Explosion proof ozone analyzer, explosion-proof O3 detector tester

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Measurement principle: According to the Beer Lambert law, the dual path ultraviolet light absorption method has high measurement accuracy; $r $n light source system: long-life ultraviolet lamp tube (wavelength 253.7nm) $r $n light cell system: separated light cell technology, no leakage, high pressure resistance, $r $n resistant to high flow sampling gas impact; $r $n intelligent compensation: built-in light source automatic compensation function; $r $n automatic zero calibration: The equipment automatically calibrates once every 3 hours to ensure the stability of the zero point and the accuracy of the detected concentration. Data display: Devin 5.0-inch touch screen, easy for users to operate

Product Details

Measurement principle: According to the Beer Lambert law

Testing method: Dual path ultraviolet absorption method, with high measurement accuracy;

Light source system: Long life ultraviolet lamp tube (wavelength 253.7nm)

Light cell system: Separated light cell technology, leak free, high pressure resistance

Resistant to high flow sampling gas impact;

Intelligent compensation: built-in light source automatic compensation function;

Automatic zeroing: The equipment automatically zeros once every 3 hours to ensure the stability of the zero point and the accuracy of the detected concentration.

Data display: Devin 5.0-inch touch screen, easy for users to operate

Output function: 4-20mA current signal, RS485 communication

Detection principle: UV dual path absorption method, used for real-time detection of ozone generator outlet concentration or tail gas ozone concentration detection.

Measurement range: 0-300g/Nm3/0-200g/Nm3

Product features: Equipped with automatic zero correction function, dual path UV absorption principle, overseas long-life UV LED light source, can operate continuously, ensuring the stability of detection concentration.

Product brand: USIDEAL Process: ZL 2017 2 0109915.5

This ozone gas concentration analyzer has an automatic zero calibration function, which can also automatically calibrate and correct the zero point of the ozone analyzer when ozone is introduced to ensure the stability of the zero point. This ozone analyzer can operate continuously for 24 hours without stopping.

The UVOZ-3200C ozone gas analyzer is designed and manufactured based on Lambert Beer's law, the national environmental standard of the People's Republic of China "Determination of Ozone in Environmental Air - Ultraviolet Method", and the verification and calibration methods of the Ministry of Construction of the People's Republic of China "Ozone Generator for Water Treatment". By measuring the changes in light signal intensity before and after the absorption of ultraviolet light by ozone, the current ozone concentration value can be calculated. The equipment uses an advanced dual path ultraviolet light source system, which is equipped with an intelligent management system for the lamp tube. After turning on, the ultraviolet lamp tube can quickly reach the measurement state. It adopts foreign separated light cell technology and has the characteristics of no leakage, high pressure resistance, high flow sampling gas impact resistance, easy cleaning, convenient maintenance, simple operation, and low usage cost. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in environments such as pipelines and containers during operation. Widely used in industries such as pharmaceuticals, chemical, municipal, and sewage treatment to measure the export concentration and production of ozone generators.

The ozone analyzer is equipped with a touch screen operation interface, which displays the concentration of ozone gas in real time. It has pressure and temperature compensation and display, and can set automatic zero calibration time and manual zero calibration mode. The high concentration (g/Nm3) range is equipped with a flow input function, which can display the output of the ozone generator in real time. Equipped with two sets of relay signal outputs, users can freely choose between high and low alarm point signal output connections. The core components adopt a UV long-life light source system and use high transmittance quartz plates to ensure the stability of the zero point and prevent zero drift from affecting the accuracy of concentration detection. Based on the pressure resistant and impact resistant independent light cell structure designed using foreign light cell technology, the gas flow rate, pressure, and flow velocity remain unchanged during zero calibration operation to prevent the impact of airflow on zero calibration. Zero calibration operation can be completed without closing the ozone inlet, ensuring that the equipment can operate continuously 24 hours a day.

Application fields: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry, food and drinking water industry, space disinfection industry, swimming pool disinfection industry, essence synthesis industry and other industries using ozone generators.



