- Phone
-
Address
805, South Building, Fude Building, 1688 Sichuan North Road, Hongkou District, Shanghai
Shanghai Botong Scientific Instrument Co., Ltd
805, South Building, Fude Building, 1688 Sichuan North Road, Hongkou District, Shanghai
G4070 Conducted Immunity TestRelated introductions:
Special testing of NSG4070, an improved version of NSG2070- a multifunctional EMC immunity testing system.
The NSG4070 has a wide frequency range (from 9kHz to 1GHz) and a modular structure that uses external or internal amplifiers, making it widely applicable
This includes testing conducted in accordance with IEC 61000-4-6, various high current injection applications, signal generators and power meters used as testing systems in IEC 61000-4-3, IEC 61000-4-20, and IEC 61000-4-21 applications.
Due to its user-friendly firmware, the NSG4070 can operate independently without the need for an external computer or control software. Of course, it can also be remotely controlled for system operations.
Insert the USB memory into the panel to transfer and save test and measurement data to generate test reports.
Built in power amplifier module suitable for various applications.
Multiple EUT detection functions.
5.7 "TFT color display.
Built in menu control software.
Including remote control software and the ability to automatically generate test reports.
G4070 Conducted Immunity TestTechnical Indicators:
Signal generator RF frequency range: 9kHz – 1GHz
Resolution:
1Hz reference frequency: reference frequency output: 10MHz RF level, level range: -60dBm -+10dBm
Resolution: 0.1dB
Set time: 10ms
Modulation frequency range: 1Hz-50kHz, frequency resolution: 1Hz, pulse modulation rise/fall time (10%/90%):<1 μ s
Modulation frequency range: 1Hz-50kHz, frequency resolution: 1Hz
Duty cycle: 10% -90%, external modulation delay time:<1 μ s/180 °
Cycle: 20 μ s less, pulse width: 10 μ s less
Power meter frequency range: 9kHz – 1GHz, linear measurement range channel 1: -15dBm –+27dBm, channel 2, 3-25dBm –+20dBm
Large input/lossless channel 1-3:+28dBm
Bottom noise: greater than 6dB below the measurement range
Input return loss:>20dB (below 500MHz),>17dB (500MHz-1GHz)
Connector: BNC socket, 50 Ω
Accuracy: 150KHz – 1GHz, 10-30 ° C
Normal output power: 20W, 30W, 75W
Frequency range: 150kHz – 230MHz, 150kHz – 230MHz, 150kHz – 230MHz
Input return loss: small 10dB, small 10dB, small 10dB
This software allows the use of the test report generator and all data processing functions without a remote control connection to NSG 4070
Remote control: Control NSG 4070 remotely via LAN, USB, or RS232
Data transfer: Transfer between NSG 4070 and computer via LAN connection or using USB stick
Display: Power meter display with reference value settings (in dBm, V, dB μ V), small/large display, and input of log files (frequency, time, power)