- Phone
-
Address
No. 17, Suodi Village, Zhangjiawan Town, Tongzhou District, Beijing
Beijing Penglichi Technology Co., Ltd
No. 17, Suodi Village, Zhangjiawan Town, Tongzhou District, Beijing
GB25203-2010 Fire Supervision Technical Equipment with Level 4 ConfigurationThe instrument box is a portable fire detection instrument box launched by Beijing Penglichi Technology Co., Ltd. It is developed based on the "GB25203-2010 Fire Supervision Technical Equipment Configuration", "GB25201-2010 Maintenance and Management of Building Fire Protection Facilities", and "GA503-2004 Technical Regulations for Building Fire Protection Facility Testing"The complete set of building fire protection facility testing boxes consists of two types of testing boxes: conventional testing equipment boxes and professional testing equipment boxes. It gathers commonly used fire detection instruments and tools for fire detection and maintenance, including automatic alarm and control systems, fire hydrants, automatic sprinkler systems, smoke and exhaust systems, emergency lighting systems, fire electrical systems, and fire-resistant and flame-retardant materials.
The equipment configuration of the building fire protection facility testing box is complete, the design and selection are reasonable, and it can be calibrated by national legal measurement and testing units, which meets relevant standards. The VC12 building fire protection equipment testing box is easy to operate and master, suitable for on-site use. It is suitable for building fire protection equipment testing, building fire protection equipment maintenance and testing, fire engineering testing and debugging, fire supervision engineering acceptance, fire industry professional skill appraisal and training, property insurance evaluation, user self inspection, and engineering supervision. It realizes the evaluation of whether the fixed fire extinguishing system can truly function under fire conditions based on technical data.
GB25203-2010 Fire Supervision Technical Equipment with Level 4 ConfigurationThe instrument box is a portable fire detection instrument box launched by Beijing Penglichi Technology Co., Ltd. It is developed based on the "GB25203-2010 Fire Supervision Technical Equipment Configuration", "GB25201-2010 Maintenance and Management of Building Fire Protection Facilities", and "GA503-2004 Technical Regulations for Building Fire Protection Facility Testing"
(Optional configuration according to usage requirements. This testing box may change without prior notice due to technological updates.)
Beijing Penglichi Technology Co., Ltd. specializes in the research, development, and production of fire protection technology equipment, with strong professional technical strength. The developed fire supervision technology equipment has complete specifications and varieties, reliable quality, simple and convenient use, and reasonable prices, which are highly welcomed by fire supervision departments and fire detection companies.
Level 4configuration
serial number |
product name |
parameter |
quantity |
1 |
Digital Illuminance Meter |
Measurement range not less than 2000lx, accuracy: ± 5%, with data retention and reading locking functions |
1 |
1 |
Digital sound level meter |
Measurement range: 30db-130db, accuracy: ± 1.5db, sampling rate: 2 times/s |
1 |
2 |
Laser rangefinder |
Measurement range not less than 60 meters, accuracy not greater than 3mm |
1 |
3 |
Digital anemometer |
Range: 0m/s-45m/s, accuracy: ± 3%, with LCD backlight and data retention function |
1 |
4 |
Digital micropressure gauge |
Measurement range: 0pa-3000pa, accuracy: ± 3%, with reset function, equipped with detection hose. |
1 |
5 |
Fire hydrant pressure measuring joint |
Dynamic and static pressure measurement, pressure gauge measurement range 0MP-1.6Mpa, accuracy: 1.6 level, surface diameter 60mm, inlet 65mm, outlet 19mm |
1 |
