E-mail
18948326615@163.com
-
Phone
18948326615
-
Address
504 Beiditianfang, Futian Street, Futian District, Shenzhen
Shenzhen Huizhong Zhilian Electronic Technology Co., Ltd
18948326615@163.com
18948326615
504 Beiditianfang, Futian Street, Futian District, Shenzhen
Fully comply with A-level requirements:Conduct testing in accordance with the strict IEC 61000-4-30A international standard
GPS time synchronization:Accurately associate data with events or datasets generated by other tools
Flexible and fully configurable threshold and scale coefficients:Users can define detailed interference detection and recording standards to identify specific issues.
Uninterruptible power supply (maintain for 40 minutes):Not missing any important events - even recording the occurrence and end of interruptions and shutdowns, which helps identify the root cause of the problem
10 MHz, 6000 Vpk waveform capture:Even detailed maps of the shortest events can be captured
2 GB data storage:Can perform long-term and detailed synchronous recording of numerous electrical energy parameters
Comes with a complete set of software:Provide trend charts in online mode for fault root cause analysis, statistical summary, written reports, and real-time data monitoring.
Plug and play:Allow the use of automatic sensor detection function for quick settings; The sensor is powered by the recorder and does not require a battery
Durable and sturdy on-site design:The insulated housing without rotating components and sturdy design can be reliably tested on site under almost any conditions.
Meets the strictest A-level standards for power quality testing
The Fluke 1760TR Basic three-phase power quality recorder fully complies with the IEC 61000-4-30A standard, making it ideal for advanced power quality analysis and unified standard testing. This power quality monitoring tool is designed to analyze the distribution systems of public welfare and industry in medium and low voltage power grids, allowing users to flexibly customize thresholds, algorithms, and measurement options. The 1760 electric energy recorder can capture the most detailed information of the parameters selected by the user.
application
Detailed interference analysisPerform rapid transient analysis to identify the root cause of equipment failures for future improvement and preventive maintenance. The fast transient option and 6000 V range enable it to capture very brief pulses (such as lightning strikes).
Meets the A-level service quality requirements- Verify the power quality at the inlet. With A-level standard certification, Fluke 1760 allows for various rigorous verifications.
Event correlation at multiple locationsBy utilizing the GPS time synchronization function, users can quickly detect the location of the first malfunction (inside or outside the facility).
Electrical isolation and DC coupling- Allow comprehensive measurement of different electrical energy systems. For example, solving UPS system faults by synchronously recording battery voltage and power output.
Analysis of Power Quality and Power LoadAssess the basic power quality before installation to ensure compliance with critical system requirements; And verify the capacity of the power system before increasing the load.
Provide four Fluke 1760 models:
Product features |
Fluke 1760 basic model |
Fluke 1760TR basic model |
Fluke 1760 |
Fluke 1760TR |
Electricity quality statistics in accordance with EN50160 standard |
• |
• |
• |
• |
List of voltage events (voltage dip, surge, and interruption) |
• |
• |
• |
• |
Continuous recording: | ||||
voltage |
• |
• |
• |
• |
current |
• |
• |
• |
• |
Electric energy P, Q, S |
• |
• |
• |
• |
power coefficient |
• |
• |
• |
• |
kWh |
• |
• |
• |
• |
Flicker |
• |
• |
• |
• |
imbalance |
• |
• |
• |
• |
frequency |
• |
• |
• |
• |
Voltage and current harmonics (up to 50th)/interharmonics |
• |
• |
• |
• |
THD |
• |
