Use the brand new Fluke 1750 three-phase power quality recorder and Fluke power analysis software to record three-phase power quality and monitor power quality fluctuations.

Product Details

Main features:

  • Satisfying the standard of electrical energy quality:All measurements comply with the IEC61000-4-30 standard to accurately evaluate all measurement values, including voltage, current, power, harmonics, and flicker

  • Fast and reliable configuration:The ARCHOS 43 Internet Tablet provides a window for the recorded content of the instrument, allowing for quick and reliable configuration even in challenging testing locations

  • No threshold setting:Applying thresholds after collecting data using Fluke energy analysis software - no need to worry about losing information due to incorrect settings

  • Capture all situations:Cross channel and current triggering functions capture every measurement on each channel at any time

  • Intuitive PC software:Easily analyze data and generate reports based on automated EN50160 reports and standards

  • Plug and play:By using a self identifying current probe and a single wire voltage connection, the setup can be completed in a few minutes

  • No need to reconnect the line:When the connection is incorrect, exchange internal channels with wireless PDA or PC

  • Measure each parameter:Voltage and current of phase, neutral line, and ground line

  • 5 MHz, 8000 Vpk waveform capture:Can capture detailed images of the shortest events

  • Quickly retrieve data:By using the included SD memory card or connecting via 100BaseT high-speed Ethernet. When the instrument has no other connections, the SD card contains automatically downloaded content


Product Overview:

Fluke 1750 Three phase Power Quality Recorder

Use the brand new Fluke 1750 three-phase power quality recorder and Fluke power analysis software to record three-phase power quality and monitor power quality fluctuations. These power meters work 24/7 and can automatically record every power quality parameter and event in each cycle.

application
Long term analysis:
Identify difficult to detect or intermittent issues; Monitor key equipment, capture power quality events, and link them to equipment failures
Power quality investigation:Quantify the power quality of each part of the entire facility and record the results through professional reports
Meets quality requirements:Verify the input power quality at the inlet
Equipment installation/debugging:Set performance benchmarks for the electrical energy system before installation to ensure compliance with quality requirements

Fluke 1750 三相电能质量记录仪.jpg

Technical Specifications

Power Quality Measurement Standards

compliance

IEC 61999-1-4 Class 1, IEC 61000-4-30 (Class A, S or B, depending on the measurement function), IEEE519, IEEE1159, IEEE1459 and EN50160

Clock/Calendar

24-hour clock, leap year

Real time clock accuracy

The error shall not exceed ± 1 second/day

Memory data capacity

At least 2 GB

The longest recording period

At least 31 days

Measurement time control

automatic

Maximum number of events

Due to memory size limitations

Power requirements

100 to 240 V RMS ± 10%, 47-63 Hz, 40 W

Running time during interruption (internal UPS operation)

Each interruption lasts for 5 minutes, with a total working time of 60 minutes and no charging

size

215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)

weight

6.3 kg (14 lb)

input

Measurement type

Single phase with neutral wire, single-phase IT without neutral wire, single-phase phase division, three-phase Y-shape, three-phase triangle, three-phase IT, three-phase high leg arm, three-phase open leg arm, binary triangle, and 21/2 element Y-shape

input channel

Voltage: 4-channel, AC/DC

Current: 5 channels

Voltage channel

Input impedance: 2 M Ω

Input capacitance:<20 pF

Current input characteristics

2 V effective value=full range, the input resistance of clamp CT is 1 M Ω, and the resistance of flexible Flexi CT is relatively low

measurement method

Simultaneously perform digital sampling on voltage and current. Internal frequency reference during digital PLL synchronous sampling and voltage drop

Synchronization and Sampling

PLL synchronization source

PLL synchronizes the A-N voltage of Y-shaped connection type and the A-B voltage of triangular connection type. All listed connection types can be classified as Y-shaped or triangular.

PLL lock range

42.5 to 69 Hz

sampling frequency

Voltage and current: 256 samples per cycle; Interharmonics in accordance with IEC 61000-4-7 standard: 2560 points/10 cycles (50 Hz); 3072 points/12 cycles (60 Hz); Transient voltage: 5 MHz

A/D resolution:

Voltage and current: 24 bits

Transient voltage: 14 bits

Voltage and current measurement

Voltage measurement range

AC voltage: 1000 V rms ± 10% out of range

DC voltage: ± 1000 V rms ± 10% out of range

Voltage peak coefficient

3 or lower

Current measurement range

Depending on the current probe used

Current Crest Factor

4 or lower

RMS voltage

Measurement type

Continuous calculation of true effective value: every cycle, every 1/2 cycle, and every 10 or 12 cycles, with frequencies of 50 or 60 Hz respectively, in accordance with the requirements of IEC 61000-4-30 standard.

