Electronic remote water meter (photoelectric direct reading) LXSG-15~25

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Product model: LXSG-15~25 Product introduction: The water meter adopts photoelectric direct reading technology to read character wheel data. Compared with traditional pulse remote transmission meters and plug-in pulse meters, it can reduce the reading error to zero. It is an intelligent remote transmission water meter that achieves zero error through electromechanical conversion in automatic meter reading systems. The module adopts a low-power design and usually does not require power supply. It is only powered through the meter reading bus during meter reading or valve operation. The meters and collection devices are connected by M-bus or RS-485 bus, and are intelligent instruments for remote intelligent reading, data transmission, and valve opening and closing, achieving automated and intelligent management.

Product Details

Functional Features
  • Accurate reading

    The photoelectric direct reading technology is used to read the data of the character wheel, and the data read at any time is consistent with the mechanical character wheel reading of the water meter.

  • long service life

    Using photoelectric sensing technology for sampling, there is no mechanical contact or action, and it is not affected by vibrations caused by pipelines or other factors that may cause malfunctions.

  • Use safety

    The meter adopts weak current line communication. The strong electric power supply is physically isolated from the water meter, with high insulation strength to ensure safe use.

  • Easy installation

    The basic meter part of the direct reading water meter has the same installation specifications as ordinary mechanical water meters, making installation simple.

  • Unique signal acquisition

    Using photoelectric sensing technology, the window reading is directly read to ensure accurate data acquisition.

  • energy conservation

    The module adopts a low-power design, which only requires power supply for reading and valve operation, and will not lose data due to power outages or network failures.

  • Data Communication Specification

    Cooperate with the collector or concentrator to upload data in accordance with CJ/T188 "Technical Conditions for Data Transmission of Household Measuring Instruments"DL/T645 "Multi functional Energy Meter Communication Protocol" and Modbus RTU Communication Protocol.


Model Function Comparison Table
Model selection caliber function code function
LXSG-15~25 DN15、DN20、DN25 ZT Photoelectric direct reading water meter (cold water, RS485)
RZT Photoelectric direct reading water meter (hot water, RS485)
ZCT Photoelectric direct reading water meter (cold water, with valve control, RS485)
RZCT Photoelectric direct reading water meter (hot water, with valve control, RS485)
ZM Photoelectric direct reading water meter (cold water, M-BUS)
RZM Photoelectric direct reading water meter (hot water, M-BUS)
ZCM Photoelectric direct reading water meter (cold water, with valve control, M-BUS)
RZCM Photoelectric direct reading water meter (hot water, with valve control, M-BUS)


Example: LXSG-15 ZCT represents DN15 caliber, cold water, photoelectric direct reading, with valve control RS485。

LXSG-15 RZCT stands for DN15 caliber, with hot water, photoelectric direct reading, and valve control RS485。


Technical parameters
Nominal diameter DN (mm) 15 20 25
Overload flow Q4 (m ³/h) 3.125 5.0 7.875
Common flow rate Q3 (m ³/h) 2.5 4.0 6.3
R=Q3/Q1 80, 100, 125, 160 (optional)
Range ratio Q2/Q1=1.6 Q4/Q3=1.25
unit of measurement Cubic meter (m ³) or liter (L)
ambient temperature -15°C~55°C
Ambient relative humidity <90%.
ambient humidity (0-95)%RH
Temperature rating Cold water T30, hot water T90
environmental rating Grade B
Electromagnetic environment level E1 level
accuracy class level 2
water pressure ≤1.0Mpa
water quality Tap water, direct drinking water, domestic hot water
Working power supply DC 12V
Power consumption parameters Test voltage 3.6V
communication interface RS485/M-BUS (optional)
Display mode Mechanical cumulative display, network remote display
Communication transmission rate 1200~9600 bps
Maximum distance for communication transmission 1200m




Installation size
Product Category

Nominal diameter

DN

(mm)

long wide tall High 1 Connecting thread
L B H H1 G
Mm tolerance: ± 1
Horizontal water meter
15 165 90 120 185 G3/4B
20 195 90 120 185 G1B
25 225 90 120 185 G11/4B
Vertical water meter 15 96 137 108 170 G3/4B
20 100 146 110 180 G1B
25 150 171 131 200 G11/4B
Horizontal valve controlled water meter 15 165 90 116
G3/4B
20 195 90 116
G1B
25 225 90 120
G11/4B



水平式水表外形尺寸图.png

Outline dimension diagram of horizontal water meter



水平式阀控水表外形尺寸图.png


Outline dimension diagram of horizontal valve controlled water meter


立式水表外形尺寸图.png

Outline dimension diagram of vertical water meter



The product meets the standards

GB/T 778-2018 "Drinking Cold Water Meter and Hot Water Meter"

CJ/T 224-2012 "Electronic Remote Water Meter"

CJ/T 383-2011 "Electronic Direct Reading Water Meter"

JJG 162-2019 "Verification Regulations for Drinking Cold Water Meters"

JJG 686-2015 "Verification Regulations for Hot Water Meters"

CJ/T 188 "Technical Conditions for Data Transmission of Household Measuring Instruments"

DL/T 645 "Communication Protocol for Multi functional Energy Meters"

Modbus RTU communication protocol