• |
• |
• |
power signal |
• |
• |
• |
• |
trigger record |
• |
• |
• |
• |
Online mode (oscilloscope, transient and event) |
• |
• |
• |
• |
Fast transient analysis up to 10 MHz |
• |
• |
||
4. 600V voltage probe |
• |
• |
||
4 dual range flexible current probes (1000 A/200 A ac) |
• |
• |
||
GPS time synchronization receiver |
• |
• |
||
存储器 |
2 GB flash memory |
|||
Overview of Measurement Functions | ||
Statistical evaluation |
The power quality statistics comply with EN50160 standards and DISDIP tables, such as ITIC, CEBEMA, and ANSI |
|
Event List |
Detect voltage dips, surges, and interruptions and store them in the event list. Meanwhile, any initiated trigger will generate an event and be added to this list. |
|
The event list displays the accurate time, duration, and magnitude of the event occurrence. These events can be classified based on several attributes, and one of them can be selected for further root cause analysis of the fault. | ||
If the trigger is activated, it can store true effective (RMS) values, transients, and fast transients. | ||
Continuous recording |
Fluke 1760 records the RMS values and corresponding minimum and maximum values of the following parameters: |
|
trigger record |
valid value |
The accumulation time can be adjusted between 10 ms (1/2 cycle), 20 ms (1 cycle), 200 ms (10/12 cycles), or 3 seconds (150/180 cycles). |
The calculation of RMS value, harmonics, and interharmonics is synchronized with the power frequency. | ||
The basic accumulation time of harmonics and interharmonics is 200ms | ||
oscilloscope |
All 8 channels have a sampling rate of 10.24 kHz |
|
Fast Transient |
The sampling rate for fast transient 1-4 FFT channels can be selected from 100 kHz to 10 MHz |
|
power signal |
Phase and N-wire, voltage and current |
|
Online Mode |
Variable refresh rate. This feature allows users to verify instrument settings and quickly browse oscilloscopes, transients, and events. |
|
General data | ||
Inherent uncertainty |
Please refer to the reference conditions and provide a two-year guarantee |
|
quality system |
Developed and manufactured according to ISO 9001:2000 |
|
environmental conditions |
Operating temperature range |
0 ° C to+50 ° C; 32 ° F to+122 ° F |
Working temperature range |
-20 ° C to+50 ° C; -4 ° F to+122 ° F |
|
Storage temperature range |
20 ° C to+60 ° C; -4 ° F to 140 ° F |
|
reference temperature |
23 °C ±2 K; 74 °F ±2 K |
|
Climate grade |
B2 (IEC 654-1), -20 ° C to+50 ° C; -4 ° F to+122 ° F |
|
Maximum working altitude |
2000 m: maximum 600 V CAT IV ¹, power supply: 300 V CAT III 5000 m: maximum 600 V CAT III ¹, power supply: 300 V CAT II |
|
1. Depending on the sensor | ||
Reference conditions |
ambient temperature |
23 °C ±2 K; 74 °F ±2 K |
power supply |
230 V ±10% |
|
power frequency |
50 Hz / 60 Hz |
|
signal |
The nominal input voltage Udin indicated |
|
average |
10 minute interval |
|
shell |
Insulated and sturdy plastic casing |
|
Electromagnetic Compatibility (EMC) |
Radiation standards |
Class A, compliant with IEC/EN 61326-1 standard |
Anti-interference ability |
IEC/EN 61326-1 |
|
power supply |
range |
Communication: 83 V to 264 V, 45 to 65 Hz |
DC: 100 V to 375 V | ||
security level |
IEC/EN 61010-1 2nd edition |
|
300 V CAT III | ||
power consumption |
Nickel hydrogen, 7.2 V, 2.7 hours |
|
battery pack |
If there is a power failure, the built-in battery can continue to supply power for up to 40 minutes. Afterwards, or when the battery is depleted, Fluke 1760 will shut down; After the power supply voltage is restored, the latest settings can be used to continue measuring. Users can replace the battery themselves. |
|
display screen |
The Fluke 1760 is equipped with LED indicator lights that indicate the following statuses: 8 channels, phase sequence, power (power or battery), memory usage, time synchronization, and data transfer. |
|
Power indicator light |
