- Phone
-
Address
30th Floor, Science and Technology Capital West Building, Beijing East Road, Shanghai
Shanghai Chengli Electronic Technology Co., Ltd
30th Floor, Science and Technology Capital West Building, Beijing East Road, Shanghai
1. United StatesKIC2000Furnace Temperature TesterKIC 9Channel furnace temperatureKICFurnace Temperature TesterKICthermometer
Furnace Temperature TesterKIC2000
(1)Less sources of error, high reliability,
(2)Guided operation software, simple and easy to learn
(3)Measurable peak and reflow soldering temperature
(4)There is a predictive function curve, which is convenient for technicians to operate
(5)Has intelligent start stop function
(6)number of channels9
Specifications:
Measuring range:-50~+1050degree
essence indeed Degree:0.1~0.3degree
Repetitive accuracy:±1.5degree
Standard purchase items: 1 Taiwan
Temperature measuring instrument host 1 Taiwan
Thermal insulation shell of thermometer 1 Taiwan
suitcase 1 Taiwan
temperature measuring wire 9 strip
Data CD 1 Zhang
instruction manual 1 this
data cable 1 strip
Factory inspection report 1
United StatesKIC 2000Furnace Temperature Tester
detailed explanation:
1.Traditional temperature curve measurement and setting have always been time-consuming tasks, andKICofSlimKIC 2000Type temperature/The time process setter solves this traditional problem.
2.The operator can select the solder paste to be used from the pre-set solder paste characteristic database.SlimKIC 2000Automatically set the required process frame or window.
3.If cooperatingNavigatorTMAfter one test, the software automatically and accurately estimates the cost, allowing qualified operators to select the solder paste from the pre-set solder paste characteristic database.SlimKIC 2000Automatically set the required process frame or window. Reduced the need for repeated experiments. The demand for experimentation.
4.SlimKIC 2000providePrizesIndicators to assist in understanding and setting up process capabilities for operational processes. The operational process can determine whether further fine-tuning and optimization are necessary.
5.If cooperatingNavigatorTMThe software can automatically select the set point from all possible combinations of parameter settings, without the need for manual judgment and experimentation for continuous optimization.
6.If cooperatingAutoFocusTMThe software can calculate the initial process parameters for you from past setup experience. No need to guess for yourself. The software also has automatic learning function, which can be completed in one go with sufficient experiencePrizesset up.
7.If cooperatingKIC PilotTMFor some furnaces, the parameter settings of the furnace can be automatically adjusted without the need for manual adjustment.
8.In complex or large quantitiesBGAand so onPCBAUp, traditional5Channel time measurement-The thermostat can no longer meet the technical requirements.
9.KIC SlimKIC2000provide6,9to12通道。KIC Startprovide6Channel. Wave soldering and reflow soldering are universal.
10.In terms of software, the simulation curve function, five group curve comparison function, and temperature measurement accuracy are unparalleled among other similar brands; In terms of hardware, it eliminates the tedious process of separating the temperature measuring instrument host and insulation box for two adjustments during temperature measurement. The host is directly placed in the insulation box of the insulation material, and can be directly connected to the computer interface for measurement and reading without taking it out.
KIC SlimKICTMProviding you with high accuracy and automation!
1.High performing softwareKIC NavigatorTMisSlimKIC2000The choice. This software automatically analyzes tens of millions of temperature and chain speed combinations, and in a very short period of time(Within one minute)Provide user optimized settings.
2.Quick and easy to use
Users only need to tellKIC NavigatorTMHis process requirements will be conveyed to him by the software for setting points. Its high degree of automation capability enables operators who are not familiar with the process to use it. Users no longer need to try the furnace multiple times to obtain positive optimized settings.
3.More accurate and optimized process settings
Due to time resource limitations, the manually set increase or decrease range is generally not too small(About in5ºC左右).KIC NavigatorTMBut able to1ºCMake small adjustments to make the process settings more accurate and optimized.
By automatically handling complex process settings,SlimKIC® 2000™Creating curves is so easy that any operator can quickly optimize the process. Simply select the required information from the files that have collected hundreds of commonly used solder paste specifications, and the software will automatically define the process window. The temperature zone of the furnace and the planning of thermocouples on the product will automatically use this innovative technology.
SlimKIC 2000Simplified curve measurement by summarizing the process into a single data point— Process Window Index? (PWI)This way, you can truly understand how good your curve is. The simplified user interface guides operators throughout the entire curve measurement process, reducing potential incorrect furnace settings and minimizing error rates.
Technical specifications:
precision:±1.2Cresolution:0.3C-0.1CInternal operating temperature: 0C-105C
Thermocouple compatibility:Type K, 9 or 12 channelstemperature range: -150C-1050C
Thermal receiver:433.92 MHz (Dual Unit Model only)Power requirements:standard9VAlkaline battery
Data storage mode:After completing the curve measurement, the data is downloaded to the computer through a download cable.
Dual transmission mode:The data is transmitted in real-time to the computer during the measurement process. It is also stored inside the instrument for high-speed download after measurement is completed
KIC 2000Furnace Temperature TesterProduct Introduction
![]()

![]()

KIC 2000 Product Introduction
Type: KIC2000 from the United StatesFurnace Temperature Tester
Customized processing: Yes
Brand: KIC, USA
Model: KIC 2000
Measurement range: -150-1050 (℃)
Temperature measurement resolution: 0.1 ℃
Instrument dimensions: 260 * 80 * 20 (mm)
Insulation box size: 330.2 * 93 *. 34 (mm) - furnace size
Packing quantity: 1
Product Features:
1. Import automatic thermocouple position settings.
2. Automated evaluation of temperature curves.
3. Automatic visualization operation instructions.
4. When the instrument overheats or the battery level is too low, it will automatically give
Give instructions to stop temperature curve testing.
5. Automatic retrieval can ensure the integrity of temperature curve data.
6. Automatic confirmation of production process stability.
Product specifications:
Accuracy:+/-1.2 ℃
Resolution: 0.3 ℃ to 0.1 ℃
Internal operating temperature: 0 ℃~105 ℃
Applicable thermocouples: 9/12 K-type thermocouples
Temperature measurement range: -150 ℃ to 1050 ℃
System compatibility: PC compatible
Power requirement: 9-volt alkaline battery
Size (equipped with standard insulation cover): length 330 * width 95 * height 34.5 (mm)

Precautions
1. First, check if the battery is fully charged, and the surface temperature should not exceed 40 ℃. To test accuracy, please try to use the instrument as much as possible
Start testing when the surface temperature is below 40 ℃.
2. Confirmation of communication between PC and instrument: The instrument thermocouple must detect and collect constant temperature before proceeding to the next step of testing,
3. The insulation box can withstand a maximum temperature of 280 ℃ for 9 minutes. Please exceed this range and ensure that the internal temperature of the instrument does not exceed 85 ℃.
4. If not in use for a long time, please turn off the power and remove the battery. If needed, please try to store the battery and use it in an environment below 60 ℃
As soon as the power is turned on, there will be a continuous noise when the battery is running for a long time. Please check if the battery is low and replace it. The normal sound is about every 5 seconds,
Make a few sounds.
5. When passing through the furnace, please make sure to cover the insulation box with a "click" sound and seal the yellow insulation cotton.
6. Only one can be taken at a timeFurnace Temperature TesterThe recorder is connected to the computer. Multiple recorders cannot be connected to the computer simultaneously
Choose one of the same USB ports.
7. After passing through the furnace again, wait for the insulation box to cool down before using it again