2、 Technical parameters

Model: UVOZ-3200C

Measurement range: 0-300g/Nm3

Optional range: 0-200g/Nm3, 0-100g/Nm3, 0-50g/Nm3

Light source lifespan: approximately 15000-20000 hours;

Sampling method: positive pressure sampling, negative pressure sampling (optional);

Display interface: 5-inch or 7-inch touch screen operation interface;

Content interface: Ozone concentration, temperature, pressure;

Auxiliary functions: temperature compensation, pressure compensation;

Display units: g/Nm3, mg/NL,% WT optional;

Display resolution: 0.01g/m3;

Accuracy: ± 3%

Gas flow rate: 1.0L ± 0.2L/min;

Input pressure:<0.1MPa;

Concentration error: maximum 0.5% FS;

Linear error: maximum 0.5% FS;

Zero drift:<± 0.3% FS;

Response time: Signal 0.03 seconds, display 0.3 seconds;

Environmental temperature: -20~50 ℃;

Pipeline interface method: quick twist (stainless steel);

Gas inlet and outlet pipe diameter: inner diameter 4mm, outer diameter 6mm PTFE pipe;

Communication method: RS-485;

Output mode: Differential 4-20mA (active linear);

Power supply: AC 110-220V;

Dimensions: 350mm (height) x 270mm (width) x 130mm (depth);

注: 1mg/L=1g/m3=467PPM;

Free warranty: 24 months (for the host sensor);

Note: Standard configuration (built-in): flowmeter, ozone exhaust catalyst, intake filter.


DSA.jpg

This ozone gas analyzer is mainly used for measuring ozone concentration inside the ozone generator pipeline, and can continuously detect the ozone concentration in the outlet pipeline of the ozone generator online. It is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in environments such as pipelines and containers during operation. Widely used in industries such as pharmaceuticals, chemical, municipal, and sewage treatment to measure the export concentration and production of ozone generators.

This ozone gas analyzer is designed and manufactured based on Lambert Beer's law, the national environmental standard of the People's Republic of China "Determination of Ozone in Environmental Air - Ultraviolet Method", and the verification and calibration methods of the Ministry of Construction of the People's Republic of China "Ozone Generator for Water Treatment". By measuring the changes in light signal intensity before and after the absorption of ultraviolet light by ozone, the current ozone concentration value can be calculated. The equipment uses an advanced dual path ultraviolet light source system, which is equipped with an intelligent management system for the lamp tube. After turning on, the ultraviolet lamp tube can quickly reach the measurement state. It adopts foreign separated light cell technology and has the characteristics of no leakage, high pressure resistance, high flow sampling gas impact resistance, easy cleaning, convenient maintenance, simple operation, and low usage cost.

The equipment automatically cleans the zero point every certain time to ensure the stability of the zero point and prevent zero drift from affecting the accuracy of concentration detection. The gas flow rate, pressure, and flow velocity during zero calibration remain unchanged to prevent the impact of airflow on zero calibration and ensure that the equipment can operate continuously 24 hours a day.

Application fields: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry, food and drinking water industry, space disinfection industry, swimming pool disinfection industry, essence synthesis industry and other industries using ozone generators.


3、 Product Technical Features

test method

Dual path ultraviolet absorption method, long-life light source system, high measurement accuracy.

Measuring principle

According to Lambert Beer's law, accurate measurement is achieved through the principle of photometric absorption.

light source system

The overseas long-life ultraviolet light source system (wavelength 253.7nm) comes with a 3-year free warranty.

Usage method

Indoor installation and use, equipped with power and signal terminals.

Light pool system

Separated light cell technology, leak free, high pressure resistant, and resistant to high flow sampling gas impact.

Intelligent compensation

Built in temperature and pressure compensation and display, with automatic light source compensation function.

Operation method

Users can choose between manual zeroing and automatic zeroing based on the operating status, and can set the automatic zeroing time.

display unit

High definition color touch screen, high concentration range setting for gas mass flow rate, real-time display of production output.