Long on: The power supply is working properly. Extinguish: In the event of a power failure, power is supplied through the internal battery. |
|
The 3-color indicator lights for each channel are used to indicate |
Overload state Under load status |
|
Data storage device |
2 GB flash memory |
|
Memory mode |
linear |
|
interface |
Ethernet (100MB/s), compatible with Windows ® XP、 7 and 8 RS 232, External modem (via RS 232) |
|
The baud rate of RS 232 |
9600 baud to 115K baud |
|
Dimensions (height x width x depth) |
325 x 300 x 65 mm; 2.8 x 11.8 x 2.6 in |
|
weight |
Approximately 4.9 kg; 10.8 lbs. (without accessories) |
|
warranty period |
2 years |
|
Calibration interval |
For Class A, it is recommended to take 1 year, and for the other 2 years |
|
Signal conditioning | ||
50 Hz system range |
50 Hz ± 15% (42.5 Hz to 57.5 Hz) |
|
60 Hz system range |
60 Hz ± 15% (51 Hz to 69 Hz) |
|
resolution |
16ppm |
|
Sampling frequency of 50 Hz power supply frequency |
10.24 kHz, The sampling rate is synchronized with the power frequency. |
|
Uncertainty in frequency measurement |
< 20 ppm |
|
Uncertainty of internal clock |
<1s/day |
|
Measurement time interval |
Total interval values according to IEC 61000-4-30 Class-A |
|
Minimum and maximum values |
1/2 cycle, for example: 10 ms RMS value (50 Hz) |
|
Transient |
The sampling rate range for each channel is 100 kHz to 10 MHz |
|
harmonic |
Compliant with IEC 61000-4-7:2002 standard: 200 ms |
|
Flicker |
Compliant with EN 61000-4-15:2003 standard: 10 minutes (Pst), 2 hours (Plt) |
|
measurement input | ||
Input quantity |
8 current isolated inputs for voltage and current measurement. |
|
Sensor safety |
Maximum 600 V CAT IV (depending on sensor) |
|
Basic security level |
300 V CAT III |
|
Rated voltage (rms) |
100 mV |
|
Range (peak) |
280 mV |
|
Overload capacity (rms) |
1000 V (continuous) |
|
Voltage rise rate |
Maximum 15 kV/µ s |
|
input resistance |
1 MΩ |
|
input capacitance |
5 pF |
|
Input filter |
Each channel is equipped with a passive low-pass filter, an anti aliasing filter, and a 16 bit A/D converter. Synchronize with the universal quartz control clock pulse to sample all channels. |
|
uncertainty | ||
Uncertainty under reference conditions |
The uncertainty of the voltage sensor complies with IEC 61000-4-30 Class-A. All voltage sensors are suitable for direct current up to 5 kHz |
|
Sensor 1000 V |
0.1% Udin=480 V and 600 V P-N |
|
Sensor 600 V |
0.1% Udin = 230 V P-N |
|
Inherent uncertainty of harmonics |
Class I, compliant with EN 61000-4-7:2002 standard |
|
Reference conditions |
23°C ± 2 K < 60 % rH; 74°F ± 2 K < 60 % rH |
|
Preheating instrument>3 hours | ||
Power supply: 100 V to 250 V AC | ||
temperature drift |
100 ppm / K |
|
aging |
<0.05%/year |
|
Common mode rejection ratio |
>100 dB (at 50 Hz) |
|
temperature drift |
Due to temperature induced amplification changes:<0.005%/K |
|
aging |
Changes in growth rate due to aging:<0.04%/year |
|
noise |
Noise voltage, short circuit input:<40 µ V |
|
direct current |
± (0.2% RDG+0.1% sensor) |
|
Model/Name |
Instructions |
|
Fluke 1760TR Basic Topas Power Quality Recorder Equipped with 8 input channels (4 current/4 voltage channels or 8 voltage channels) |
·Built in flash memory 2 GB ·PQ analysis software included in the CD ·Ethernet cable for network connection (1) ·Cross linked Ethernet cable for direct connection to PC (1) ·Power cable (1) ·Operation Manual ·Portable bag ·Fast transient analysis up to 10 MHz
|
Accessories/Models |
Current clamp |
TPS CLAMP 10 A / 1 A |
TPS CLAMP 10 A/1 A clamp type current transformer |
TPS CLAMP 200 A / 20 A |
Fluke TPS CLAMP 200 A/20 A clamp type current transformer |
Accessories/Models |
other |
TPS current clamp 50 A/5 A |
Fluke TPS current clamp 50 A/5 A clamp type current transformer |
Accessories/Models |
current probe |
TPS FLEX 18 |
Fluke TPS FLEX 18 Flexible Current Probe |