| Product characteristics |
Equipped with remote communication function, the RS485 communication interface is electrically isolated from the inside of the device, and a lightning protection circuit is designed;
Support DL/T645-2007; Support MODBUS-RTU communication protocol
Can operate continuously for a long time, achieving measurement and control of power system parameters;
35MM standard guide rail installation;
Supports 3-channel analog transmission output.
| Application |
Power combination transmitter is a device that isolates and transmits electrical parameters such as current, voltage, frequency, power, and power factor in the power grid into linear DC analog or digital signals. This product can be widely used in energy management systems, substation automation, distribution network automation, residential power monitoring, industrial automation, intelligent buildings, negative control systems, switchgear, and other scenarios.
| TECHNICAL INDEX |
| Communication input | electric current1A,5Aclass |
| Input load | current transformerCT:≤0.2VA |
| Communication input | AC100V、220Vperhaps400V(Please specify when placing an order) |
| Input load | voltage transformerPT:≤0.2VA |
|
input overload |
1.2Twice sustained |
| overload capacity | Acceptable 1.2 Multiple rated values (continuous),2 Double rated value(12s) |
| accuracy | 0.5% |
| response time | <400ms |
| Output voltage | 0~10Vdc,0~5Vdc(Load resistance=input voltage/10mAdc) |
| output current | 0~20mAdc,4~20mAdc(Load resistance=10Vdc/Output current) |
| Working environment temperature and humidity | 0~50℃/less than80%Relative humidity (non condensing state) |
| Storage environment temperature and humidity | -20~70℃/less than70%Relative humidity (non condensing state) |
| Use power supply | AC86~265V/DC110~300V |
| quarantine | input/output/power supply/casing |
| Power consumption | power waste:≤5VA |
| Housing material | ABSFireproof materials |
| weight | make an appointment 500 can |
| compressive strength | input/power supply>2kV, input/output>2kV, output/power supply>2kV |
| Insulation impedance | Input, output, and power supply to the chassis>5MΩ |
| External dimensions | 120(L)×110(W)×75(H)mm |
| Installation method | 35mmInstallation of standard guide rails and base screws |
| Selection instructions |

| Outline dimension diagram |

| Wiring Terminal Diagram |
Signal input:
Transmission input:
Working power supply: