serial number |
project |
Instrument technical specifications |
1 |
Applicable method |
Chlorine:GB/T 18612、SH/T1757、NB/SH/T6056、GB 23971、YB/T5022、ASTM D5808、ASTM D4929... Sulfur:GB/T11061、GB/T11141、GB/T3208、SH/T 0253、SH/T 0222、SH/T1147、SH/T 1797、SY/T7508、HG/T 5613、ASTM D3120、ASTM D3246... |
2 |
analyze samples |
Used for the determination of total sulfur or total chlorine content in products such as oil, petrochemicals, aromatic hydrocarbons, and natural gas |
3 |
injection volume |
Liquid:1~50ul Gas:5~10ml |
4 |
measurement range |
S:light oil:0.05mg/L~10000mg/L~percentage content Cl:light oil:0.1mg/L~10000mg/L~percentage content |
5 |
detection limit |
S: 0.05mg/L; Cl:0.1mg/L |
6 |
Temperature control range and accuracy |
0℃~1200℃,±1℃ |
7 |
Repeatability (error) |
0.05mg/L ≤ sample (or standard sample) concentration <0.5mg/L,±0.1mg/L 0.5mg/L ≤ sample (or standard) concentration < 1.0 mg/L, RSD ≤ 10% 1.0mg/L ≤ sample (or standard) concentration ≤ 10 mg/L, RSD ≤ 6% Sample (or standard) concentration>10 mg/L,RSD ≤4% |
8 |
Maximum electrolysis current |
±2mA |
9 |
Amplifier electrolysis voltage |
±30V |
10 |
input impedance |
greater than106Ω |
11 |
Baseline noise |
gainK=2400, When the sampling resistance R is 10K Ω, the baseline noise is not greater than 2UV |
12 |
baseline drift |
not greater than5mv/min |
13 |
Gain range |
0~2560 |
14 |
Bias voltage range |
0~500mV, Continuously adjustable |
15 |
Air source requirements |
Purity of argon gas99.999%Output pressure ≤ 0.2MPa Oxygen purity99.999%Output pressure ≤ 0.2MPa |
16 |
analysis time |
2min |
17 |
Data communication interface |
RS232, Can transfer data between LIMIS systems |
18 |
Weight,kg |
60 |
19 |
sizemm |
Instrument host: LongX Width x Height: 600 x 500 x 520 (mm) Automatic sampler: longX Width x Height: 360 x 340 x 460 (mm) |
serial number |
project |
Performance Characteristics |
1 |
key component |
chlorineThe electrolytic cell adopts silver rod electrodes and a large capacity design, without the need to supplement electrolyte during the experiment, and has a longer stable use time than ordinary electrolytic cells. Accurate measurement, reduced maintenance frequency, and improved work efficiency. |
2 |
Blind sleeve typequartz tube |
Blind quartz tube, throughround tripThe combustion method ensures the combustion of the sample,Without using tungsten trioxide as a catalyst, the sample can still be converted and carbon deposition can be avoided. |
3 |
Gas flow control |
Using a mass flow meter and computer-controlled gas flow rate, the gas flow rate is stable, accurate, and without fluctuations. The instrument has better repeatability and higher measurement accuracy for small content samples. At the same time, the mass flow meter detects abnormal flow of carrier gas or auxiliary gas, and the workstation suspends the injection of oil samples to prevent carbon deposition and pollution of the gas path and electrolytic cell due to sample oxygen deficiency cracking. |
4 |
Gas stabilization system |
Sample cracking stabilizing device The installation of a pressure stabilization system in the gas circuit avoids interference from gas flow and pressure fluctuations on the measurement. |
5 |
Temperature control system |
Automatic control device for cracking furnace fan, automatic on/off of cooling fan, no need for personnel to wait for shutdown. It has the function of warning errors during operation and prohibiting sample injection due to errors, and has the function of automatic power-off protection against overheating. Mixing sectionairtightnessOkay, okay,Equipped with a constant temperature system30 ℃, to prevent a decrease in electrolyte activity caused by low temperature |
6 |
drying system |
adoptMembrane dryerDehydration without frequent replacement, stable performance. |
7 |
cracking furnace |
Using imported electric furnace wire to improve the service life of the cracking furnace. |
injection system | ||
1 |
Fully automatic sampling system |
adopt19 positionsor156bitFully automatic sample injection system,Computer control,Direct injection,The experimental process is fully automated, with automatic sample replacement, automatic cleaning, automatic elimination of errors caused by bubbles using the volume difference method, and automatic drawing of standard curves. The injection speed is constant and can be adjusted according to the sample. Sample injector on computerEnd to endSettings, no need for users to individually set up the injector. User initiated detection allows for unmanned operation, reducing the workload for operatorsandThe system detection error caused by human injection error has improved work efficiencyAnd detection accuracy. During the testing process, parameters such as the number of tests, injection volume, and analysis time of the test sample can be modified at any time, with functions such as sample addition, replacement, and priority testing. |