Explosion proof isopropyl alcohol IPA concentration gas detection tube detector toxic tube
Isopropanol detection tube CH3CH(OH)CH3
The isopropanol detection tube is a sealed, slender glass tube that presents a specific color due to being filled with specific reagents and coloring agents. When a gas sample containing isopropanol enters the detection tube, a chemical change occurs, causing a change in color. The scale corresponding to the boundary of color change observation is the concentration of isopropanol in the tested sample.
113 specification:
| Testing Scope | 0.02-0.04% | 0.04-2.5% | 2.5-5% |
| Extraction frequency | 2 times (200ml) | 1 time (standard) (100ml) | 1/2 time (50ml) |
| correction factor | 1/2 | 1 | 2 |
| Detection Time | 2 minutes | 1 minute | 30 seconds |
Testing line: 0.004% (2 extractions)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Relative standard deviation: 15% (0.04-0.5%), 10% (0.5-2.5%)
Validity period: 36 months
reaction principle:CH3CH(OH)CH3+Cr6+(Light red)+H2SO4Cr3+(Light Blue)
Other gases that can be detected by this detection tube:
| gas name | conversion factor | Extraction frequency | Testing Scope |
| propanol | 1 | 1 | 0.04-2.5% |
113L specification:
| Testing Scope | 20-50ppm | 50-800ppm |
| Extraction frequency | 2 times (200ml) | 1 time (standard) (100ml) |
| coefficient | 0.4 | 1 |
| Detection Time | 4 points | 2 points |
Detection line: 15ppm (pumping twice)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Validity period: 36 months
reaction principle:CH3CH(OH)CH3+Cr6+(Light red)+H2SO4Cr3+(Light Blue)
113LL specification:
| Testing Scope | 20-200ppm | 200-460ppm |
| Extraction frequency | 2 times (standard) (200ml) | Once (100ml) |
| coefficient | 1 | 2.3 |
| Detection Time | 4 points | 2 points |
Detection line: 7ppm (2 extractions)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Validity period: 24 months
reaction principle:CH3CH(OH)CH3+Cr6+(Light red)+H2SO4Cr3+(Light Blue)
113TP specification:
| Testing Scope | 20-200ppm | 200-400ppm |
| Flow setting | 100ml/min(1000ml) | 50ml/min(500ml) |
| correction factor | 1 | 2 |
| Detection Time | 10 points | 10 points |
Testing line: 5ppm (1000ml)
Color change: light red, light blue
Temperature and humidity correction: Temperature correction is required
Validity period: 24 months
Reaction principle: CH3CH(OH)CH3+ Cr6++ H2SO4Cr3+

Explosion proof isopropyl alcohol IPA concentration gas detection tube detector toxic tube