- Phone
-
Address
Zone 1, Times Headquarters Base, Tianqiao District, Jinan City
Shandong Derrick Instrument Co., Ltd
Zone 1, Times Headquarters Base, Tianqiao District, Jinan City
DRK-Q90Fully automatic true density testerThe equipment adopts an integrated containerized metal pipeline and is a fully automatic testing instrument that uses gas displacement method to detect the true density of liquids (non-volatile, non corrosive) and solid substances. The instrument is mainly used in industries such as food safety, new energy, polyurethane, insulation materials, environmental protection, and minerals, and can test substances such as food, beverages, petroleum, coal, floating beads, alumina, refractory materials, battery materials, etc.

Working Principle:
DRK-Q90Fully automatic true density testerThe equipment adopts an integrated containerized metal pipeline and is a fully automatic testing instrument that uses gas displacement method to detect the true density of liquids (non-volatile, non corrosive) and solid substances. The instrument is mainly used in industries such as food safety, new energy, polyurethane, insulation materials, environmental protection, and minerals, and can test substances such as food, beverages, petroleum, coal, floating beads, alumina, refractory materials, battery materials, etc.
Working Principle:
Using Archimedes' principle - gas expansion displacement method, small molecule inert gas (He or N2) is used as the medium, and the ideal gas state equation: PV=nRT is used to calculate the volume of gas displaced by the sample in the test chamber, so as to accurately measure the skeleton volume of the sample (including closed pores), and then calculate the true density value based on the density equation: ρ=M/V.
The gas expansion displacement method replaces liquid with gas to measure the volume of the sample displaced. This method can avoid testing errors caused by sample dissolution in immersion methods and has the advantage of not damaging the sample. Because gas can penetrate the extremely small pores and irregular pores on the surface of the sample, the measured sample volume is closer to the true volume of the sample, which can be used to calculate the density of the sample, and the test value is also closer to the true density of the sample.
Product Parameters:
1. Main functions:
(1) True density (various non-volatile, non corrosive solids, liquids, including closed pores);
(2) Real volume (various non-volatile, non corrosive solids and liquids, including closed pores);
(3) Visual density (using liquid paraffin to test the visual density of various samples);
(4) Visual volume (using liquid paraffin to test the visual volume of various samples);
(5) Porosity (the porosity of a material can be calculated by its true density and apparent density)
(6) Open close porosity (for block materials such as foam materials, rock cores, metal components, etc.), in accordance with GB/T 10799-2008,ASTM D6226-2005,ISO4590-2002; (A computer must be configured)
2. Test accuracy: accuracy difference ≤ ± 0.02%, repeatability difference ≤ 0.02%, division value: 0.0001g/cm3; (Based on the test results of the standard sample)
3. Pressure range: 0KPa-100KPa. Users can set pressure values as needed to reduce measurement errors caused by sample deformation due to excessive pressure;
4. Pressure accuracy: High precision imported silicon thin film capacitive pressure sensor, with an accuracy of 0.1% of the actual reading, better than 0.1% of the full range;
5. Testing speed: Complete the entire testing process in 2-5 minutes;
6. Test range: the true density density of the sample to be tested is unlimited, and it can test all kinds of nonvolatile and non corrosive liquids and all kinds of powder, granular, massive and foam solids;
7. Sample tube: standard 10cm3 stainless steel true density sample tube; Special sample tubes with a capacity of 5cm3-1000cm3 can also be customized as needed;
8. Test gas: 40 liters of pure helium gas with a purity of ≥ 99.999%; Other gases such as nitrogen are optional;
9. Dual gas selection: Users can choose instruments with dual gas function according to their needs, with high-purity helium as the test gas and high-purity nitrogen as the driving gas, resulting in lower long-term usage costs;
10. Core accessories: Yuanzhuang imported valves and silicon thin film pressure sensors;
11. Data processing: Dual control system, can be connected to a computer for use, can also be used independently, and users can switch freely according to their needs;
12. Instrument dimensions: length -350mm; width -350mm, height -460mm; net weight -22kg;
Product Features:
1. Dual control system, which can be connected to a computer through a serial port and operated through computer software; The instrument itself is equipped with a microcomputer touch screen control system, and the instrument can also be operated through the touch screen. Both operation modes are fully automated, without the need for manual supervision, and automatically generate and save test results. The dual control system can provide users with more convenient operation methods. Users can switch operation modes at any time according to their needs, and both systems have full voice prompts throughout the process;
2. The sample tube can be directly used as a testing chamber, which can effectively utilize the volume of the testing chamber and significantly improve the testing accuracy. Sample tubes of different volumes can simultaneously meet the needs of micro volume and large volume sample loading, in order to achieve the goal of improving testing accuracy;
3. Sample tube automatic installation, some sample tube automatic installation devices only require placing the sample tube in the designated position, and the instrument automatically installs the sample tube to the connection port, making the operation more convenient and avoiding testing errors caused by manual installation of the sample tube.
4. Yuan installed imported pneumatic valve with no heating problem, eliminating the impact of electromagnetic valve heating on testing accuracy;
5. Integrated modular pipeline with no pipeline joints between valves, reducing air leakage points and ensuring uniform temperature distribution;
6. Automatic sealing inspection of the gas path system, automatic judgment of whether there is air leakage in the reference chamber and sample tube, ensuring the accuracy of the test results;
7. Through the control unit of the operation interface, the actions of various hardware components of the instrument can be controlled, which helps operators understand the working principle of the instrument and timely discover the fault point when the instrument malfunctions, facilitating subsequent inspection and maintenance.
8. After the test is completed, the system automatically returns to normal pressure to prevent sample splashing when disassembling the sample tube;
Configuration List:
Serial number, component name quantity
1 Open and closed cell rate tester 1 unit
2 USB flash drive (8GB) 1 piece
3 reference material 1 piece
4 10cm3 true density sample tube 2 pieces
5 Sample tube joint sealing ring 18 * 2.4 2 of them
6 PU gas pipeline 10 meters
7 Serial port cable (1.5m) 1 piece
8 power cord 1 piece
9 1A insurance tube 2 of them
10 Sample tube brush 2 pieces
11 Stainless steel sample spoon 1 set
12 Insulated wire gloves 1 pair
13 Dust Blower 1 piece
14 Tool kit (wrench, screwdriver) 1 set
15 Helium pressure reducing valve (including pressure gauge) 1 piece
16 High purity helium gas, including steel cylinder, 12MPa, 40 liters, purity 99.999% 1 bottle
Optional accessories: * 1 computer 1 unit