Explosion proof oxygen O2 concentration detection tube gas detector oxygen meter
It adopts the advanced management philosophy and system of Japan's Gastec Cor cooperation, and accepts the entrustment of Japan's Gastec Company to take full charge of the sales business of its original products in Chinese Mainland. Beijing Kesite Gas Technology Co., Ltd. provides gas generators, permeation tubes, gas samplers, gas detection tubes and other products and services to a wide range of domestic customers, including Tsinghua University Yangtze River Delta Research Institute, Philips Research Institute, Coca Cola Company, Agilent, Centers for Disease Control and Prevention (CDC), environmental monitoring agencies, research institutions, etc. It has gained recognition from customers and established good cooperation.
It adopts the advanced management philosophy and system of Japan's Gastec Cor cooperation, and accepts the entrustment of Japan's Gastec Company to take full charge of the sales business of its original products in Chinese Mainland. Beijing Kesite Gas Technology Co., Ltd. provides gas generators, permeation tubes, gas samplers, gas detection tubes and other products and services to a wide range of domestic customers, including Tsinghua University Yangtze River Delta Research Institute, Philips Research Institute, Coca Cola Company, Agilent, Centers for Disease Control and Prevention (CDC), environmental monitoring agencies, research institutions, etc. It has gained recognition from customers and established good cooperation.
Oxygen detection tube O2
The oxygen detection tube is a sealed, slender glass tube that presents a specific color due to being filled with specific reagents and coloring agents. When a gas sample containing oxygen enters the detection tube, a chemical change occurs, causing a change in color. The scale corresponding to the boundary of observing color changes is the concentration of oxygen in the tested sample.
31B specification:
| Testing Scope | 3-6% | 6-24% | |
| Extraction frequency | Once (100ml) | 1/2 time (standard) (50ml) | |
| correction factor | 1/2 | 1 | |
| pumping time | 2 minutes | 1 minute |
Testing line: 2% (extraction once)
Color Change: Black White
Temperature and humidity correction: No temperature correction required
Relative standard deviation: 5% (6-24%)
Validity period: 36 months
reaction principle:O2+4TiCl3+6H2O4TiO2+12HCl