Welcome Customer !

Membership

Help

Shanghai Neway Electronic Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Neway Electronic Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    Room E/F, 5th Floor, No. 1 Lane 1006 Jinshajiang Road, Putuo District, Shanghai

Contact Now

Fine grained soil three-axis nuclear magnetic microstructure analyzer

NegotiableUpdate on 07/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Fine grained soil triaxial nuclear magnetic microstructure analyzer (such as MacroMR12-150V-I) is a high-end equipment designed specifically for complex geotechnical engineering research. This device innovatively combines a vertical permanent magnet with a soil triaxial compression system, suitable for rock and soil samples with diameters ranging from 25 to 100mm; #160;. Not only does it have basic T1/T2 relaxation spectrum measurement and proton density weighted imaging functions, but the core breakthrough lies in the realization of in-situ joint measurement under multi field coupling conditions. While achieving multi field coupling such as temperature field, pressure field, chemical field, and seepage field, it is organically combined with traditional mechanical measurement methods such as soil triaxial.

Product Details


In the fields of soil science, agricultural engineering, and geotechnical disaster prevention and control,Fine grained soil three-axis nuclear magnetic microstructure analyzerIt is becoming an indispensable frontier tool for studying the microscopic characteristics of soil. Its core technology, low field nuclear magnetic resonance technology, with its unique advantages of non-destructive, accurate, and dynamic, is profoundly changing the research paradigm of traditional soil physical properties.

细粒土三轴核磁微观结构分析仪

1、 Application background of low field nuclear magnetic resonance technology in soil research

Traditional soil testing methods, such as dry drying, tensiometer, or centrifugation, can provide basic moisture data, but they generally have limitations such as time-consuming processes, damage to the original structure of the sample, and difficulty in distinguishing different forms of moisture (such as bound water, capillary water, free water). With the deepening of research on soil hydrological processes and engineering performance, researchers urgently need a technology that can detect soil moisture and pore structure in situ, continuously, and finely. The introduction of low field nuclear magnetic resonance technology has precisely filled this gap, achieving a leap from macroscopic measurement to microscopic insight, and providing new theoretical and technical support for soil degradation mechanisms, precision agricultural irrigation, and geological hazard prediction.

2、 Principles and core advantages of low field nuclear magnetic resonance technology

The physical basis of low field nuclear magnetic resonance technology originates from the relaxation characteristics of atomic nuclei in a magnetic field. Hydrogen protons in soil (mainly present in water) are magnetized in a low-intensity permanent magnetic field. When a specific frequency of radio frequency pulse is applied, hydrogen protons resonate and absorb energy; After the pulse stops, hydrogen protons release energy and return to equilibrium, a process called "relaxation". The relaxation time (T2) detected by the instrument contains rich information: the length of the relaxation time directly reflects the degree of binding of water. The more tightly water molecules are bound by soil particles (such as strongly bound water on the surface of clay particles), the shorter the relaxation time; And free water with high degrees of freedom stored in large pores has a longer relaxation time.

Compared with traditional methods, this technology has significant advantages:

Non destructive and fast: No need to damage the sample, continuous dynamic measurement of the same sample can be carried out, greatly improving experimental efficiency and data coherence.

Accurately distinguish water states: It can quantitatively distinguish bound water, capillary water, and free water, which is incomparable to traditional methods that can only determine total water content.

Multidimensional information acquisition: Relaxation spectra can not only reflect water distribution, but also invert information such as soil pore size distribution and specific surface area, and simultaneously obtain multiple physical indicators in one measurement.

Integrating the above-mentioned technologiesFine grained soil three-axis nuclear magnetic microstructure analyzerMacroMR12-150V-I is a high-end equipment designed specifically for complex geotechnical engineering research. This device innovatively combines a vertical permanent magnet with a soil triaxial compression system, suitable for rock and soil samples with diameters ranging from 25 to 100mm. Not only does it have basic T1/T2 relaxation spectrum measurement and proton density weighted imaging functions, but the core breakthrough lies in the realization of in-situ joint measurement under multi field coupling conditions. While achieving multi field coupling such as temperature field, pressure field, chemical field, seepage field, etc., it is organically combined with traditional force measurement methods such as soil triaxial testing for joint measurement.

