1Fujian High and Low Temperature Test Chamber Constant Temperature and Humidity ChamberProduct Usage:
A constant temperature and humidity chamber is a device used to test the performance of materials in various environments and to test the heat resistance, cold resistance, dry resistance, and moisture resistance of various materials. Suitable for quality testing of electronic, electrical, communication, instrument, vehicle, plastic products, metal, food, chemical, building materials, medical, aerospace and other products.
2、 Fujian high and low temperature test chamber constant temperature and humidity chamber meets the standards:
GB/T2423.1-2008 Test A: Low temperature test method; GB/T10589-2008 Technical Conditions for Low Temperature Test Chamber;
GB/T2423.2-2008 Test B: High temperature test method GB/T11158-2008 Technical conditions for high temperature test chamber;
GB/T2423.3-2006 Test Cab: Constant Damp Heat Test Method; GB/T10586-2006 Technical Conditions for Damp Heat Test Chamber;
GB/T2423.4-2008 Test Db: Alternating Damp Heat Test Method; GB/T10592-2008 Technical conditions for high and low temperature test chambers;
GB/T2423.22-2002 Test N: Temperature Change Test Method; GJB150.3 High temperature test;
IEC60068-2-1:2007 Low temperature test chamber test method; GJB150.4 Low temperature test;
IEC60068-2-2:2007 High temperature test chamber test method; GJB150.9 Damp Heat Test;
IEC68-2-1 Test A: Cold; IEC68-2-2 Test B: Dry Heat;
IIIFujian High and Low Temperature Test Chamber Constant Temperature and Humidity ChamberControl features:
☆ Adopting imported 7-inch true color touch screen, the screen display is intuitive Easy to operate, capable of setting values and program control, with a user-friendly and interactive human-machine interface for operation and control.
☆ 250 sets of 12500 segments storage, 250 days of historical data saving function
☆ Pre order power on/off function, end planning settings, automatically save data curves during power outages, etc
☆ Standard USB/RS-32 interface, download test data curves, copy data, and automatically generate Excel spreadsheets for easy analysis
☆ Optional LAN remote control function can be added
4Fujian high and low temperature test chamber constant temperature and humidity chamber structural characteristics:
☆ Updated and optimized design, saving space and allowing for placement in even small laboratories
☆ Large observation window for stronger visualization of product testing
☆ Large water storage capacity, long testing time, drawer style structural design for easy cleaning
Multiple safety protection measures ensure the safety of samples and equipment.
☆ Easy to operate and maintain
5Freezing system:
Modular refrigeration system, high efficiency, easy installation and maintenance
Separate the waterway distribution panel to reduce the safety hazards caused by waterway faults on electrical appliances
☆ Adopt water immersion leak detection method to detect leaks and eliminate potential leakage problems
☆ Adopting DuPont R404A and R23 environmentally friendly refrigerants from the United States, with no pollution
The refrigeration system and electronic control system have multiple safety protection mechanisms
VITechnical advantages:
☆ Independently developed control system, automatic load analysis and reasonable adjustment of refrigerant flow, saving energy and electricity by 30% year-on-year
☆ Low temperature continuous operation for 1000H without frosting technology
seven、Fujian High and Low Temperature Test Chamber Constant Temperature and Humidity ChamberSpecification parameters:
model |
TD-R type and non-standard |
||||||||||
30 |
80 |
120 |
150 |
225 |
306 |
408 |
800 |
1000 |
|||
temperature range |
-70℃~150℃(S), -40℃~150℃(L),-20℃~150℃(R),0℃~150℃(B), 常温~150 ℃(A) |
||||||||||
humidity range |
20% to 98% R.H (low humidity type: 10% to 98% R.H/5% to 98% R.H) |
||||||||||
Temperature/humidity fluctuation |
≤±0.5℃ / ≤±2% R.H |
||||||||||
Temperature/humidity uniformity |
≤±2℃ / ≤±3% R.H |
||||||||||
warm-up time |
About 3-4 ℃/min |
||||||||||
Cooling time |
About 1 ℃/min (special requirements can be customized: fast temperature variant 5 ℃~25 ℃/min adjustable) |
||||||||||
|
inner dimensions (CM) |
H |
35 |
50 |
60 |
60 |
75 |
85 |
85 |
100 |
100 |
|
W |
30 |
40 |
50 |
50 |
50 |
60 |
60 |
100 |
100 |
||
D |
30 |
40 |
40 |
50 |
60 |
60 |
80 |
80 |
100 |
||
|
external dimensions (CM) |
H |
130 |
143 |
153 |
153 |
168 |
178 |
178 |
193 |
193 |
|
W |
90 |
100 |
100 |
100 |
100 |
110 |
110 |
150 |
150 |
||
D |
75 |
85 |
85 |
95 |
105 |
105 |
125 |
125 |
145 |
||
material |
Outer box: Stainless steel with high-grade baking paint or SUS 304 # pattern treatment Inner box: SUS 304 # 8K mirror stainless steel plate |
||||||||||
refrigeration system |
French (Taikang) fully enclosed compressor unit, with a heat dissipating fin evaporator serving as a dehumidifier; Normal temperature+20~150 ℃ (A) model without refrigeration system |
||||||||||
heating system |
Stainless steel finned heating tube for heating air |
||||||||||
safety protection |
Compressor overcurrent, overpressure, oil pressure, no fuse overload protection, heating, box overheating, water tank shortage alarm system |
||||||||||
Standard Configuration |
Observation window, test hole (¢ 50x1), sample holder (2 sets), over temperature protector, observation light for the window, time signal interface |
||||||||||
Power (KW) |
4.5 |
5.8 |
6.5 |
7.2 |
8.2 |
9.5 |
12.5 |
13 |
14 |
||
Weight (KG) |
260 |
280 |
300 |
330 |
400 |
450 |
550 |
600 |
650 |
||
|