GLC400 mining intrinsic safety open channel flowmeterIn product design and manufacturing, full consideration should be given to meeting the needs of measuring or monitoring the total discharge of various open channels in coal mines and other explosive hazardous working environments. Use intrinsically safe power supply that meets the explosion-proof standards for underground power supply. A device used for measuring or monitoring the total discharge of various open channels in coal mines and other explosive hazardous work environments, and the measurement results are not affected by water quality.
GLC400 mining intrinsic safety open channel flowmeterproductMain technical indicators
1. Working voltage: 14.0V~25.0V.DC.
2. Working current: ≤ 150mA.
3. Measurement range and error:
(1) Liquid level measurement range: 0.000m to 3.000m;
(2) Liquid level measurement resolution: 1mm;
(3) Liquid level ranging accuracy: ± 0.3% FS;
(4) Flow measurement range: (5.40-400.00) m ³/h;
(5) Basic flow error: ≤± 5%.
4. Interface configuration: It has 1 power and frequency signal output interface, and 1 485 communication interface (reserved).
5. Explosion proof type: mining intrinsic safety type.
6. Protection level: IP65.
7. Explosion proof mark: Exib I Mb.
8. Dimensions: 270mm × 170mm × 125mm.
9. Whole machine weight: ≤ 3.2Kg.