-
E-mail
2316332107@qq.com
-
Phone
15965217685
-
Address
Dezhou Technology Development Zone, Shandong Province
Shandong Pengkun Air Conditioning Equipment Co., Ltd
2316332107@qq.com
15965217685
Dezhou Technology Development Zone, Shandong Province
Fan coil units are mainly composed of centrifugal fans, coil heat exchangers, etc., and are the end devices of central air conditioning systems. They are widely used in air conditioning fields of multi room or large space industrial and civil buildings such as hotels, restaurants, factories, hospitals, exhibition halls, shopping malls, and office buildings to meet the requirements of cooling, dehumidification, heating, etc., and create a fresh, peaceful, and spring like working and living environment for people all year round. Our company's fan coil units have undergone design optimization, resulting in significantly improved coil performance. The coil units are divided into two types: high-efficiency and standard; The standard fan coil unit can meet the various parameters required by the national standard, while the performance parameters of the high-efficiency fan coil unit are better than the national standard requirements20%above. FP-LAThe vertical concealed fan coil unit model has an ultra-thin body and does not occupy effective space. It can be placed under windows, in walls, or in grooves with decorative panels. It has two forms of upper air outlet and front air outlet, and is suitable for places such as conference rooms, halls, or sports halls. DC brushless fan coil unit Using a brushless DC motor to achieve diversified control of high, medium, and low speed regulation, as well as stepless speed regulation. 1The working speed range is wide, which can meet the speed requirements of various air volume modes. 2As the motor speed decreases, the air volume also changes, which reduces energy consumption and achieves energy-saving effects. Waterway control system Two or three way open/The closed type waterway control system includes electric actuators, valves, and related components. The control system is directly installed by the factory on the coil unit with an extended water tray, and achieves automatic indoor temperature adjustment by controlling the opening and closing of the cold or hot water system. 1Easy to install, only need to connect the water pipe and power supply on site to put it into use. 2Compact design, fully utilizing the extended water tray space, without the need to change the size of the unit. FP-LACharacteristics of vertical concealed fan coil unit 1Safe and reliable, with a long lifespan. Each coil heat exchanger undergoes pressure leak detection; Inlet and outlet connection (the water collection head adopts forged brass structure, reliable and durable); The condensate tray is treated with spray coating, which does not rust, and all materials are made of imitation active type; The electric motor adopts ultra-low noise rolling bearings, which do not require users to refuel or repair, and have a service life of up to35000Hour; The slender shaft diameter of the electric motor has undergone special treatment and is rust free. 2High efficiency, energy group The fan coil unit adopts seamless copper tube series with funny double flanged aluminum ribs tightly integrated, with high heat transfer efficiency and abundant cold (heat) capacity. The standard coil unit can meet the performance requirements of the national standard, and the high-efficiency coil unit has reached the international leading level. 3High air volume and low noise The fan coil unit adopts an ultra wide angle volute shell and steel plate multi blade centrifugal impeller. The impeller and motor can be matched with multiple priority options to meet the needs of various specifications of the fan coil unit. 4Flexible selection Considering the unique characteristics of installation sites and site limitations, our company provides water trays of different lengths for customers to choose from. 1Standard water tray - reduces the required installation position, especially suitable for places with limited installation space. 2Extend the water tray - it can better catch valve leaks and condensed water. Installation and usage instructions for fan coil units 1The fan coil unit should be installed on a horizontal surface, kept vertical, and not tilted; When installing a horizontal unit, the four lifting points must be kept level to prevent one end of the condensate pipe from rising and causing condensate overflow. 2Valves should be installed on the inlet and outlet water pipes for easy adjustment and maintenance, and attention must be paid to the cleanliness and insulation of the inlet and outlet water pipes. The plastic pipes for condensate water should not be biased or have dead bends to ensure smooth condensate water flow during use. 3The three speed control switch of the unit should be started from high gear when turned on, and then other gears should be selected. When multiple machines are shared, single machine control is necessary. 4Unit power supply: single-phase220v±10%,50HzThe AC motor casing should be equipped with a grounding wire. If there are difficulties in starting the unit, it is necessary to check whether the power supply is normal and whether the wind turbine is in contact with the fan volute. When installing the unit, attention must be paid to not damaging the casing, heat exchanger fins, and fan to avoid affecting the appearance and performance. 5The temperature of the cooling water supplied by the unit in summer shall not be lower than7℃, the temperature of heating water in winter shall not exceed80When using cold or hot water, it is necessary to consider the local water quality conditions for softening treatment. 6The maximum allowable pressure for the unit1.6MPa. 7The filter should be regularly cleaned to maintain cleanliness and ensure good heat transfer. 8After connecting the power supply, the fan should be started first to observe whether its rotation direction is correct. 9If the unit is installed in a dark place, it should be equipped with maintenance doors for year-round maintenance. 10The power supply should be cut off during maintenance of the unit. 11For the installation and use of cassette fan coil units, please refer to the accompanying manual. 12With the continuous improvement of our factory's technical level, we have the right to change the product specifications. If the performance parameters of the unit are changed, the random technical documents shall prevail without further notice.