E-mail
hjl_cqsz@163.com
-
Phone
13996473738
-
Address
No.1 Nanpingzheng Street, Nan'an District, Chongqing
Chongqing Shouzheng Technology Co., Ltd
hjl_cqsz@163.com
13996473738
No.1 Nanpingzheng Street, Nan'an District, Chongqing
Product Overview
The BYLDN-1-G fixed Doppler ultrasonic flowmeter is a durable, non-contact ultrasonic flowmeter for measuring sewage. It measures the flow rate of sewage inside the pipeline from the outside, and does not require pipe cutting or flow stoppage during installation. Therefore, it does not have the necessary flanges for general flowmeters, nor does it have problems such as medium leakage and pressure loss.
Fixed Doppler ultrasonic flow meters are mainly used for environmental testing of urban sewage treatment plants and drainage pump stations, as well as flow measurement of urban drainage, industrial wastewater, domestic sewage, mud, pulp, oil-water mixtures, etc. in industries such as mining, oil fields, metallurgy, chemical engineering, refining, papermaking, and food. Suitable for hard pipes such as steel and hard plastic pipes, it can measure two-phase liquids containing suspended solid particles or bubbles in pipes of various diameters and wall thicknesses.
Performance parameters:
|
project |
sex can ginseng number |
|
|
Lord machine |
Display |
1. Adopting a menu style prompt, it can display information such as instantaneous flow rate, cumulative flow rate, flow rate, etc 2. Display 5 lines x 10 Chinese characters (5 lines x 20 characters) in Chinese/English, with a display window with a large amount of information. |
|
Signal output |
Current signal: 4-20mA, with load capacity of 0~600Ω |
|
|
Relay output: upper and lower limit alarms can be set. |
||
|
Data interface: Standard RS-232C or RS-485 |
||
|
Data recording and playback function |
1. Built in data recording function, capable of storing 65072 data records. 2. Data playback function, Windows style graphical interface dedicated software,Data can be downloaded to a computer. It can display the instantaneous flow time curve waveform, providing a powerful tool for managers to analyze data. |
|
|
It has the function of accumulating annual, monthly, and daily traffic, which can record the accumulated traffic of the previous 5 years, the previous 12 months, the previous 31 days, and the current year, month, and day. |
||
|
sensor |
Installation method |
External binding type |
|
Insertion type (suitable for pipes with a diameter of DN150 or more) |
||
|
cable length |
6m, Optional maximum length of 299m |
|
|
Explosion-proof rating |
Exib ųBT4 |
|
|
Temperature |
Lord machine |
-20℃~50℃ |
|
sensor |
-40℃~82 ℃, high temperature sensor: -40 ℃~150℃ |
|
|
Pipeline condition |
pipe material |
Steel, stainless steel, cast iron, copper PVC、 Aluminum, fiberglass, cement, hard metal plastics, etc., with lining allowed |
|
Straight pipe section |
The installation point of the sensor should preferably meet the following requirements: upstream ≥ 10D, downstream ≥ 5D, and distance from the pump outlet ≥ 30D (D refers to the pipe diameter) |
|
|
Pipe diameter |
25mm~3000mm (inner diameter) |
|
|
measurement range |
0.3 m/s~8.0m/s、0.5 m/s8.~0m/s |
|
|
Accuracy |
± 1%, ± 2% |
|
|
repetitiveness |
±0.5% |
|
|
power supply |
AC85~It can work at 265V and is suitable for situations with harsh power supply voltage. |
|
|
Protection level |
IP67 |
|
|
housing dimensions |
ABS plastic 240 × 185 × 120 (mm) |
|
|
weight |
1.88Kg |
|