FAGOR grid reading head | CP/CT/CX/LABC50/GAP50-AClosed grating ruler reading headUsed for incremental linear grating ruler systems, commonly found in industrial automation scenarios such as CNC machine tools and measuring equipment. Provide specifications, models, prices, fault detection and maintenance, installation and debugging, accessory supply, and technical solutions for CP/CT/CX/LABC50/GAP50-A grid grating rulers.
FAGOR grid reading head | CP/CT/CX/LABC50/GAP50-ATechnical parameters of closed grating ruler reading head:

FAGOR CP Reading HeadIt is a key component in its grating ruler system, mainly used for high-precision displacement measurement. The following are technical parameters:
Model ExampleCP-225, COP-10A, etc
working voltageUsually:DC 5V or 24V(Some models support the range of 2.5V-110V)
Output signal type:Differential TTL (RS-422 compatible)The common signal cycle is20 μ m or 4 μ m
resolution: reachable0.001μm(1nm)Typically, it is0.001mm(1μm)
measure length: Support0–60mScope
cable length:150 meters(Depending on signal type and environment)
Protection levelOpen type models are usuallyIP50 or IP65(Need to confirm with specific model)
Installation methodNon contact, with LED installation indicator, supporting side fixationwait
power issueVoltage instability, loose cables (check if it is within the rated range of DC 5V/24V)
signal interferenceShielded cables are required to stay away from strong electromagnetic fields
Pollution impactDust and oil stains covering the optical window can cause signal loss
Installation deviationAngle errors or mechanical vibrations can affect accuracy
Typical fault phenomena:
Unable to return to the reference point
Unidirectional counting
Display 'EEEEEEEE' (reference point not triggered or out of range)
Signal cable model: EC-3A-C5、EC-3B-C9、EC-6P-0 等
compatible system: SupportFANUC、SIEMENS、MITSUBISHI、PANASONICWaiting for the CNC system
communication protocolSSI, TTL, HTL, etc. (depending on the specific model)

FAGOR CT series reading headTechnical parameters:
typeGrating ruler reading head (non-contact reflective type)
communication protocol: Supported by TongSSIOrBISS-C(depending on the sub model)
resolution: Commonly seen as0.01 μm / 0.05 μm(Optional)
power supply voltage:5 V ±10%The no-load current is approximately250 mA
measurement rangeDepending on the matching grating ruler, the typical one is70 mm to 3020 mm(One step every 50 mm)
speed:480 m/min
Protection level:IP40(Only for the reading head body)
Operating Temperature:0 ° C to 45 ° C(Suitable for 0.05 μ m resolution configuration)
Installation gapSuggestion:1.0 ± 0.05 mm(Between the reading head and the steel tape ruler)
cable length: Matching1 meter or 3 meters, with plugs (such as EC-3A-C1, EC-3A-C5, etc.)
Compatible Systems: CompatibleSiemens (such as 840D), Mitsubishi, Panasonic, YaskawaWaiting for the CNC system

FAGOR CX series reading headMainly used forIncremental Linear Grating Ruler SystemCommonly used in industrial automation scenarios such as CNC machine tools and measuring equipment. The following are technical parameters:
Signal type:TTL differential square waveOr1Vpp sine signal(depending on the specific model)
resolution:Up to 1 μ m(Some models support higher precision)
precision:±5μm
Output signal cycle:20μmOr4μm(Depending on the model)
cable length:20m to 150m(Depending on signal type and configuration)
Installation methodFixed at both ends, some models can choose the middle suspension block attachment
Applicable grating ruler seriesCX series reading heads are usually paired withC-series grating rulerUse
compatible system: Support andFAGOR、FANUC、 Mitsubishi, Siemens, PanasonicWaiting for CNC system communication
CX-1025
CX-1345
CX-2245
CX-2645
CX-625
CX-725
CX-825
CX-925
These models are mostly used forMedium range linear displacement measurementThe measurement range usually covers100mm to 1000mmDon't wait.
CX reading headExcluding signal linesCorresponding cables (such as EC-3A-C5, EC-1A-C1, etc.) are required.
If neededAbsoluteFunction, should be selectedModels outside the CX series(such as G2A, G2AP, etc.), CX series is generallyincremental .

FAGOR reading headModel LABC50The technical parameters of models (such as L2ABC50, LX/LP series) are as follows:
Model analysis:
The reading head model usually follows the format of "series+function+resolution+cable length+interface". For example:
L2ABC50In the middle, "L2" represents the reading head series, and "C50" often refers to50mm grid spacingOr50 nm resolution.
LABC50 is likely to beL seriesA variant of (incremental/ABS linear grating), where "C50" most likely corresponds to50 nm resolutionOr50mm reference point interval.
Technical parameters (based on L2ABC50 and L series data):
resolution:50 nm(Commonly seen in high-precision L series)
Measurement type:incremental(such as the L series) orABS type(For LA series, please confirm the suffix)
output signal:TTL differentialOrSine wave (1 Vpp)
power supply voltage:5 V ±10%(No load current<250 mA)
speed:180 m/min
accuracy class:±3 μm/m 至 ±5 μm/m
Installation methodNon contact (open) with LED installation indicator
cable length: Commonly seen as1 m or 3 m(As in L2ABC50-3D9D, "3" represents 3 meters)
Fag
L2ABC50TheLXABC50Wait. Suggest checking the actual product label.

FAGOR GAP50-A Reading HeadTechnical parameters:
Model identificationGAP50-A belongs to the FAGOR grating ruler reading head series, where the suffix "- A" usually indicates the reading headEquipped with air inlet(Used for cleaning the grating surface to prevent dust pollution).
resolutionFAGOR GAP series grating ruler supports0.05 μ m resolutionSuitable for high-precision measurement scenarios.
Application Type: Suitable forLinear grating ruler system, commonly used in industrial automation scenarios such as CNC machine tools and measuring equipment.
compatibilityGAP50-A has system compatibility with other C-series (such as CT, CX, CP) and MK series (such as MKX, MKT) reading heads of FAGOR.
signal interfaceUsually used in conjunction with EC series signal feedback cables (such as EC-1A-C1, EC-3A-C5, etc.), it supports differential signal output and has strong anti-interference ability.
Air intake functionThe reading head with the "- A" model can be filled with clean compressed air during operation to keep the grating lines clean and improve long-term stability.
Installation and MaintenanceIt is recommended to install a protective cover and clean it regularly to avoid dust and oil stains affecting the accuracy of optical readings.
voltage rangeFAGOR grating ruler system generally supports2.5V–5VThe working voltage range needs to be confirmed in conjunction with the supporting controller.