Specifications
|
EHC-09 / TT900
|
|
thickness range
|
0.75mm-508mm
|
√
|
|
Zero point measurement of delay line
|
Very suitable for automatic correction of delay line bending and sensor acoustic drift under high temperature conditions
|
√
|
|
scanning mode
|
Display the * small or * large thickness values in 20 measurements per second
|
√
|
|
Maintain mode
|
Keep the thickness data displayed on the monitor after *
|
√
|
|
freeze mode
|
Freeze display
|
√
|
|
Unit
|
Imperial/Metric/Microseconds
|
√
|
|
Gain
|
Low/Standard/High, available for changing detection conditions selection
|
√
|
|
Difference mode
|
Display the difference between the actual measured value and the health standard value
|
√
|
|
alarm method
|
Extreme value alarm, vibration alarm, beep alarm, flashing display screen and illuminated keyboard alarm
|
√
|
|
Luminous keyboard
|
F1- Red, the measured value exceeds the extreme range; F2- Yellow, the measured value is close to the extreme value;
F3=green, the value to be measured is within the measurement range, very suitable for measurement (* *)
|
√
|
|
Probe wear automatic indicator
|
Automatically inform the operator to replace the sensor (* *)
|
√
|
|
Echo echo mode
|
Only measure metal thickness (without considering the influence of paint and coating)
|
√
|
|
Size
|
127mm(L)×76.2mm(W)×31.75mm(H)
|
|
Weight
|
0.23kg
|
|
Thickness measurement range
|
0.75mm-508mm, Depending on the material to be inspected, temperature, and selected sensor
|
|
Sound speed range
|
508-18699m/S
|
|
Temperature
|
Working temperature of thickness gauge: -20 ℃~50 ℃
|
|
Surface temperature of the material to be inspected
|
-20 ℃ to 537 ℃ (depending on the probe used)
|
|
battery life
|
200 hours (40 hours when backlit)
|
|
Battery Type
|
2 AA alkaline batteries
|
|
display
|
Black and white LCD display, 128 × 64 image
|
|
display information
|
Signal attenuation, * large value, * small value, displaying both large and small readings, measuring rate, zero point, calibration, units, frozen mode, unfrozen mode, remaining battery, gain low/standard/high, echo echo measurement mode
|
|
resolution
|
0.01mm,0.1mm
|
|
Probe recognition
|
Select from the menu list
|
|
Instrument appearance
|
Specially designed waterproof, oil resistant, and high impact plastic casing with illuminated keyboard indicating measurable/unmeasurable functions
|
|
Frequency bandwidth
|
0.5-20MHz(-3dB)
|
|
Unit
|
Imperial/Metric/Microseconds
|
|
Gain
|
Low/Standard/High, available for changing detection conditions selection
|
|
Difference mode
|
The user inputs the standard thickness value for reference, and the instrument displays the difference between the actual measured value and the standard value
|
|
alarm method
|
Extreme value alarm, vibration alarm, beep alarm, flashing display screen and illuminated keyboard alarm
|
|
Luminous keyboard
|
F1=red, the measured value exceeds the extreme range; F2=yellow, the measured value is close to the extreme value; F3=green, the value to be measured is within the measurement range, very suitable for measurement (* *)
|
|
Measurement rate
|
4 times/second, fast measurement mode (scanning mode): 20 times/second
|
|
user-friendly design
|
Through the keyboard, users can switch between left/right display (* *)
|
|
Backlight display
|
Light emitting diode, automatically turns on backlight display through On/Off switch, or based on valid data or last button press
|
|
Close
|
Time limited automatic shutdown function (users can program and design it themselves: the instrument will automatically shut down after a few minutes without reading, signal attenuation, or buttons)
|
|
scanning mode
|
It can display * small or * large thickness values from 20 measurements per second, which is very suitable for reading and tracking * small thickness alarm values in high-temperature situations. Before signal attenuation, press the freeze mode to capture the final effective small thickness value, which is not affected by the coupling agent covering the probe when it leaves the sample
|
|
freeze mode
|
Freeze display
|
|
Maintain mode
|
Keep the thickness data displayed on the monitor after *
|