- Phone
-
Address
101, Private No.1 Comprehensive Building, Intersection of Mingzhu Road and Taiping Road, Jianhu County, Jiangsu Province
Yancheng Tianyue Instrument Co., Ltd
101, Private No.1 Comprehensive Building, Intersection of Mingzhu Road and Taiping Road, Jianhu County, Jiangsu Province
oneProduct Introduction
FCC-30S explosion-proof dual channel dust sampler is a new type of dust sampler specifically designed for fixed-point sampling of occupational health dust hazards and microbial sampling in public places.
The sampler has the characteristics of constant current, explosion-proof, portable, long battery life, and strong load capacity. The load capacity can reach 20Kpa, and the battery life can reach 8 hours,
It can complete the sampling of both full dust and exhaled dust in one go. The 5-inch touch screen is easy to operate and use normally.
FCC-30S explosion-proof dual channel dust sampler is a digital constant current dual channel dust sampler, consisting of a high-performance air pump, automatic time control circuit, flow regulation circuit
It is composed of an automatic feedback constant current circuit and is also equipped with various dust pre collectors. This type of pre collector can capture respiratory and non respiratory dust that poses a risk to human health
Separation can collect both respiratory and non respiratory dust samples at once, and its separation efficiency meets the "BMRC" curve standard. It is a reliable and practical dust front-end separation device.
twoApplication Fields
JJG520-2005 Verification Regulations for Dust Samplers
GBZ/T 192-2007 Determination of Dust in Workplace Air
threeTechnical parameters
1.Flow range:dual-path(3~30)L/minResolution:0.01L/min
2.High definition color touch screen, interface size:108mm*66mm
2.Constant current mode: Constant current and constant voltage (precise closed-loop control of flow rate not affected by voltage fluctuations and air resistance changes)
3.Flow calibration: an open backend calibration system where users can perform self calibration on the instrument.
4.Volume calculation: Automatic calculation of working condition volume and standard condition volume
5.Flow error:<±2.5%FS
6.Color touch screen:provideLoad resistance, real-timeTraffic, running timestandard volume, battery levelDate and time, pressure and temperatureWaiting for various information
7.provideLoad inlet resistance test, test range:40kpa-40kpa
8.The instrument comes with a lock screen function to prevent accidental operation from affecting the sampling process
9.The instrument is equipped with power-off protection function, and continues the previous sampling task after power on
10.Data storage: storable200Group sampling data, data can be deleted, queried and supportedUDisk export
11.Traffic stability: ≤5%
12.Traffic repeatability: ≤2%
13.Timing error: ≤±0.1%
14.Timing range:1min~99h59min
15.Operating Temperature-10~50℃
16.Relative humidity: ≤95%RH
17.battery life:>8hour@20L/min
15.Load capacity: ≥30Kpa
16.Timer mode: timed sampling, cyclic sampling, intermittent sampling, delayed sampling
17.Operating noise: <70dB(A)
18.Atmospheric pressure display: Yes; Temperature: Yes
19.Sampling range:dual-pathTotal dust and respiratory dust
20. Instrument weight: 3.2kg
21. Instrument size: 193 * 162 * 132mm
three.Configuration List
name |
quantity |
host |
a |
Instrument box |
a |
tripod |
a |
Total dust sampling head |
twoonly |
Dust sampling head |
twoonly |
Filter membrane clamp |
Five of them |
Impact film |
Five of them |
Impact film box |
Five of them |
silicone oil |
a bottle |
tweezers |
a |
charger |
a |
40mm polypropylene dust detection filter membrane |
a box |
Qualified warranty card for instruction manual |
a copy |