| Product Features |
High reliability, certified by the National Relay Protection and Automation Equipment Quality Supervision and Inspection Center;
The display operation module and protective body are installed separately, which is more suitable for miniaturized drawer unit cabinets;
Installation of display operation module with holes, installation of protective main body 35mm guide rail or fixed installation with screws;
Dot matrix Chinese character LCD display, intuitive display, easy operation;
The following functions can be selected in any combination:;
Can provide 16 types of protection, with accurate and reliable protection actions;
High precision measurement of various power parameters;
Featuring multiple startup control functions and multiple control modes
Up to 2 analog outputs, with programmable output objects;
1-channel analog input measurement and protection;
Up to 12 switch inputs;
Up to 5 relay tripping, alarm, and control outputs;
Event recording function with a resolution of 2ms;
Equipped with a small through core current transformer;
No need to equip with anti shaking module, achieve shaking self starting function;
Motor statistical information;
Equipped with dual communication interfaces, MODBUS-RTU communication protocol, Profibus DP protocol (conversion);
Multi button panel for data query, protection parameter setting, and motor start/stop operation;
Equipped with a small through core current transformer.
| Product Selection |

remarks:
1. The standard function of GC-DB300 is full measurement, with standard protection, 1 switch input, 3 relay outputs (trip and alarm), no display, no communication.
2. Standard protection: Short circuit protection, locked rotor protection, timed overload protection, inverse time overload protection, light load protection, grounding protection, current imbalance protection, long start-up time protection, phase loss protection, process interlocking; Protection, overvoltage protection, undervoltage protection, and phase sequence protection.
3. ② Optional. If the suffix option is not specified, it means that the function is not needed. For example, if only GC-DB300 is specified, it means that only the standard features of GC-DB300 are selected.
4. When selecting, indicate the voltage level, with 380V and 690V options available.
5. When selecting the - K start control function, 5 switch inputs and 4 relay outputs are required
6 GC-DB300-60-D-TQKS-5DI-4DO-C1-AO-380, Indicating that it comes with standard functions, split display, tE protection, self starting due to shaking, 5-way switch input, 4-way relay output, 1-way 485 communication, and 1-way analog output. It needs to be started for control, and a 60A through core transformer with S0E event recording is selected. The line voltage is connected to 380.
| TECHNICAL INDEX |
| Installation method | Installation of display operation module with holes, installation of protective main body 35mm guide rail or fixed installation with screws; |
| INPUT | Current 1A, 5A, 7A, 10A, 25A, 60A, 110A, 160A; Voltage 220V/380V, 380V/1660V; |
| Standard protection | Short circuit, locked rotor, definite time overload, inverse time overload, undervoltage, overvoltage, phase sequence, underload, grounding, three-phase current imbalance, phase failure, protection for long starting time, process interlock tripping; |
| Extended protection | Leakage, tE time protection, analog input protection; |
| Action time |
Quick break time: < 60ms; Time limit: 0s~3s < 60ms; Within the range of 3s to 99.9s, not exceeding 2% of the set value; Inverse time limit: 0s~2s < 100ms; Do not exceed 5% of the theoretical value for more than 2 seconds; |
| Action fixed value | Current: ± 50mA or ± 3% of the fixed value; Voltage: ± 2V or ± 3% of the fixed value; |
| Measurements | Various parameters such as current, voltage, power, power factor, frequency, and electrical degree; |
| accuracy class | Current and voltage level 0.5, power level 1, active energy level 1; |
| Switching input | Maximum 12 channels, internal power supply for starting, stopping/resetting, local/remote, process interlocking, and general switch status display |
| Relay | Up to 5 channels, optional normally open or with a set of normally closed nodes, used for tripping, alarm, remote control output, with a capacity of 250Vac/5A, 30Vdc/5A |
| Event record | 64 entries, with a constant time scale, expandable recording quantity, and a resolution of up to 2ms; |
| start control | Direct start, bidirectional start, star/delta start, self coupling voltage reduction start; |
| control mode | Panel control, local control, DCS remote control, communication control, shaking power self starting function; |
| analog output | Up to 2 channels of 4-20mA output, internally active, with an output load of 500 ohms; |
| analog input | 1 channel 4-20mA input; |
| display | 4-line dot matrix Chinese character LCD screen with backlight to display measurement data, protection status, on/off status; |
| key | Press the six buttons to query data and set parameters; |
| Communication Port | Up to 2 communication channels, MOBUS-RTU protocol, Profibus DP protocol; |
| Baud rate | 2400~19200bps; |
| Working power supply | 85- 265VAC 100-300VDC; |
| Overall Power Consumption | <5VA; |
| power-frequency withstand voltage | Input output power supply AC2kV/1min; |
| insulation resistance | >50MΩ; |
| Impulse Voltage | 5kV (peak), 1.2/50uS; |
| Electrical fast transient burst immunity | GB/T 14598.10(IEC60255-22-4); |
| Surge immunity | GB/T 14598.18(IEC60255-22-5); |
| electrostatic discharge | GB/T 14598.14(IEC60255-22-2); |
| Radio frequency electromagnetic field radiation immunity | GB/T 14598.9(IEC60255-22-3); |
| Immunity to Conducted Disturbances Induced by Radio Frequency Fields | GB/T 14598.17(IEC60255-22-6); |
| Power frequency immunity | GB/T 14598.19(IEC60255-22-7) ; |
| Vibration wave immunity | GB/T 14598.13(IEC60255-22-1); |
| Conducted emission limit test | GB/T 14598.16(IEC60255-25); |
| Radiation emission limit test | GB/T 14598.16(IEC60255-25); |
| operation temperature | -20-70℃; |
| storage temperature | -40-80℃; |
| Relative temperature | 5-95%RH, No condensation. |
| Main body dimension diagram |

| Wiring Terminal Diagram |