Phone
15830190109
-
Address
2F, Building 5, Zone C, Fangyi Science Park, No. 313, the Pearl River Avenue, Shijiazhuang High tech Zone, Hebei Province, China
Hebei Emery Technology Co., Ltd
15830190109
2F, Building 5, Zone C, Fangyi Science Park, No. 313, the Pearl River Avenue, Shijiazhuang High tech Zone, Hebei Province, China
1 project introduction
The furnace flue gas analyzer is a device that continuously monitors the concentration and total emissions of gaseous pollutants emitted by atmospheric pollution sources and transmits the information in real time to the competent department. It is calledSmoke Automatic Monitoring System "(abbreviated asCEMS)The concentration of gaseous pollutants in the exhaust gas emitted from fixed pollution sources such as boilers, industrial furnaces, incinerators, etc(mg/m3)And emission rate(kg/h、t/d、t/a)Conduct continuous and real-time tracking testing.
According to the monitoring requirements provided by your company, our independently developed furnace flue gas analyzer adopts advanced technologyConstant potential electrolysis method+Extraction condensation methodExtraction based hot wet methodCEMSCapable of measuringSO2、NOx、O2Multiple parameters such as temperature, pressure, flow rate, humidity, etc., and transmit all monitoring parameters to the userDCSThe system communicates with the data system of the environmental protection department through a data acquisition instrument. The system equipment is placed in the analysis cabin for easy operation and maintenance; The entire system has a simple structure, modular design, strong stability, and low operating costs.
2 Introduction to System Components
CEMSGenerally, it consists of a smoke monitoring subsystem (dust) and a gaseous pollutant monitoring subsystem(SO2、NOX)Smoke parameter monitoring subsystem(Temperature, pressure, flow rateO2)The system consists of four basic components: system control and data acquisition and processing subsystem. The specific introduction is as follows:
picture2-2-1 removableCondensation methodCEMSSystem composition diagram
stem or root of plantsThe system consists of a sampling probe placed on the chimney, a dust analyzer, and a temperature pressure flow integrated probe, as well as an analysis cabinet placed in the cabin、Composed of standard gas and compressed gas sources.
picture2-3-1 removablecondensationlawCEMSFront of system cabinetone
|
number |
name |
describe |
|
(1) |
control panel |
includePLCControl interface, smoke blowback, flow rate blowback, leak detection/Maintain three control buttons, sample gas flow meter, and calibration gas inlet |
|
(2) |
IPC |
Install data collection, conversion, display, storage, and upload software |
|
(3) |
UV gas analyzer |
measureSO2、NOx、O2class |
picture2-3-2 removablecondensationlawCEMSSystem cabinetstraightfacetwo
|
number |
name |
describe |
|
|
(1) |
Solid state relay |
Control the heating of the heat tracing tube and sampling probe |
|
|
(2) |
relaygroup |
achieveanswerelectric actuatorAnd the various states of the systemControl, etc |
|
|
(3) |
PLC |
General control unit |
|
|
(4) |
switch power supply |
Provide the interior of the cabinet24VDCpower supply |
|
|
(5) |
filter regulators |
Provide stable and dry high-pressure air for the system |
|
|
(6) |
filter |
Remove water and impurities from the sample gas |
|
|
(7) |
Compressor type condensing dryer |
Quickly condense water from high-temperature humid and hot gases into liquid form in a heat exchanger, and discharge the condensed water through a peristaltic pump (or other means) to achieve gas-liquid separation |
|
|
(8) |
Humidity alarm |
When the condenser malfunctions, prevent condensed water from entering the analyzer |
|
3 Project Design Proposals
SO2、NOX、O2、 Temperature, pressure, flow rate (flow rate), dust;
Brick and tile kiln flue gas onlineThe system mainly has the following features:Technical advantages:
|
Serial Number |
project |
Model and specifications |
quantity |
factoryfamily |
notes |
|
1 |
Gaseous pollutant monitoring subsystem |
||||
|
1.1 |
Gaseous pollutant analyzer |
EM-5 NOX/SO2/O2 |
1tower |
Hebei Emery |
|
|
1.2 |
Preprocessing cabinet |
Material: Carbon Steel Spray Coating Internally integrated sample condensation processing unit, control unit, blowback unit, and humidity module; |
1cover |
Hebei Emery |
|
|
1.3 |
Sampling probe |
Electric heating sampling probe |
1cover |
Hebei Emery |
|
|
1.4 |
sampling line |
Electric heating sampling pipeline |
30m |
domestic |
standard configuration30m |
|
2 |
Smoke parameter monitoring subsystem |
||||
|
2.1 |
Temperature pressure flow integrated machine |
PT-500Temperature, pressure, flow rate |
1cover |
Hebei Emery |
|
|
3 |
Smoke and dust monitoring subsystem |
||||
|
3.1 |
Dust analyzer |
DMS-5smoke and dust |
1cover |
Hebei Emery |
|
|
4 |
System control and data acquisition subsystem |
||||
|
4.1 |
IPC |
Integrated industrial computer |
1tower |
domestic |
|
|
4.2 |
Industrial computer software |
Operating systems, databases, and application software; |
1cover |
Hebei Emery |
|
|
4.3 |
Data acquisition instrument |
Data acquisition instrument (including software) |
1tower |
domestic |
Local procurement by Party A |
|
5 |
calibration system |
||||
|
5.1 |
pressure reducing valve |
copper |
1cover |
domestic |
|
|
5.2 |
Standard gas |
steel cylinder8L |
1cover |
domestic |
|
|
6 |
other |
||||
|
6.1 |
Engineering installation consumables |
Internal cables, pipe valves, etc. of the system |
1cover |
domestic |
|
|
6.2 |
information |
Including user manual, cabinet wiring diagram, testing report, etc |
1cover |
Hebei Emery |
|
|
6.3 |
spare parts |
|
1cover |
domestic |
|
|
Serial Number |
name |
Specification and model |
unit |
quantity |
notes |
|
1. |
Signal conversion module |
232change485module |
piece |
1 |
|
|
2. |
Quick plug connector |
Φ6,Φ8 |
cover |
1 |
|
|
3. |
Ceramic filter cartridge |
Φ39*Φ21*100 |
individual |
1 |
|
|
4. |
temperature sensor |
PT100 |
individual |
1 |
|
|
5. |
Fluorine tube |
Φ6 |
cover |
1 |
|
|
6. |
Fluorine tube |
Φ8 |
cover |
1 |
|
|
7. |
Screw spare parts |
Specification |
wrap |
1 |
|
|
Serial Number |
name |
Specification and model |
unit |
quantity |
notes |
|
1. |
Ceramic filter cartridge |
Φ39*Φ21*100 |
individual |
1 |
|
|
2. |
temperature sensor |
PT100 |
individual |
1 |
|
|
3. |
Graphite gasket |
Φ80*Φ50*3 |
individual |
1 |
|
|
4. |
Graphite gasket |
Φ39*Φ21*2 |
individual |
1 |
|
|
5. |
temperature controller |
TC4S-24R |
individual |
1 |
|
|
6. |
Ferrulestraight throughjoint |
Φ8-Φ8 |
individual |
1 |
|
|
7. |
Ferrulestraight throughjoint |
Φ6-Φ6 |
individual |
1 |
|
|
Serial Number |
name |
quantity |
|
1. |
Manual for Temperature Pressure Flow Integrated Machine |
1share/cover |
|
2. |
Dust analyzer manual
|
1share/cover |
|
3. |
system specification |
1share/cover |
|
4. |
System testing report |
1share/coverFurnace flue gas analyzer Furnace flue gas analyzer Furnace flue gas analyzer |