Measurement uncertainty

Communication: ± 0.2% reading ± 0.1% full scale, above 50 V rms

DC: ± 0.5% reading ± 0.2% full scale, greater than 50 V DC

RMS current

Measurement type

Continuous calculation of true effective value: According to the standard, at a frequency of 50 or 60 Hz, for each cycle, every 1/2 cycle, and every 10 or 12 cycles, respectively

Transient voltage (pulse)

Measurement type

Waveform sampling

full scale

8000 V pk

Sampling resolution

200 nS

Measurement uncertainty

± 5% reading ± 20 V (test parameters: 1000 V DC, 1000 V RMS, 100 kHz)

Voltage temporary rise (significant increase in effective value)

Measurement type

True RMS (calculated by overlapping every half cycle - line voltage measurement is applicable to 3P3W lines, phase voltage measurement is applicable to 3P4W lines)

Displayed data

The amplitude and duration of temporary rise

measurement

Same as the effective voltage value

Voltage sag (effective value drop)

Measurement type

True RMS (calculated by overlapping every half cycle - line voltage measurement is applicable to 3P3W lines, phase voltage measurement is applicable to 3P4W lines)

Displayed data

The amplitude and interval of temporary decrease or interruption

measurement

Same as the effective voltage value

Voltage drop (interruption)

Measurement type

Same as voltage sag

LAN interface

connector

RJ-45

Speed and type

10/100 Base-T, Automatic MDIX

communication protocol

TCP/IP based on Ethernet

Wireless controller interface

connect

Wireless (2.4 GHz radio)

speed

Up to 700 kbit/s

communication protocol

Bluetooth SPP

power measurement

Electricity, battery life:

Measurement type

Continuous calculation of true effective value: According to the standard, at a frequency of 50 or 60 Hz, for each cycle and every 10 or 12 cycles, respectively

frequency

Measurement range

42.5 to 69 Hz

Measurement source

Same as PLL synchronization source

Measurement accuracy

± 10 mHz (10% to 110% of range, with sine wave)

power factor

Measurement range

0.000 - 1.000

Measurement accuracy

± 1 digit calculated from each measurement value (total value is ± 3 digits)

Displacement power factor

measurement method

Calculated by the phase difference between the fundamental voltage and current waves

Measurement range

-1.000 (leading) to+1.000 (lagging)

Measurement accuracy

± 0.5% reading ± 2% full-scale ± 1 digit

Voltage imbalance and phase sequence

measurement method

According to IEC 61000-4-30, positive sequence voltage divided by negative sequence voltage

Harmonic voltage and current

Analysis Window

rectangle

analysis frequency

1 to 50

Measurement accuracy

Voltage/current: 1st to 20th times: ± 0.5% reading ± 0.2% full-scale 21st to 50th times: ± 1% reading ± 0.3% full-scale (accuracy of current sensor must include current and power)

measurement method

IEC 61000-4-7

Inter harmonic voltage and current (intermediate frequency harmonics)

Analysis Window

rectangle

analysis frequency

1.5 to 49.5

measurement method

IEC 61000-4-7

Flicker

measurement method

IEC 61000-4-15

For Plt, 2 hours; For PSt, 10 minutes

Measurement range

0, 1 to 5 (25), depending on voltage level, modulation, and frequency

Environmental standards

Usage environment

working environment

Indoor or covered outdoor, with a maximum altitude of 2000 meters

Storage temperature and humidity

-20 ° C to 50 ° C, 80% maximum relative humidity, non condensing

Working temperature and humidity

0 ° C to 40 ° C, 80% maximum relative humidity, non condensing

Maximum rated operating voltage

voltage terminal

1100 V true effective value

Voltage resistance

Between the voltage input terminals, between the voltage input terminals and the current probe, between the voltage input terminals and the casing, 5550 V RMS AC, for one minute (50/60 Hz, 1 mA induced current)

Protection level

IP30 (according to EN 60529)

standard

Electromagnetic Compatibility (EMC)

EN 61326-1:1997+A1:1998 Class A

EN 61000-3-2:1995+A1:1998+A2:1998

EN 61000-3-3:1995

security level

EN 61010-1 2 nd Edition; 2 000

Voltage input device: Pollution level 2, overvoltage category 1000 V CAT III, 600 V CAT IV (expected overvoltage: 8000 V)

Model/Name

Instructions

Fluke 1750

Three phase electric energy recorder

·1750 collection equipment

· ARCHOS 43 Internet Tablet

·4-400A current probe (3140R)

·5 Test lines and clamps

·SD memory card

·Fluke Energy View and Fluke Energy Analysis Software

·Power cord with international plug kit

·Ethernet cable

·Color positioning kit

·Printed introductory manual

·Product CD, accompanied by software and PDF version of user manual

·CS 1750/1760 Durable Portable Soft Bag

Accessories/Models

Test wire

TLS430

Fluke TLS230- Test Line and Crocodile Clamp (4 Black and 1 Green)