- Phone
-
Address
No. 226, West Section of Gaodian Road, Hongguang Town, Pidu District, Chengdu City
Chengdu Lingdu Instrument Co., Ltd
No. 226, West Section of Gaodian Road, Hongguang Town, Pidu District, Chengdu City
Food Security Rapid Inspection Instrument
Food security rapid inspection instrument (heavy metals, fungal toxins)Product Features:
The instrument can simultaneously detect heavy metal (quantitative) and fungal toxin (quantitative) indicators in food raw materials such as grains, grain products, and feed.
Food security rapid inspection instrument (heavy metals, fungal toxins)Other features:
1.It has a rapid detection and analysis method using immunochromatographic colloidal gold, which can be extended to detect pesticide residues.
2.Built in operating system, integrated computer control, energy consumption ≤15WThe detection data can be sent to the network or data platform.
3.Built in wireless transmission module,USBInterface,RS232Interface,Ethernet portData can be transmitted through wireless and wired connections.
4.Weight of the detector3.0kg, 7Inch color resistive touch display screen, memory ≥2.05GBBuilt in micro printer.
5.220Vpower
6.Complete database functionality (real-time display, storage)Test resultsThe colloidal gold detection card module stores records such as detection time, detection unit, detection personnel, detection items, sample number, detection results, reference values, etc., including analysis, export, printing, and processing of detection data.
7.Immunoassay colloidal gold detection module
(1)By using scanning imaging technology and immunochromatographic colloidal gold technology, heavy metals (cadmium, lead) and fungal toxins can be achieved(AflatoxinB1Vomit toxin, zearalenoneOchratoxinAFumonisin toxinB1TheT-2Rapid quantitative detection and analysis of toxins;
(2)Detecting card slot: ≤8×2×0.5cmDetection method: scanning, scanning accuracyCV≤1%Detection time ≤5Seconds, measurement repeatability ≤3%Light source: independent stable constant current light source, detector: ultra sensitive photoelectric sensor.
(3)Standard curve input method: Each batch of detection card reagent kit is equipped with a standard curveIDCard, standard curve input adopts automatic reading, and the detection process does not require the preparation of standard or quality control samples for calibration;
(4)The detection card is designed using a two-wire method to quantitatively measure precision(cv)Detection card batch is less than15%Between batches less than20%The detection card is individually packaged in plastic single card and has an expiration date of storage at room temperature6Valid for one month,2-8℃保存1Effective annually;
(5)Unified pre-treatment methods: Unified pre-treatment methods for heavy metals cadmium and lead, and aflatoxinB1, zearalenone, vomitoxin, ochratoxinAFumonisin toxinB1TheT-2The pre-treatment method for toxins is unified, and can be extracted and tested separately at once to improve efficiency;
(6)Heavy metals cadmium, lead, and mycotoxins (aflatoxins)B1Vomit toxin, zearalenone, ochratoxinA)Testing products with a grain systemProduct evaluation report of testing institution, including aflatoxinB1Vomit toxin and zearalenone have passed the evaluation of the National Grain Administration's Standard Quality Center.
8.Constant temperature incubator
(1)Adopting horizontal chromatography incubation method to reduce operational errors;
(2)The incubation card slot adopts a fully enclosed design with multiple card slots6Number of incubation wells6One, temperature control:37℃, temperature control accuracy ≤0.5℃, heating rate ≤10minTemperature uniformity ≤0.3℃, real-time temperature display accuracy:0.1℃。
9.oscillator
(1)Oscillation mode: Multiple modes of circular mixing, can trigger jog operation, oscillation speed0-2500rpm/min;
(2)Can oscillate and extract simultaneously8A sample, without the need for operators to fix the sample for oscillation during operation.
10.Mini centrifuge: Speed:1000—12000rpmVolume: ≤20×18×13cmWeight: ≤1.5kg.
11.Crusher: Power≥0.15 kilowatt Broken particle size: less than0.15mmThe broken samples have basically passed 20 Mesh sieve.
12.Electronic scale: Range:0~200g, division value:0.01gStainless steel weighing platform,LCDmonitor.
13.Pipette:100~1000µLpipette 1Support,20-200µLpipette 1Support.
Food security rapid inspection instrument (heavy metals, fungal toxins)Test items
| serial number | project | detection limit | Testing Scope |
| 1 | Heavy metal cadmium | 0.02ppm | 0-1ppm |
| 2 | Heavy metal lead | 0.02ppm | 0-1ppm |
| 3 | AflatoxinB1 | 1ppb | 0-150ppb |
| 4 | Vomiting toxin quickly | 0.1ppm | 0-6ppm |
| 5 | 玉米赤霉烯酮 | 10ppb | 0-1500ppb |
| 6 | OchratoxinA | 1ppb | 0-150ppb |
| 7 | Fumonisin toxinB1 | 0.1ppm | 0-60ppm |
| 8 | T-2toxin | 0.1ppm | 0-5ppm |
14.other
(1)Aluminum alloy casing,17kg, pull rod portable;
(2)Warranty: After product acceptance1Within the year (main equipment testing equipment and constant temperature incubator)3Within the year, free maintenance or replacement will be provided, and lifetime maintenance services will be offered after the warranty period expires;
(3)After sales: Provide one free on-site training, online answers48On site service within hours.
(4)Quick inspection box configuration table
| serial number | Accessory name | specification | unit | quantity |
| 1 | detector | - | platform | 1 |
| 2 | Constant temperature incubator | at least6aIncubation tank | platform | 1 |
| 3 | test tube rack | 1.5The15mlCentrifuge tube rack | a | 1 |
| 4 | Small powder grinder | - | platform | 1 |
| 5 | Vortex mixer | Simultaneously automatically process at least8A sample | platform | 1 |
| 6 | Small scale balance | precision0.01g | platform | 1 |
| 7 | pipette gun | 1mL | branch | 1 |
| 8 | pipette | 200ML | branch | 1 |
| 9 | Suction head box | 1mL | a | 1 |
| 10 | Suction head box | 200ML | a | 1 |
| 11 | Three channel timer | - | a | 1 |
| 12 | centrifuge | - | platform | 1 |
| 13 | box | - | a | 1 |