6 |
Point type temperature detector function tester |
The height of the detection pole shall not be less than 2.5 meters, with a built-in power cord and a continuous time of not less than 2 hours |
1 |
7 |
Point type smoke detector function tester |
The height of the detection pole shall not be less than 2.5 meters, equipped with a smoke hood and built-in power cord, with a continuous time of not less than 2 hours |
1 |
8 |
Linear beam smoke detector filter |
The dimming values are 0.9db and 10.0db, with one piece each |
1 |
9 |
Flame detector function tester |
Infrared wavelength ≥ 850nm, ultraviolet wavelength ≤ 280nm. The height of the detection rod shall not be less than 2.5m. |
1 |
10 |
Grounding resistance measuring instrument |
Digital, measurement range: 0 Ω -1000 Ω, accuracy ± 2% |
1 |
11 |
Insulation resistance measuring instrument |
Measurement range: 1 Ω -2000 Ω, accuracy ± 4% |
1 |
12 |
Digital Multimeter |
Can measure AC/DC voltage, DC current, resistance, capacitance |
1 |
13 |
clamp meter |
Measurement range 0A-200A |
1 |
14 |
Foam weighing electronic scale |
Measurement range not less than 30kg |
1 |
15 |
Verticality tester |
Vertical line not less than 6m, can be used on materials such as metal, concrete, wood, etc |
1 |
16 |
Digital temperature and humidity meter |
Environmental temperature and humidity detection |
1 |
17 |
Multi functional slope measuring instrument |
Measurable levelness and slope |
1 |
18 |
Leakage current detector |
Measurement range: 0A-2A |
1 |
19 |
Infrared Thermometer |
Measurement range: -30 ℃ -+800 ℃, accuracy: ± 2% |
1 |
20 |
Portable combustible gas detector |
It can detect the concentration of combustible gases such as carbon monoxide, hydrogen, ammonia, liquefied petroleum gas, and methane, and issue sound and light alarms. It also has explosion-proof function. |
1 |
21 |
Flammable liquid detector |
Rechargeable, capable of measuring the evaporation concentration of gasoline, kerosene, diesel and various organic solvents, sensitivity: 50 × 10-6, detection range: 0 × 10-6-19990 × 10-6, LCD display, sound and light alarm |
1 |
22 |
Combustible gas detection tube |
Can detect flammable liquid vapors such as gasoline, kerosene, diesel, etc., with two detection concentrations, and equipped with a sampler |
1 |
23 |
Spring type carbonization depth measuring instrument |
Metal handheld, spring linked, precision 1mm |
1 |
24 |
Rebound hammer |
Standard kinetic energy: 0.735J |
1 |
25 |
digital thermometer |
Measurement range: 0 ℃ -750 ℃, accuracy: ± 1%, equipped with rod and surface probes |
1 |
26 |
telescope |
The magnification is not less than 7 × 35 |
1 |
27 |
On site inspection light |
Long range not less than 500 meters, high continuous working time not less than 3 hours |
1 |
28 |
iodine tungsten lamp |
Handheld, fixed bracket, and connecting cable, with a power of over 1000W |
1 |
29 |
Remanence meter |
Range: 0mT-100 mT, Resolution: 0.1mT, LCD Display |
1 |
30 |
Line tracer |
Equipped with LCD display and sound and light alarm function |
1 |
31 |
electrostatic voltmeter |
Measurement range: 0kV-40 kV; Accuracy ± 20V |
1 |
32 |
Stereomicroscope |
Inverted binocular, eyepiece 10 * 20mm, objective 1 * 58mm |
1 |
33 |
portable hard drive |
Storage capacity not less than 320GB |
1 |
34 |
voice recorder |
The recording time shall not be less than 70 hours |
1 |
35 |
digital camera |
Pixel size not less than 8 million, with wide-angle and |
1 |
36 |
Digital Camera |
Hard disk type |
1 |
37 |
Fire supervision equipment box |
Made of aluminum alloy material, it has the characteristics of portability, drag function, and lightweight and wear-resistant material; The position and size of equipment and materials placed inside the box should be scientifically reasonable and able to be fixed; The box should be equipped with storage locations for relevant documents and equipment accessories. |
3 |