Welcome Customer !

Membership

Help

Shanghai Instrument Marketing Center
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Instrument Marketing Center

  • E-mail

  • Phone

  • Address

    190 Guangzhong West Road, Shanghai

Contact Now

Explosion proof pressure controller/-0.1-0.16MPa

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

0850380 pressure switch, D502/7D explosion-proof pressure controller/-0.1-0.16MPa, Shanghai Far East Instrument Factory controller adopts bellows type sensor, which can be used for neutral gases such as air, gas, water vapor, and liquid media such as water, refrigerant, oil, etc. The setting value of the controller is adjustable. Adjustment range -0.1... 2.5 Mpa.

Product Details

0850380 pressure switch,D502/7DExplosion proof pressure controller/-0.1-0.16MPa, Shanghai Far East InstrumentWatch FactoryProduct Introduction:

The controller adopts a bellows type sensor, which can be used for neutral gases such as air, gas, and water vapor, as well as liquid media such as water, refrigerant, and oil. The setting value of the controller is adjustable. Adjustment range -0.1... 2.5 Mpa.

0850380 pressure switch,D502/7DExplosion proof pressure controller/-0.1-0.16MPa, Shanghai Far East InstrumentWatch FactoryParameters and specifications:

Working viscosity

<1×10-3m2/s

Switching element

micro switch

Explosion-proof rating

ExdeCT5Certificate of conformity number GYB00108X

Shell protection level

IP54(Compliant with DIN40050, equivalent to IP54 in GB4208)

ambient temperature

-5~40℃

medium temperature

0~120℃

Installation location

Pull interface vertically downwards

vibration resistance

Max:20m/s2

repeatability error

≤1%

contact capacity

DC 250V 0.25A(Resistive) 60 Wmax

AC 250V 5A(Resistive 1250VAmax

0850380 pressure switch,specification

Switching difference is not adjustable

Set value adjustment

scope

MPa

Switching difference not greater than

Maximum allowable pressure*

MPa

Switch switch

Change times

times

Pressure sensor material

Interface
internal thread

weight
kg

Outline dimension drawing number

Order catalog number

Set value range

Lower limit

MPa

Set value range

upper limit

MPa

shell

bellows

普通型

Explosion-proof type

普通型

Explosion-proof type

-0.1??0

-0.1??0.1

-0.1??0.16

-0.1??0.25

0.006

0.007

0.008

0.009

0.007

0.008

0.009

0.012

1

20

brass

Stainless steel 00Gr17Ni14M02 (316L)

G1/4

1.0

01

04

0810100

0810200

0810300

0810400

0850180

0850280

0850380

0850480

0??0.1

0??0.16

0.01??0.25

0.007

0.008

0.009

0.008

0.009

0.01

1

1.0

01

04

0811100

0811200

0811300

0851180

0851280

0851380

0.02??0.4

0.03??0.6

0.03??1

0.03

0.03

0.03

0.03

0.035

0.04

2

0.85

02

05

0811400

0811500

0811600

0851480

0851580

0851680

0.05??1.6

0.05??2.5

0.07

0.07

0.08

0.09

2

0.9

03

06

0811700

0811800

0851780

0851880

Switching difference adjustable

Set value adjustment

scope
MPa

Switching differential adjustment range

Dayun
Xu Pressure
MPa

Switching frequency
times

Pressure sensor material

Interface
internal thread

weight
kg

Outline dimension drawing number

Order catalog number

Set value range

Lower limit

MPa

Set value range

upper limit

MPa

shell

bellows

普通型

Explosion-proof type

普通型

Explosion-proof type

-0.1??0

-0.1??0.1

-0.1??0.16

-0.1??0.25

0.018…0.08

0.019…0.1

0.02…0.2

0.022…0.25

0.019?0.08

0.021?0.1

0.022?0.2

0.024?0.25

1

20

brass

Stainless steel 00Gr17Ni14

M02(316L)

G1/4

1.05

01

04

0800100

0800200

0800300

0800400

0840180

0840280

0840380

0840480

0??0.1

0??0.16

0.01??0.25

0.015…0.08

0.018…0.1

0.02…0.2

0.016?0.08

0.025?0.1

0.024?0.2

1

1.05

01

04

0801100

0801200

0801300

0841180

0841280

0841380

0.02??0.4

0.03??0.6

0.03??1

0.08…0.25

0.08…0.5

0.09…0.8

0.08?0.25

0.09?0.5

0.1?0.8

2

0.9

02

05

0801400

0801500

0801600

0841480

0841580

0841680

0.05??1.6

0.05??2.5

0.17…1.2

0.18…2

0.19?1.2

0.2?2

5

0.95

03

06

0801700

0801800

0841780

0841880

Note:*)In practical work, even a brief peak pressure cannot exceed this value.