1GJG intelligent storage cabinetOverview:
In the domestic power industry, insulation tools are widely used for live working or operation. The insulation performance of insulated tools decreases after being dampened, posing a serious threat to the safety of maintenance personnel. The existing measures are to use wooden or iron cabinets or insulated tool storage rooms for the storage or preservation of insulated tools. Wooden and iron tool cabinets do not have a long-term and constant moisture-proof effect, and are prone to moisture. However, this type of warehouse requires a large investment, high energy consumption, and a slow drying process, especially for units with few insulated tools, and there is no need to establish an insulated tool warehouse.
Our company's intelligent drying and dehumidification safety tool cabinet effectively solves the above problems and has been welcomed by a large number of users.
The intelligent drying and dehumidification safety tool cabinet is made of high-quality steel plates that are rolled and molded as a whole. The overall design adopts the style of modern industrial control panel cabinets, with surface spraying and sealing that meets the protection level of EN60529/IEC529 standard - IP5 level; The front is a glass observation door, which is convenient for observation and equipped with door controlled lighting. On the right side of the door, there is a display and control operation panel (GJG-3/4 type), which displays the temperature, humidity, and equipment operation status inside and outside the cabinet in real time. There are four universal wheels and positioning screws installed at the bottom of the cabinet; There are four hanging cups on the top of the cabinet for easy transportation.
IIGJG intelligent storage cabinetProduct specifications and models (height x width x depth) Length unit: mm
SG intelligent storage cabinet
| model | Specifications (height x width x depth) | Internal net height | Working Voltage | Dehumidification power consumption | electric heating power | Main functions |
| Ordinary safety tool cabinet GJG-I | 2000×800×450 | 1900 | ----------- | ----------- | ----------- | Placement, moisture-proof, dust-proof |
| Ordinary safety tool cabinet GJG-II | 2000×1100×600 | 1900 | ----------- | ----------- | ----------- | Placement, moisture-proof, dust-proof |
| Ordinary safety tool cabinet GJG-III | 2400×1100×600 | 2240 | ---------- | ----------- | ----------- | Placement, moisture-proof, dust-proof |
| Intelligent Security Tool Cabinet GJGZ-I | 2000×800×450 | 1750 | AC220±V10% | ≤150W | ≤800W | Heating, dehumidification, temperature control, humidity control |
| Intelligent Security Tool Cabinet GJGZ-II | 2000×1100×600 | 1750 | AC220±V10% | ≤150W | ≤800W | Heating, dehumidification, temperature control, humidity control |
| Intelligent Security Tool Cabinet GJGZ-III | 2400×1100×600 | 2150 | AC220±V10% | ≤150W | ≤800W | Heating, dehumidification, temperature control, humidity control |
| Intelligent Security Tool Cabinet GJGZ-IV | 2400×1100×600 | 2240 | AC220±V10% | ≤150W | ≤800W | Heating, dehumidification, temperature control, humidity control |
| Extended GJGK- | as needed | as needed | as needed | as needed | as needed | as needed |
SG intelligent storage cabinet
Attachment: The intelligent drying and dehumidification safety tool cabinet can use intelligent digital temperature sensors as needed, with specific indicators as shown above:
Temperature sensor measurement range: -50 ℃+125 ℃ Humidity sensor measurement range: 0-95% RH
Temperature sensor measurement resolution: 0.625 ℃ Humidity sensor measurement resolution: 0.1% RH
Temperature sensor measurement accuracy: ± 0.1 Humidity sensor measurement accuracy: ± 4% RH (no calibration required)
SG intelligent storage cabinet
Application scope of intelligent drying and dehumidification safety tool cabinet:
Widely used in various voltage levels of substations, centralized control stations, line work areas, and customer service centers of power companies, and adapted to use in different temperature and humidity regions.
Product composition:
This project is a live working safety equipment with a temperature and humidity control system as the core and storage devices; The electrical cabinet, computer and control system, and insulation tool storage device are composed of components.
Product functions and features:
1. Provide a suitable storage environment for insulation tools, keeping them dry and meeting the requirements of the national standard for insulation tool storage environment (GB/T18037).
2. Insulated rods, voltage testers, grounding wires, insulated gloves, insulated boots, safety belts, gas masks, insulated ropes, insulation barriers, shielding suits and other tools and supplies can be stored simultaneously to achieve comprehensive utilization.
3. Choose different internal structure assembly methods according to different placement needs and use them appropriately; Select different specifications of products according to the different sizes of insulated teeth to meet the placement needs.
4. It has the function of tool removal without condensation.
5. Capable of timely dehumidification and drying of insulation tools in a cost-effective and energy-efficient manner, meeting the needs of rapid reuse.
6. The product adopts scientific adjustment algorithms and independent temperature and humidity limit control circuits, which can implement limit alarm, automatic setting, automatic power-off and other control functions, and has the function of manual and automatic integration.
7. It has the function of identifying and classifying insulation tools: by identifying and classifying insulation tools of different models, it can avoid safety accidents caused by picking them up incorrectly, and effectively manage insulation tools of different voltages;
8. It has comprehensive functions of dust prevention, damage prevention, and moisture prevention.
Notes:
For safe use, the cabinet should be grounded and equipped with leakage protection and overheating protection devices. The insulation strength between the power input terminal and the cabinet should be ≥ 5M Ω, and the AC withstand voltage should be 2000V/2min.