细粒土三轴核磁微观结构分析仪

Basic Parameters


Product model: MacroMR12-150V-I

Magnetic field strength: 0.30T ± 0.03T

Magnet uniformity: ≤ 50ppm

Magnet shape: vertically placed

Injection method: longitudinal

Product Features

1. Ultra wide magnetic cavity, easy injection without pressure:

Vertically placed magnet, specially developed for experimental scenarios considering gravity, suitable for core samples with diameters ranging from 25 to 100mm.

2. High precision constant probe for you, first enter the gradient system:

The data collection is stable and reliable, achieving better imaging effects, as well as constant gradient layer detection during dynamic experimental processes.

3. Wide range of attachment extensions:

Multi specification core clamps and sample chambers are used to simulate various real environments (temperature, pressure, fluid, gas, etc.), especially coupled with soil triaxial clamps, to achieve the joint measurement of low field nuclear magnetic resonance and traditional mechanics.

Product features

T1/T2 relaxation spectrum determination, T1/T2/proton density weighted image

Application of temperature, pressure, and fluid field (requires attachment support)

Product Application

1. Moisture content

·Moisture content determination

·Determination of moisture content at different levels

·Research on Soil Freeze Thaw Mechanism

·Determination of unfrozen water content

·Characterization of pore structure

2. Water distribution and seepage mechanism

·Dynamic migration process of water

·Types and distribution characteristics of pore water

·Soil water freeze-thaw phase transition and distribution characterization

·Evaluation of Soft Soil Solidification, Solid Waste, and Grouting Improvement

·Temperature/pressure/fluid multi field coupling experiment

·Analysis of Infiltration and Absorption Process and Characteristics

·Research on the Formation and Decomposition Mechanism of Frozen Soil Hydrates

3. Soil triaxial

·Porosity and pore size distribution detection

·Static/dynamic triaxial compression analysis

·Evaluation of freeze-thaw compression damage

·Analysis of Consolidation Drainage Shear Experiment

·Experimental evaluation of thermal solidification of saturated clay

·Analysis of three-axis custom waveform compression

·Research on the Mechanism of Soil Vibration, Liquefaction, and Water Transport

·Evaluation of three-axis melting, settling and compression coefficient of frozen soil

Use Cases:

细粒土三轴核磁微观结构分析仪

Fine grained soil three-axis nuclear magnetic microstructure analyzerWith the unique non-destructive, dynamic, and multi field coupling detection capabilities of low field nuclear magnetic resonance technology, the research paradigm of soil microstructure is being redefined, providing unprecedented accurate data support for the fields of geotechnical mechanics and geological environmental protection.

Pre sales service: in-depth experience, precise selection

Neway has a professional customer experience center, welcoming customers to visit the site, have zero distance contact and operate the equipment, and intuitively feel its performance and usability. Through on-site experience and professional explanations from senior consultants, we help clients accurately evaluate whether the equipment meets their application needs.

After sales support: fast response, professional guarantee

Quick response mechanism: We promise to respond within 4 hours and provide a solution within 8 hours. If remote solutions are not possible, engineers will arrive within 24 hours in provincial capitals and 72 hours in remote areas, including holidays. Ensure that users receive timely and effective handling when encountering problems, minimizing the impact of equipment downtime.

Professional team configuration: We have a highly educated service team of nearly 20 people, with master's degrees accounting for over 60%. We have a strong technical foundation and customized service capabilities to ensure that complex problems are solved professionally and efficiently.

Multiple communication channels: support telephone QQ、 WeChat and other various methods provide convenient and flexible communication, and can respond to customer needs at any time.

User training empowerment: Neway has established a normalized training system. In addition to holding regular application training courses, it also provides flexible online and offline daily training. Users can obtain software and hardware training videos anytime and anywhere through "Newmart Analysis", "Newmart Service" WeChat official account and "Nuclear Magnetic Research Energy Station" applet, so as to continuously improve operating skills and application level and maximize the value of equipment.

Proactive service culture: Adhering to the concept of "achieving customer success and taking responsibility", engineers actively follow up, proactively solve problems, help customers reduce unnecessary repair processes, and save time and energy. And continuously optimize service processes based on customer feedback, growing together with customers.

Device QR code identification: Each device is equipped with a QR code identification, and customers can quickly obtain online support entry by scanning the code, greatly improving service response efficiency and convenience.

Full dimensional service centers cover the whole country: Neway has 7 full dimensional service centers located in Shanghai, Suzhou, Chengdu, Guangzhou, Zhengzhou, Beijing, and Taiyuan, covering all regions of China, ensuring that service resources can quickly reach customers across the country.