The FY3100 pen type electromagnetic ultrasonic thickness gauge is suitable for measuring the thickness of high-temperature pipelines and pressure vessels in chemical and special inspection industries. No need for coupling agent, high temperature resistance below 800 degrees, no calibration required!Welcome to call for further inquiries:Price discounts. Long term spot goods!!
highlight features
u Rich types of probes
Optional small diameter probe, high temperature probe, normal temperature probeBScanning probe, split small tube diameter probe, split large lift probe, split high temperature probe90Roller probe, customized probe.
u Ergonomic optimization design
Compact structure, ultra small volume, easy to carry. Comfortable grip, strong magnetic attraction, and improved fatigue conditions.
u wireless connection
Can connect tablets and phones, equipped with associationsAPPachievableWIFIConnect, synchronously display measurement waveforms, and can also work offline through the instrumentLEDDisplay thickness and adjust the instrument. Optional at the same timeRS485Communication box.
u Accurate thickness measurement, no coupling required, can penetrate coatings
Professional algorithm program support, measurement results * *. No need for coupling agents, no need to polish the surface of the workpiece, allowing for paint, coating, and uneven unevenness on the tested surface.
u Suitable for high temperature environments
Suitable for measuring thickness in high-temperature pipelines, boilers, and pressure vessels, without the need for cooling the measured object to improve work efficiency. Widely used in fields such as petroleum, chemical, metallurgy, shipbuilding, aviation, and aerospace.
u Built in multiple materials for sound speed
The instrument pre stores multiple material sound velocities and can dynamically add and delete material sound velocities. Sound velocity calibration adds temperature compensation function to improve measurement accuracy.
u Low power design with reliable performance
Built in lithium battery, low power consumption of nodes, capable of continuous operation4-5hour
Instrument parameters:
|
Product Parameters |
|
|
Detectable workpiece material Conductor materials such as carbon steel, cast steel, alloy steel, stainless steel, copper, aluminum, titanium, etc |
Receiving gain ≤100 dB |
|
measurement range 1~ 250.0mm(The measurement range depends on the material) |
*High resolution OELDMenu display 0.01mm |
|
High temperature probe ≤800℃The4MHz, mainly used for detecting ferromagnetic fine-grained materials, such as low carbon steel |
Room temperature probe ≤150℃The4MHz, mainly used for detecting fine-grained materials such as low carbon steel, aluminum, etc |
|
Measurement equipment error range workpiece thickness≤10mmTime, error±0.05mm; Thickness>10mmWhen, error±(0.01+H/200)mm(HFor the thickness value of the workpiece) |
High temperature probe operating temperature range Low carbon steel (or other ferromagnetic steel):-150 ~ +800℃, Austenitic stainless steel (or other non ferromagnetic materials):-150 ~ +150℃ |
|
Can detect the small diameter (curvature) of the workpiece 8 mm |
Waveform display Positive half wave, negative half wave, full wave, radio frequency wave, envelope wave |
|
Probe * large tilt angle ±25° |
power supply Built in lithium battery, working time4- 5hour |
|
Probe excitation method permanent magnet |
Sound wave type Shear wave (transverse wave) |
|
host weight 250g(Equipped with room temperature probe) |
Host storage temperature range 0 ~ +40℃ |
|
High temperature compensation Equipped with high-temperature sound speed automatic compensation function |
Range of sound speed adjustment for sound waves 1000~9999m/s |
|
Overall dimensions of the host long170mm×wide40mm×thick33mm |
Normal operating temperature range of the host -10 ~+50℃ |
Standard configuration:
|
serial number |
name |
quantity |
Remarks |
serial number |
name |
quantity |
Remarks |
|
1 |
host |
1 |
standard configuration |
6 |
AndroidAPPsoftware |
1 |
standard configuration |
|
2 |
Room temperature probe |
1 |
standard configuration |
7 |
charging cable |
1 |
standard configuration |
|
3 |
10mmCarbon steel calibration test block |
1 |
standard configuration |
8 |
Instrument box |
1 |
standard configuration |
|
4 |
10mmStainless steel calibration test block |
1 |
standard configuration |
9 |
Instruction manual, certificate of conformity, warranty card |
1 |
standard configuration |
|
5 |
5Vpower adapter |
1 |
standard configuration |
|
|
|
|
Optional accessories:
|
serial number |
name |
quantity |
Remarks |
serial number |
name |
quantity |
Remarks |
|
1 |
Integrated ambient temperature probe |
1 |
(optional) |
6 |
Split type high-temperature probe |
1 |
(optional) |
|
2 |
Integrated high-temperature probe |
1 |
(optional) |
7 |
split-body90° pulley probe |
1 |
(optional) |
|
3 |
integratedBScanning probe |
1 |
(optional) |
8 |
Customized probe |
1 |
(optional) |
|
4 |
Split type large lifting probe |
1 |
(optional) |
9 |
RS485Real time communication device |
1 |
(optional) |
|
5 |
Split type small tube diameter probe |
1 |
(optional) |
10 |
Mobile phone or tablet |
1 |
(optional) |