The data shows

g/Nm3,mg/NL,%WT,ppm,mg/Nm3 可选。

output function

4-20mA, RS485 communication, two sets of alarm point outputs, electronic flowmeter input, etc.

Standard Configuration

Anti corrosion flowmeter, ozone exhaust disruptor, intake filter.


2、 Technical parameters

Range: 0-200g/m3NTP (optional ranges: 0-100g/m3, 0-200g/m3, 0-250g/m3);

Display resolution: 0.01 g/m3;

Gas flow rate: 0.8L ± 0.2L/min;

Input pressure:<0.1MPa;

Zero drift:<± 0.3% FS(MAX:±0.6g/m3);

Sampling port diameter: Φ 6 (6mm * 4mm);

Error rate: ± 0.5%;

Communication method: RS-485;

Output mode: 4-20mA, linear;

Power supply: AC 110-220V;

Size: 155 * 68 * 240mm; 22cm × 15.5cm × 7.8cm

Hole size: 145 * 68; (Can be embedded for installation);

注: 1mg/L=1g/m3=467PPM;

Free warranty: 24 months (host);

Note: Standard configuration: Embedded card. Optional configuration: anti-corrosion flowmeter (with flowmeter bracket), ozone exhaust catalyst.


3、 Product features:

Measurement principle: Based on Lambert Beer's law, precise measurement is achieved through the principle of photometric absorption;

Testing method: Dual path ultraviolet absorption method, with high measurement accuracy;

Light source system: imported long-life ultraviolet lamp tube (wavelength 253.7nm);

Usage: Indoor installation, capable of 24-hour continuous operation, equipped with power and signal connectors;

Light cell system: Foreign separated light cell technology, leak free, high pressure resistant, and resistant to high flow sampling gas impact;

Intelligent compensation: built-in light source automatic compensation function;

Automatic zeroing: The equipment automatically zeros once every certain time, and can choose manual automatic mode to ensure the accuracy of concentration detection.

Data display: High definition digital backlight display, clear and countable data;

Output function: 4-20mA current signal, RS485 communication;

1. Usage conditions:

This ozone gas concentration analyzer is designed for indoor wall mounted installation and enters working mode upon startup. It is recommended to preheat for 5 minutes and calibrate once before use. Can be used continuously online 24 hours a day, pay attention to the safety of power supply and environmental conditions when using.

This machine is equipped with a UV LED light source monitoring system, and occasional zero deviation situations may occur, which can be ignored. The system will adjust according to the brightness of the light source. If there is a zero deviation without ozone, manual zero calibration can be performed to clear it.

2. Precautions:

(1) This ozone analyzer is designed for indoor installation and should be used in a well ventilated, dry, and non corrosive environment. Special attention should be paid to isolating or protecting instruments in a timely manner if there are gases such as ammonia, hydrogen chloride, hydrogen sulfide, etc. in the environment. Gases can corrode circuit boards and touch screens, and ozone gas concentration analyzers cannot function properly. The malfunction of the instrument caused by this situation is not covered by the free warranty.

(2) It is necessary to ensure that the ozone gas entering is clean and dry. If it is necessary to detect the concentration of ozone gas in damp areas or with dust, a filtering device (flue gas filter) and a dehumidification device (electronic condenser) must be installed on the inlet of the ozone gas concentration analyzer. The malfunction of the instrument caused by this situation is not covered by the free warranty.

(3) It is strictly prohibited to directly introduce ozone gas containing substances such as oil, water mist, dust, etc. into the ozone gas analyzer. A pre-treatment device must be installed at the front end of the inlet. The malfunction of the instrument caused by this situation is not covered by the free warranty.

(4) It is strictly prohibited to connect the outlet of the exhaust gas disruptor back to the main pipeline (according to the "Ozone Generator for Water Treatment" standard of the Ministry of Construction, the exhaust gas from the outlet of the ozone concentration analyzer must be discharged or a destructive device must be installed).

