| Functional Features |
Accurate reading
The photoelectric direct reading technology is used to read the data of the character wheel, and the data read at any time is consistent with the mechanical character wheel reading of the water meter.
long service life
Using photoelectric sensing technology for sampling, there is no mechanical contact or action, and it is not affected by vibrations caused by pipelines or other factors that may cause malfunctions.
Use safety
The meter adopts weak current line communication. The strong electric power supply is physically isolated from the water meter, with high insulation strength to ensure safe use.
Easy installation
The basic meter part of the direct reading water meter has the same installation specifications as ordinary mechanical water meters, making installation simple.
Unique signal acquisition
Using photoelectric sensing technology, the window reading is directly read to ensure accurate data acquisition.
energy conservation
The module adopts a low-power design, which only requires power supply for reading and valve operation, and will not lose data due to power outages or network failures.
Data Communication Specification
Cooperate with the collector or concentrator to upload data in accordance with CJ/T188 "Technical Conditions for Data Transmission of Household Measuring Instruments"DL/T645 "Multi functional Energy Meter Communication Protocol" and Modbus RTU Communication Protocol.
|
Model Function Comparison Table |
| Model selection | caliber | function code | function |
| LXSG-15~25 | DN15、DN20、DN25 | ZT | Photoelectric direct reading water meter (cold water, RS485) |
| RZT | Photoelectric direct reading water meter (hot water, RS485) | ||
| ZCT | Photoelectric direct reading water meter (cold water, with valve control, RS485) | ||
| RZCT | Photoelectric direct reading water meter (hot water, with valve control, RS485) | ||
| ZM | Photoelectric direct reading water meter (cold water, M-BUS) | ||
| RZM | Photoelectric direct reading water meter (hot water, M-BUS) | ||
| ZCM | Photoelectric direct reading water meter (cold water, with valve control, M-BUS) | ||
| RZCM | Photoelectric direct reading water meter (hot water, with valve control, M-BUS) |
Example: LXSG-15 ZCT represents DN15 caliber, cold water, photoelectric direct reading, with valve control RS485。
LXSG-15 RZCT stands for DN15 caliber, with hot water, photoelectric direct reading, and valve control RS485。
|
Technical parameters |
| Nominal diameter DN (mm) | 15 | 20 | 25 |
| Overload flow Q4 (m ³/h) | 3.125 | 5.0 | 7.875 |
| Common flow rate Q3 (m ³/h) | 2.5 | 4.0 | 6.3 |
| R=Q3/Q1 | 80, 100, 125, 160 (optional) | ||
| Range ratio | Q2/Q1=1.6 Q4/Q3=1.25 | ||
| unit of measurement | Cubic meter (m ³) or liter (L) | ||
| ambient temperature | -15°C~55°C | ||
| Ambient relative humidity | <90%. | ||
| ambient humidity | (0-95)%RH | ||
| Temperature rating | Cold water T30, hot water T90 | ||
| environmental rating | Grade B | ||
| Electromagnetic environment level | E1 level | ||
| accuracy class | level 2 | ||
| water pressure | ≤1.0Mpa | ||
| water quality | Tap water, direct drinking water, domestic hot water | ||
| Working power supply | DC 12V | ||
| Power consumption parameters | Test voltage 3.6V | ||
| communication interface | RS485/M-BUS (optional) | ||
| Display mode | Mechanical cumulative display, network remote display | ||
| Communication transmission rate | 1200~9600 bps | ||
| Maximum distance for communication transmission | 1200m | ||
| Installation size |
| Product Category |
Nominal diameter DN (mm) |
long | wide | tall | High 1 | Connecting thread |
| L | B | H | H1 | G | ||
| Mm tolerance: ± 1 | ||||||
| Horizontal water meter |
15 | 165 | 90 | 120 | 185 | G3/4B |
| 20 | 195 | 90 | 120 | 185 | G1B | |
| 25 | 225 | 90 | 120 | 185 | G11/4B | |
| Vertical water meter | 15 | 96 | 137 | 108 | 170 | G3/4B |
| 20 | 100 | 146 | 110 | 180 | G1B | |
| 25 | 150 | 171 | 131 | 200 | G11/4B | |
| Horizontal valve controlled water meter | 15 | 165 | 90 | 116 | G3/4B | |
| 20 | 195 | 90 | 116 | G1B | ||
| 25 | 225 | 90 | 120 | G11/4B | ||

Outline dimension diagram of horizontal water meter

Outline dimension diagram of horizontal valve controlled water meter

Outline dimension diagram of vertical water meter
| The product meets the standards |
GB/T 778-2018 "Drinking Cold Water Meter and Hot Water Meter"
CJ/T 224-2012 "Electronic Remote Water Meter"
CJ/T 383-2011 "Electronic Direct Reading Water Meter"
JJG 162-2019 "Verification Regulations for Drinking Cold Water Meters"
JJG 686-2015 "Verification Regulations for Hot Water Meters"
CJ/T 188 "Technical Conditions for Data Transmission of Household Measuring Instruments"
DL/T 645 "Communication Protocol for Multi functional Energy Meters"
Modbus RTU communication protocol