arresters. The high-voltage generator adopts an integrated design scheme: the double pressure cylinder and the host are placed in the same chassis, combined with new technology and the use of new components, to achieve the advantages of small size, high power, light weight, easy operation, safety and reliability, and high power output quality. It is an ideal testing instrument in the high-voltage testing industry.

Specifications

Technical Specifications

60/2

100/3

120/2

120/5

180/2

200/2

200/5

100/200

3/2

200/300

3/2

Other

Grade

Output voltage (kV)

60

100

120

120

180

200

200

100/200

200/300

600-800kV and other contracts

Customized.

Output current (mA)

2

3

2

5

2

2

5

3/2

3/2

Output power (W)

120

200

240

260

360

400

500

400

600

Charging current (mA)

3.0

3.0

3.0

3.0

3.0

3.0

4.5/3.0

4.5/3.0

4.5/3.0

Chassis weight (kg)

4.3

4.3

4.3

4.3

4.3

4.4

4.5

4.5

8.1

Height of pressure doubling cylinder (mm)

Φ80

×500

Φ80

×620

Φ80

×770

Φ80

×770

Φ110

×770

Φ110

×770

Φ110

×820

Φ110

×800

Φ110

×1350

Double pressure weight (kg)

6.3

6.8

6.8

7.2

7.2

7.2

7.6

7.5

12.6

High voltage polarity

Negative voltage polarity, zero voltage start, continuously adjustable.

working power supply

AC 220V±10%; 50Hz

Voltage measurement error

1.0% (full degree) ± 1 word, maximum resolution 0.1% kV

Current measurement error

1.0% (full scale) ± 1 word, maximum resolution 0.1% uA

Overvoltage setting error

≤1.0%

0.75Switching error

≤0.5%

Ripple coefficient

≤1.0%

Voltage stability

Random fluctuation, ≤ 0.5% when the power supply voltage changes by ± 10%

working method

Intermittent use; Rated load for 30 minutes; 1.1 times rated voltage usage: 10 minutes

ambient temperature

-15℃~50℃

relative humidity

When the temperature is 25 ℃, not more than 90% (no condensation)

altitude

Below 2500 meters