Fischer Coating Thickness Gauge from Germany

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Dualscope MP0R and Dualscope MP0R-FP are equipped with an integrated probe or an extended probe, suitable for measuring the thickness of coating layers on iron substrates.

Product Details

DUALSCOPE MP0R/ DUALSCOPE MP0R-FP


A pocket sized instrument with a PC interface that can conveniently and quickly measure almost all metalsThe coating thickness.

The DUALSCOPE measuring instrument can easily, quickly, and non destructively measure coating thickness, and has the same accuracy as all Fischer instruments.
The shape and magnetic permeability of the sample have a relatively small impact on the measurement results. This instrument has a conductivity compensation function for non-magnetic substrates.
According to the measurement specifications of IMO PSPC (90/10 Rule) and SSPC-PA2, two special measurement modes with appropriate preset values are helpful for measuring anti-corrosion coatings.
The compact size, sturdy and durable instrument design, and lightweight weight make it an ideal choice for on-site applications. Two LCD displays allow reading of measurement values from various measurement positions.
By using the accompanying FISCHER DataCenter software, measurement data can be transmitted to a PC and easily and quickly evaluated. Custom inspection reports can be created, printed, and archived. In addition, each instrument comes with a manufacturer's certificate.

Main Features

measurement method Magnetic induction method (ISO 2178, ASTM D7091, Measurement of non-magnetic coatings on magnetic substrates);
Eddy current method (ISO 2360, ASTM D7091, Measurement of non-conductive coatings on non-magnetic base metals);
Automatically select the measurement method corresponding to the substrate.
probe probetopRadius: 2 millimeters (78 miles); Probe material: Hard alloy
data storage *10000 high readings; Even without a battery, the contents of the memory can be retained
Measurement frequency More than 70 measurements per minute
Measurement and collection Automatically after placing the probe; The beep sound and green LED indicate the measured value
Display out of limit value Visualize through 2 short beeps and visualize through red LED
display Two LCD displays can read measurement values even in difficult instrument positions (such as overhead)
USB port 2.0 compatible, used for connecting to PC
data transmission Single reading, average value, group separator
Allowable ambient temperature range during operation 0 . ... +40 °C (32 ... +104 °F)
Weight (including battery) MP0R: 137 g (4.8 oz)
MP0R-FP: 184 g (6.5 oz)
Dimensions (width x depth x height) Width: 64 millimeters (2.5 inches); Depth: 28 millimeters (1.1 inches); Height: 85 millimeters (3.35 inches)
power supply battery LR6,AA,1.5 V


Test function

Split program size Each block can be adjusted between 2 to 20 single readings
tolerance range Adjustable, depending on the selected measurement mode
compensation value In standard mode, adjustable offset values can be automatically subtracted from the measured values. Therefore, for example, in the case where the intermediate coating is known, the thickness of the top coating can be obtained.
unit of measurement Optional μ m or mil
Continuous display mode Measure in 'continuous display mode' to continuously sample surfaces, such as during the manufacturing of tanks and containers.
standardization Adapt to the base material and sample shape
calibration Factory calibration
Each individual instrument has been calibrated at several reference points in the factory, and extra care should be taken to ensure the highest possible accuracy.
Calibration (adjustment)
Use calibration foil to adapt to the shape and thickness values of the substrate and sample