SNH-PL-120LFully automatic high-pressure steam sterilizerProduct Features:
Safety improvement
Anti scald and mechanical injury: The internal locking tongue is embedded inside the sterilizer to avoid the risk of operator scratching or scalding caused by the traditional protruding outer claw structure (especially in high temperature conditions)
Anti misoperation mechanism: The internal locking tongue is usually linked with pressure/temperature sensors to physically lock when the pressure or temperature in the sterilization room has not dropped to a safe range, eliminating the risk of human misoperation; The external claw locking relies on manual judgment, which poses a risk of operational errors
Enhanced sealing: The internal locking tongue design ensures a tighter fit between the door body and the sealing ring, reducing the risk of steam leakage due to internal pressure fluctuations during high-pressure sterilization and minimizing the risk of burns and contamination
SNH-PL-120LFully automatic high-pressure steam sterilizerTechnical Specifications:
Parameter properties |
serial number |
Specific technical (parameter) requirements |
1 |
1. Capacity: ≥ 120 liters; |
|
2 |
2. Sterilization chamber material: ≥ SUS30408 stainless steel; |
|
3 |
3. Power: ≥ 3500W (220V voltage); |
|
4 |
4. Temperature range: Sterilization temperature: 105-138 ℃ or wider, dissolution temperature: 60-100 ℃ or widerwide rangeInsulation temperature: 45-65℃, |
|
5 |
5. Time range: Sterilization time: 1-9999 minutes, melting time: 1-9999 minutes or a wider range,holding time: 1-9999 minutes or wider range; |
|
6 |
6. Pressure gauge display range: -0.1-0.5MPa or wider. |
|
7 |
7. Equipped with a backend testing program: The user administrator enters the password to enter the backend program, which can be used for testingOvervoltage protection device for periodic testing instruments; |
|
8 |
8. Equipped with a dual over temperature and over pressure protection system: using a safety valve and an over pressure protection system for dual pressure protection, in case of abnormal pressure, pressure relief, and power outage protection; |
|
9 |
9. Equipped with automatic exhaust function: a nine level adjustable exhaust system that flexibly selects exhaust temperature and frequency according to different load requirements (such as liquid and solid); |
|
10 |
10. 4.3-inch color screen+physical button dual operation mode: balancing intuitive touch and reliability of physical buttons More convenient operation Having a state flowchart to display the process; |
|
11 |
11. Timer start function: Beijing time can be pre-set, and the sterilizer can be scheduled to start sterilization according to the scheduled time; |
|
12 |
12. Safety devices: self sensing pressure interlock device, wall over temperature protection system, heating tube dry burning protection system, overvoltage protection, sterilization temperature (over limit) protection, sterilization water level monitoring (unable to start due to water shortage), equipped with safety valve, overcurrent and short circuit protection system, closed lid inspection system, leakage protection device, anti scald safety protection, automatic fault detection system; |
|
13 |
13. Operation mode: It has the following six fixed modes: AOO liquid (heating sterilization exhaust) BOO liquid+insulation (heating sterilization exhaust insulation) COO dissolution (melting insulation) DOO instrument (heating sterilization exhaust) EOO instrument+drying (heating sterilization exhaust drying) FOO waste (heating sterilization exhaust) and can create new programs and store them in memory. Each program can create up to 20 programs, which will not be lost even if the power is turned off; |
|
14 |
14. Complete machine warranty ≥ two years; |
|
15 |
15. Configuration: One host, with at least 2 stainless steel baskets; |
|
16 |
16. Services: including assisting the purchaser in obtaining the Special Equipment Use Registration Certificate; |
|
17 |
17. Adopting a hood level motor and fan blades, equipped with an air convection and breeze device, it automatically starts after sterilization to accelerate cooling; |
|
18 |
18. Embedded locking structure:The force direction of the internal locking tongue is consistent with the pressure direction inside the sterilization chamber, and the locking force increases with the increase of pressure (similar to the "self-locking effect"); Ensure a higher degree of fit between the upper cover and the imported seal, achieve good sealing performance, and physically lock when the temperature has not dropped to a safe range, eliminating the risk of human error in opening; |
|
19 |
19. Having the function of recording unexpected power outages: After the power is restored, the screen displays "power outage during operation", requiring re sterilization to ensure the integrity of the experiment; |
|
20 |
20. Dimensions: Length ≥ 680mm, width ≥ 578mm, height ≥ 1258mm; |
|
21 |
21. Inner cavity size: 400mm * 968mm; |
|
warranty period |
: |
From the date of installation and acceptance: 2-year warranty (24 natural months) |