Fully automatic thermal analyzer

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The TD-1 fully automatic thermal analyzer adopts microcomputer controlled independent temperature control, program design calibration program, analysis program, and stores 4 sets of methods for easy connection to any brand of chromatograph. Industry field: Indoor Environmental Testing (TVOC) and Detection of Volatile Toxic Gases in Soil

Product Details

Introduction to TD-1 Fully Automatic Thermal Analyzer

main features:

  1. Strong universality
  2. Can be used in conjunction with various models of domestic and imported gas chromatographs
  3. Fast heating and small gradient, both the thermal decomposition furnace and the activation furnace can operate simultaneously
  4. It also has the function of cleaning the sample adsorption tube, avoiding cross contamination
  5. The scientific design of sealing, including the installation and sealing of sample tubes, is simple, reliable, and easy to operate
  6. Unique sample output tube heating design to prevent sample condensation
  7. The injection and data processing run synchronously. When in use, simply set the analysis time, injection time, and purge time It runs dynamically and can trigger external data processing devices to synchronize its operation, greatly reducing timing errors
  8. Memory storage4Analysis parameters
instrumentParameters:
  1. Analysis furnace temperature range: room temperature~400℃increment1 Temperature control accuracy:±0.1℃
  2. Sample transmission pipeline range: room temperature~220℃increment1 Temperature control accuracy:±0.1℃
  3. Injection valve temperature range: room temperature~200℃increment1 Temperature control accuracy:±0.1℃
  4. Activation temperature range: room temperature~400℃increment1 Temperature control accuracy:±0.1℃
  5. Activation quantity: Can be activated simultaneously7Root analysis tube (requires addition of activation unit attachment)
  6. Analyze pressureinternet trafficAnd calibrated flow rate:0~300ml/min,Continuing Adjust
  7. Analysis time, injection time, activation time0~99Minutes can be freely set according to the needs of the analyzed sample
  8. Analysis of recovery rate: achievable under selected sample components and corresponding operating conditions95%the above
  9. Linear: generally achievable under selected sample components and corresponding operating conditions0.999
  10. Analysis tube specification: suitable for outer diameterφ6(1/4inchVarious standard adsorption tubes. The material can be stainless steel tube, quartz glass tube, hard glass tube, etc

Update time: August 10, 2020 17:18:22