Fuhua Battery GFM-2000 Uninterruptible Power Supply UPS Valve Controlled Maintenance free EPS DC Screen Coal Mine Wind Power Emergency Energy Medical Communication Imported Special Equipment Battery
Shanghai Fuhua Protection God Power Co., Ltd. is a subsidiary of Shanghai Fudan Fuhua Technology Co., Ltd. It is a technology-based enterprise restructured from Fudan University Science and Technology Development Corporation. It was successfully listed on the Shanghai Stock Exchange in 1992 and became a Chinese high-tech joint-stock listed company.
Shanghai Fuhua has formed a large enterprise scale in the fields of power supply and electrical appliances (UPS, Battery) industry, software information technology, modern biopharmaceuticals, and park real estate development. The company has a total of 2000 employees, 3 manufacturing bases, 2 research and development centers, and 1 software export base, achieving industrial innovation and development of the company.
Since entering the power supply industry in the mid-1980s, Shanghai Fuhua has relied on Fudan University and the background of a listed company. With its talent, technology, and capital advantages, it has made significant progress in the research and development, large-scale production, and market expansion of uninterruptible power supply UPS and valve regulated sealed battery (VRLA battery) products. It is one of the starting and large-scale professional power supply manufacturers in China.

Model: GFM series
Power: GFM2V-200AH~GFM2V-3000AH
Fuhua Battery GFM Series Product Description
Operating temperature range: -20 ℃+45 ℃
Charging method: Recommended constant voltage and current limiting
Floating voltage: 2.23~2.27V (2.27 to 2.3VDC) @ 25 ℃
樶High charging current: 0.25C10 ampere @ 25 ℃
Capacity retention rate: greater than 97% per month @ 25 ℃
Shell material: ABS (flame retardant ABS material optional)
Design lifespan: 2V standard series float charging lifespan of 10-12 years @ 25 ℃
1. Good safety performance: no electrolyte leakage, no battery expansion or rupture under normal use.
2. Good discharge performance: stable discharge voltage and smooth discharge platform.
3. Good vibration resistance: The charged battery is fixed and vibrated at a frequency of 16.7HZ for 1 hour with an amplitude of 4mm, without leakage, battery expansion or rupture, and open circuit voltage
Normal.
4. Good impact resistance: The charged battery naturally falls from a height of 20CM onto a 1cm thick hardwood board three times without any leakage, battery expansion or rupture, and the open circuit voltage is normal.
5. Good resistance to over discharge: At 25 degrees Celsius, the charged battery is discharged with a constant resistance for 3 weeks (the resistance is only equivalent to the required resistance of the battery's 1CA discharge) to restore its capacity
The quantity is above 75%
6. Good charging resistance: At 25 degrees Celsius, the charged battery can be charged at 0.1CA for 48 hours without any leakage, battery expansion or rupture, normal open circuit voltage, and high capacity retention rate
95%
7. Good resistance to high current: A battery in a charged state can be discharged for 5 minutes at 2CA or for 5 minutes at 10CA. The non-conductive part is melted and there is no visible deformation. detailed introduction


·High weight and volume to energy ratio, low internal resistance, and high output power
·Low self discharge, with an average monthly self discharge rate of no more than 3% at 20 degrees Celsius
·Unique formula, excellent deep discharge recovery performance
·Using high-purity raw materials and strict production process control to ensure good performance of all product indicators
·The sealing reaction efficiency of the corrosion-resistant calcium lead tin alloy grid designed by computer precision significantly extends the service life of the battery
·Fully charged factory, easy to use, safe and explosion-proof
Widely used in power stations and plants, railways, substations, solar energy, IT/telecommunications, power supply/industry, safety lighting, emergency power supply, engine starting/switching power supply, signal equipment and ship power supply equipment, UPS, etc.
more
Technical data for batteries - Maintenance of batteries:
Lead acid batteries'>Battery maintenance '>The quality and storage of lead-acid batteries not only directly affect their quality and lifespan
Life also affects the safe use of electricity for starting equipment and the completion of work tasks. Therefore, the maintenance and storage of batteries are
The use of batteries is an important task for sales personnel.
The maintenance of lead-acid batteries is divided into daily maintenance and regular maintenance. Daily maintenance refers to the maintenance in daily work
Protecting is a fundamental and effective task in battery maintenance. Regular maintenance is for batteries
In different situations, certain maintenance projects can only be carried out at charging stations on the basis of good daily maintenance work,
Only by combining regular maintenance can the maintenance work of the battery be done well.
⑴ Daily maintenance
① Regularly keep the surface of the battery clean. If dust is found on the surface, it should be wiped promptly
You can first wipe it with a cloth dipped in soda water, and then rinse it off with clean water;
② Regularly clean the exhaust plug with distilled water to maintain good ventilation;
③ Charge, discharge, and recharge the battery according to regulations;
④ During the charging process, the temperature of the electrolyte should not exceed 45 ℃ to prevent overcharging;

After sales service for batteries:
We establish a 'Customer Profile' for the batteries sold and provide tracking services.
After the battery is sold, it should be tracked by phone at any time and inspected at least once a year, and the usage of the battery should be reported to customers to ensure their peace of mind.
3. Provide solutions when customer complaints occur. Including on-site recovery plan and return handling plan until customer satisfaction. The aim is to minimize customer troubles.
Under normal circumstances, 24-hour customer service is available to solve various construction problems for customers.

User Receipt Notice:
1. When you collect a package from a courier company or logistics staff, be sure to check the goods on the spot to see if they are in good condition. Do not package them properly, just sign for them directly. Check that the goods are in good condition before signing for them;
2. Confirm that the outer packaging is free from obvious flattening, holes, scattering, moisture, and no signs of unsealing before signing for it;
3. If encountering the above situations, please open and check on the spot whether the goods are intact, whether they can be used normally, and whether the quantity and variety are complete;
UPS battery installation:
Firstly, it is necessary to check whether the battery model, quantity, and connecting wires match the model used. If there are any deviations, please contact our company as soon as possible.
2. Metal tools such as torque wrenches and wrenches should be insulated with plastic tape before use to prevent situations such as short circuits, battery damage, and fire and explosion.
3. When connecting, please pay attention to the correct polarity, tighten the bolts to ensure good contact, but do not apply too much force to avoid damaging the terminals and causing leakage.
4. It is not allowed to install batteries of different manufacturers, capacities, and performances together for use. New and old batteries cannot be mixed; Mixing different batches of batteries should be limited to one month; Before use, it is necessary to check the open circuit voltage of the battery. If the voltage of a 12V battery is lower than 12.40V, a 6V battery is lower than 6.20V, or a 2V battery is lower than 2.0V, the battery should be charged first. The charging voltage should refer to the balanced charging method.
Before installing the end connectors and conducting the battery, the total voltage of the battery system and the connection of the positive and negative electrodes should be checked to ensure correct installation.
6. Protect the battery from strong vibrations or impacts.

Sales product type:
UPS power supply: Shante, four-way APC、 Many general agents such as Coaster, Emerson, Eaton Merlin Gerin, Koch, Delta, Airtech, Lecco, Golden Warrior, Yishite, etc
Batteries: Panasonic, Yuqian, Ailide, Saite, Toyo, Coaster, Hercules, Shengyang, Kedian, Aipex, Kehua, Coaster, etc.