(5) If the ozone analyzer is not used for a long time, it is necessary to regularly turn on the heating machine and store the instrument in a moisture-proof manner.

(6) The exhaust disruptor may generate heat during operation. It is strictly prohibited to touch it directly with hands (be careful of burns). Pay attention to the fact that the exhaust disruptor may become ineffective if it is damp. When not in use for a long time, moisture-proof measures should be taken. If ozone gas is found to overflow from the outlet of the exhaust disruptor, please contact the manufacturer in a timely manner to purchase replacement.

(7) Please use the polytetrafluoroethylene connecting pipe provided by the manufacturer for the intake connection of the ozone gas concentration analyzer. It is strictly prohibited to use connecting pipes that are not resistant to ozone corrosion, such as PU and silicone.

(8) The intake filter configured by the manufacturer can only filter dust particles and cannot filter media such as oil mist and water mist. If users need to detect ozone gas with media such as oil mist and water mist, please contact the manufacturer in a timely manner and customize a pre-treatment device.

Shandong Zhipu Measurement and Control Technology Co., Ltd. After sales Service Commitment

1. Shandong Zhipu Measurement and Control Technology Co., Ltd. makes a product quality commitment to the analyzer produced by our company. The premise of making this commitment is to use and repair the analyzer under normal operating conditions. The free warranty period is 12 months (12 months from the delivery of the analyzer to the customer). If it exceeds 12 months, replacement and maintenance parts will be charged a certain fee according to the fault maintenance and repair standards.

2. Shandong Zhipu Measurement and Control Technology Co., Ltd. implements a free calibration system for the instruments and meters sold. It is recommended that users return the ozone analyzer products for factory calibration every 12 months (online use) or 18 months (experimental use) for free calibration, and users bear the round-trip shipping costs.

3. The maintenance or replacement of faulty parts is the obligation undertaken by Shandong Zhipu Measurement and Control Technology Co., Ltd. in this commitment; Under no circumstances can the buyer unilaterally terminate the sales agreement or request compensation for losses caused by the identified faulty components, or for losses caused by the work done by Shandong Zhipu Measurement and Control Technology Co., Ltd. in accordance with this commitment.

4. Shandong Zhipu Measurement and Control Technology Co., Ltd. refuses to assume any responsibility for any losses caused by accidents, theft, illegal entry, dismantling, misappropriation, fires or other unforeseeable force majeure events caused by climate.

The after-sales service commitment of Shandong Zhipu Measurement and Control Technology Co., Ltd. does not include the following points:

1. Normal maintenance and material wear and tear.

2. Color changes or fading due to normal wear and tear, abnormal operating conditions, or harsh weather conditions.

3. Claims for expenses incurred due to transporting the analyzer to the authorized service center of Shandong Zhipu Measurement and Control Technology Co., Ltd., or claims for compensation for direct or indirect losses caused by repairing the analyzer, including transportation, accommodation, and telephone expenses, etc.

4. The abnormality of the analyzer is not due to material or structural defects, but rather due to improper use of the analyzer, neglect of maintenance, accidents, or lack of repair.

If the following situations occur, the commitment is invalid:

The repair operation recommended by the manufacturer was not carried out at Shandong Zhipu Measurement and Control Technology Co., Ltd. or an authorized service center of Shandong Zhipu Measurement and Control Technology Co., Ltd.

2. The analyzer or part of the analyzer is not being repaired, modified, or disassembled at a location.

3. Neglecting maintenance of the analyzer or using the analyzer incorrectly.

4. After modification, the mechanical and electronic components of the analyzer or its system obstruct, even partially, the normal operating conditions provided by Shandong Zhipu Measurement and Control Technology Co., Ltd.

Warning: In order to effectively implement this commitment, customers must go to Shandong Zhipu Measurement and Control Technology Co., Ltd. or authorized service centers of Party A for repairs. The materials replaced during the commitment period belong to Shandong Zhipu Measurement and Control Technology Co., Ltd.


Shandong Zhipu Measurement and Control Technology Co., Ltd