FC enzyme-linked immunosorbent assay (ELISA) analyzer official quotation/official channel FC inherits 30 years of experience in ELISA analyzer manufacturing, with a large screen color LCD display and built-in powerful functional software, which can meet the experimental needs with strict temperature detection requirements
FC ELISA reader official quotation/official channel:
*Point: Our after-sales service is very good, and the warranty period is one year.
There are many similar products from other brands that only come with a six-month warranty. Not only that, our enzyme-linked immunosorbent assay (ELISA) reader comes with tax and shipping included, and can be delivered to your doorstep————————————————————————————————————————————
Secondly, our company has after-sales service centers in major provinces and cities across the country, and our engineers are on business trips every day of the year,
Personally visit and inspect the situation. (Considerate enough, sincere enough, just one phone call from you is missing)
FC ELISA reader regular quotation/introduction of product advantages through regular channels:
Measurement mode:
1. Single wavelength detection: measuring absorbance at one wavelength (also known as the key method)
2. Dual wavelength detection: Measure absorbance using two wavelengths; *Subtract the second measurement result from the second measurement result.
3. Dual time detection: Measure the absorbance of the plate at two different time points, and subtract the result of * measurements from the result of the second measurement.
4. Dynamics testing: Measure the rate of change in absorbance.
5. Multi wavelength detection: The absorbance value of each column is detected using a different wavelength, which is only available in the basic enzyme-linked immunosorbent assay program;
6. Computer control: The instrument is controlled by an external computer and is only available in the basic enzyme-linked immunosorbent assay program.
The Chinese computer software is based on the Windows interface and can input and query experimental results, print comprehensive sample reports, create quality control charts, set enzyme immunoassay parameters, perform qualitative and quantitative measurements, design 96 well plate diagrams, and also meet the needs of internal LAN networking.

FC enzyme-linked immunosorbent assay analyzer regular quotation/introduction of product characteristics through regular channels;
The proven reliability comes from the built-in self diagnostic program. During the start-up phase of the instrument, the built-in self diagnostic program will assess various factors including the position of the microplate, the stability of the optical components (light source, filter), etc
Conduct comprehensive performance testing on various aspects.
FC comes standard with an oscillator and an optional incubator, with a maximum temperature of 50 degrees Celsius, which can meet the experimental requirements for strict temperature detection.
Powerful internal software with multiple interface languages available, including Chinese. Functions include: setting the layout of microplates (including blanks, standards, test samples, quality control samples, etc.), displaying test results, and performing data processing (including kinetic analysis, data preprocessing, curve fitting, etc.)
Integration, data classification, quality control, etc. In addition, FC can also use the powerful SkanIt software for instrument control and data result processing.
FC enzyme-linked immunosorbent assay analyzer regular quotation/regular channel fault introduction:
Fault 1: No response after startup
Reason: The power supply is not connected. Check if the power cord is properly connected and if the fuse is blown.
Fault 2: The original absorbance is mostly negative
Reason: Check if the absorbance value of the blank hole is too high. The original absorbance value printed by the enzyme-linked immunosorbent assay (ELISA) is obtained by subtracting the blank. If the blank is too high, negative values may appear.
Fault 3: When using the quantitative function of the enzyme-linked immunosorbent assay (ELISA) reader, the curve exhibits abnormal morphology
Reason: It is possible that the customer used a linear/logarithmic curve pattern and also used a standard substance with a concentration of 0, which caused the machine to be unable to take the logarithm of 0, resulting in an abnormal curve shape.
Fault 4: During quantitative measurement, the concentration value in the printed report appears as * * * *, indicating that it exceeds the curve range
Reason: Excessive standard absorbance may cause the curve to shift upwards, making it impossible to print many samples with low absorbance values on the report. To solve this problem, dilute the standard sample to shift the curve downwards.
Fault 4: Enzyme linked immunosorbent assay (ELISA) reader is usually used in conjunction with a washing machine
Reason: The purpose of washing with an enzyme-linked immunosorbent assay (ELISA) washing machine is to separate the antigen antibody complexes formed on the solid-phase carrier from other excess free reactants in the liquid. Wash to remove unbound antigens and impurities, and after washing, only specific antibodies remain on the solid-phase carrier. Other immunoglobulins and impurities in serum are washed away during the washing process because they cannot bind to solid-phase antigens.
Manufacturer Services
Professional engineering team provides free guidance on installation and debugging.
The whole machine comes with a one-year warranty and free maintenance during the warranty period. (The warranty period for some products has changed, please consult the selection specialist for details.)
After receiving the feedback notification, respond within 10 minutes and provide repair services within 48 hours.